35 resultados para Conduction
Resumo:
Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model’s linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.
Resumo:
INTRODUCTION The aim of this study was to compare orthodromic sural nerve conduction study (NCS) results using ultrasound-guided needle positioning (USNP) to surface electrode recordings. METHODS 51 healthy subjects aged 24 - 80 years, divided into 5 age groups, were examined. Electrical stimuli were applied behind the lateral malleolus. Sensory nerve action potentials (SNAPs) were recorded 8 and 15 cm proximally with surface and needle electrodes. RESULTS Mean SNAP amplitudes in µV (surface/needle electrodes) averaged 12.7 (SD 7.6)/40.6 (SD 20.8), P<0.001, for subjects aged 20-29 years, and 5.0 (SD 2.4)/19.8 (SD 9.8), P<0.01, for subjects aged > 60 years. SNAP amplitudes were smaller at the proximal recording location. DISCUSSION NCS using USNP yield higher amplitude responses than surface electrodes in all age groups at all recording sites. SNAP amplitudes are smaller at proximal recording locations due to sural nerve branching. This article is protected by copyright. All rights reserved.
Resumo:
BACKGROUND Mapping to identify scar-related ventricular tachycardia re-entry circuits during sinus rhythm focuses on sites with abnormal electrograms or pace-mapping findings of QRS morphology and long stimulus to QRS intervals. We hypothesized that (1) these methods do not necessarily identify the same sites and (2) some electrograms are far-field potentials that can be recognized by pacing. METHODS AND RESULTS From 12 patients with coronary disease and recurrent ventricular tachycardia undergoing catheter ablation, we retrospectively analyzed electrograms and pacing at 546 separate low bipolar voltage (<1.5 mV) sites. Electrograms were characterized as showing evidence of slow conduction if late potentials (56%) or fractionated potentials (76%) were present. Neither was present at (13%) sites. Pacing from the ablation catheter captured 70% of all electrograms. Higher bipolar voltage and fractionation were independent predictors for pace capture. There was a linear correlation between the stimulus to QRS duration during pacing and the lateness of a capturing electrogram (P<0.001), but electrogram and pacing markers of slow conduction were discordant at 40% of sites. Sites with far-field potentials, defined as those that remained visible and not captured by pacing stimuli, were identified at 48% of all pacing sites, especially in areas of low bipolar voltage and late potentials. Initial radiofrequency energy application rendered 74% of targeted sites electrically unexcitable. CONCLUSIONS Far-field potentials are common in scar areas. Combining analysis of electrogram characteristics and assessment of pace capture may refine identification of substrate targets for radiofrequency ablation.
Resumo:
BACKGROUND Arrhythmias in cardiac amyloidosis (CA) result in significant comorbidity and mortality but have not been well characterized. OBJECTIVE The purpose of this study was to define intracardiac conduction, atrial arrhythmia substrate, and ablation outcomes in a group of advanced CA patients referred for electrophysiologic study. METHODS Electrophysiologic study with or without catheter ablation was performed in 18 CA patients. Findings and catheter ablation outcomes were compared to age- and gender-matched non-CA patients undergoing catheter ablation of persistent atrial fibrillation (AF). RESULTS Supraventricular tachycardias were seen in all 18 CA patients (1 AV nodal reentrant tachycardia, 17 persistent atrial tachycardia [AT]/AF). The HV interval was prolonged (>55 ms) in all CA patients, including 6 with normal QRS duration (≤100 ms). Thirteen supraventricular tachycardia ablations were performed in 11 patients. Of these, 7 underwent left atrial (LA) mapping and ablation for persistent AT/AF. Compared to non-CA age-matched comparator AF patients, CA patients had more extensive areas of low-voltage areas LA (63% ± 22% vs 34% ± 22%, P = .009) and a greater number of inducible ATs (3.3 ± 1.9 ATs vs 0.2 ± 0.4 ATs, P <.001). The recurrence rate for AT/AF 1 year after ablation was greater in CA patients (83% vs 25%), and the hazard ratio for postablation AT/AF recurrence in CA patients was 5.4 (95% confidence interval 1.9-35.5, P = .007). CONCLUSION In this group of patients with advanced CA and atrial arrhythmias, there was extensive conduction system disease and LA endocardial voltage abnormality. Catheter ablation persistent AT/AF in advanced CA was associated with a high recurrence rate and appears to have a limited role in control of these arrhythmias.