42 resultados para Computer-Based Training System


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Accurate needle placement is crucial for the success of percutaneous radiological needle interventions. We compared three guiding methods using an optical-based navigation system: freehand, using a stereotactic aiming device and active depth control, and using a stereotactic aiming device and passive depth control. METHODS For each method, 25 punctures were performed on a non-rigid phantom. Five 1 mm metal screws were used as targets. Time requirements were recorded, and target positioning errors (TPE) were measured on control scans as the distance between needle tip and target. RESULTS Time requirements were reduced using the aiming device and passive depth control. The Euclidian TPE was similar for each method (4.6 ± 1.2-4.9 ± 1.7 mm). However, the lateral component was significantly lower when an aiming device was used (2.3 ± 1.3-2.8 ± 1.6 mm with an aiming device vs 4.2 ± 2.0 mm without). DISCUSSION Using an aiming device may increase the lateral accuracy of navigated needle insertion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diversity of European culture is reflected in its healthcare training programs. In intensive care medicine (ICM), the differences in national training programs were so marked that it was unlikely that they could produce specialists of equivalent skills. The Competency-Based Training in Intensive Care Medicine in Europe (CoBaTrICE) program was established in 2003 as a Europe-based worldwide collaboration of national training organizations to create core competencies for ICM using consensus methodologies to establish common ground. The group's professional and research ethos created a social identity that facilitated change. The program was easily adaptable to different training structures and incorporated the voice of patients and relatives. The CoBaTrICE program has now been adopted by 15 European countries, with another 12 countries planning to adopt the training program, and is currently available in nine languages, including English. ICM is now recognized as a primary specialty in Spain, Switzerland, and the UK. There are still wide variations in structures and processes of training in ICM across Europe, although there has been agreement on a set of common program standards. The combination of a common "product specification" for an intensivist, combined with persisting variation in the educational context in which competencies are delivered, provides a rich source of research inquiry. Pedagogic research in ICM could usefully focus on the interplay between educational interventions, healthcare systems and delivery, and patient outcomes, such as including whether competency-based program are associated with lower error rates, whether communication skills training is associated with greater patient and family satisfaction, how multisource feedback might best be used to improve reflective learning and teamworking, or whether increasing the proportion of specialists trained in acute care in the hospital at weekends results in better patient outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The partial shift from patient to model is a reasonable and necessary paradigm shift in surgery in order to increase patient safety and to adapt to the reduced training time periods in hospitals and increased quality demands. Since 1991 the Vascular International Foundation and School has carried out many training courses with more than 2,500 participants. The modular build training system allows to teach many open vascular and endovascular surgical techniques on lifelike models with a pulsatile circulation. The simulation courses cannot replace training in operating rooms but are suitable for supporting the cognitive and associative stages for achieving motor skills. Scientific evaluation of the courses has continually shown that the training principle established since 1991 can lead to significant learning success. They are extremely useful not only for beginners but also for experienced vascular surgeons. They can help to shorten the learning curve, to learn new techniques or to refine previously used techniques in all stages of professional development. Keywords Advanced training · Advanced training regulations · Training model · Vascular International · Certification

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To develop a behavioural observation method to simultaneously assess distractors and communication/teamwork during surgical procedures through direct, on-site observations; to establish the reliability of the method for long (>3 h) procedures. METHODS: Observational categories for an event-based coding system were developed based on expert interviews, observations and a literature review. Using Cohen's κ and the intraclass correlation coefficient, interobserver agreement was assessed for 29 procedures. Agreement was calculated for the entire surgery, and for the 1st hour. In addition, interobserver agreement was assessed between two tired observers and between a tired and a non-tired observer after 3 h of surgery. RESULTS: The observational system has five codes for distractors (door openings, noise distractors, technical distractors, side conversations and interruptions), eight codes for communication/teamwork (case-relevant communication, teaching, leadership, problem solving, case-irrelevant communication, laughter, tension and communication with external visitors) and five contextual codes (incision, last stitch, personnel changes in the sterile team, location changes around the table and incidents). Based on 5-min intervals, Cohen's κ was good to excellent for distractors (0.74-0.98) and for communication/teamwork (0.70-1). Based on frequency counts, intraclass correlation coefficient was excellent for distractors (0.86-0.99) and good to excellent for communication/teamwork (0.45-0.99). After 3 h of surgery, Cohen's κ was 0.78-0.93 for distractors, and 0.79-1 for communication/teamwork. DISCUSSION: The observational method developed allows a single observer to simultaneously assess distractors and communication/teamwork. Even for long procedures, high interobserver agreement can be achieved. Data collected with this method allow for investigating separate or combined effects of distractions and communication/teamwork on surgical performance and patient outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presented approach describes a model for a rule-based expert system calculating the temporal variability of the release of wet snow avalanches, using the assumption of avalanche triggering without the loading of new snow. The knowledge base of the model is created by using investigations on the system behaviour of wet snow avalanches in the Italian Ortles Alps, and is represented by a fuzzy logic rule-base. Input parameters of the expert system are numerical and linguistic variables, measurable meteorological and topographical factors and observable characteristics of the snow cover. Output of the inference method is the quantified release disposition for wet snow avalanches. Combining topographical parameters and the spatial interpolation of the calculated release disposition a hazard index map is dynamically generated. Furthermore, the spatial and temporal variability of damage potential on roads exposed to wet snow avalanches can be quantified, expressed by the number of persons at risk. The application of the rule base to the available data in the study area generated plausible results. The study demonstrates the potential for the application of expert systems and fuzzy logic in the field of natural hazard monitoring and risk management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapidly growing technical developments and working time constraints call for changes in trainee formation. In reality, trainees spend fewer hours in the hospital and face more difficulties in acquiring the required qualifications in order to work independently as a specialist. Simulation-based training is a potential solution. It offers the possibility to learn basic technical skills, repeatedly perform key steps in procedures and simulate challenging scenarios in team training. Patients are not at risk and learning curves can be shortened. Advanced learners are able to train rare complications. Senior faculty member's presence is key to assess and debrief effective simulation training. In the field of vascular access surgery, simulation models are available for open as well as endovascular procedures. In this narrative review, we describe the theory of simulation, present simulation models in vascular (access) surgery, discuss the possible benefits for patient safety and the difficulties of implementing simulation in training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. PATIENTS, MATERIAL AND METHODS 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. RESULTS Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. CONCLUSIONS SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The biased interpretation of ambiguous social situations is considered a maintaining factor of Social Anxiety Disorder (SAD). Studies on the modification of interpretation bias have shown promising results in laboratory settings. The present study aims at pilot-testing an Internet-based training that targets interpretation and judgmental bias. METHOD: Thirty-nine individuals meeting diagnostic criteria for SAD participated in an 8-week, unguided program. Participants were presented with ambiguous social situations, were asked to choose between neutral, positive, and negative interpretations, and were required to evaluate costs of potential negative outcomes. Participants received elaborate automated feedback on their interpretations and judgments. RESULTS: There was a pre-to-post-reduction of the targeted cognitive processing biases (d = 0.57-0.77) and of social anxiety symptoms (d = 0.87). Furthermore, results showed changes in depression and general psychopathology (d = 0.47-0.75). Decreases in cognitive biases and symptom changes did not correlate. The results held stable accounting for drop-outs (26%) and over a 6-week follow-up period. Forty-five percent of the completer sample showed clinical significant change and almost half of the participants (48%) no longer met diagnostic criteria for SAD. LIMITATIONS: As the study lacks a control group, results lend only preliminary support to the efficacy of the intervention. Furthermore, the mechanism of change remained unclear. CONCLUSION: First results promise a beneficial effect of the program for SAD patients. The treatment proved to be feasible and acceptable. Future research should evaluate the intervention in a randomized-controlled setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Self-help computer-based programs are easily accessible and cost-effective interventions with a great recruitment potential. However, each program is different and results of meta-analyses may not apply to each new program; therefore, evaluations of new programs are warranted. The aim of this study was to assess the marginal efficacy of a computer-based, individually tailored program (the Coach) over and above the use of a comprehensive Internet smoking cessation website. Methods: A two-group randomized controlled trial was conducted. The control group only accessed the website, whereas the intervention group received the Coach in addition. Follow-up was conducted by e-mail after three and six months (self-administrated questionnaires). Of 1120 participants, 579 (51.7%) responded after three months and 436 (38.9%) after six months. The primary outcome was self-reported smoking abstinence over four weeks. Results: Counting dropouts as smokers, there were no statistically significant differences between intervention and control groups in smoking cessation rates after three months (20.2% vs. 17.5%, p¼0.25, odds ratio (OR)¼1.20) and six months (17% vs. 15.5%, p¼0.52, OR¼1.12). Excluding dropouts from the analysis, there were statistically significant differences after three months (42% vs. 31.6%, p¼0.01, OR¼1.57), but not after six months (46.1% vs. 37.8%, p¼0.081, OR¼1.41). The program also significantly increased motivation to quit after three months and self-efficacy after three and six months. Discussion: An individually tailored program delivered via the Internet and by e-mail in addition to a smoking cessation website did not significantly increase smoking cessation rates, but it increased motivation to quit and self-efficacy.