161 resultados para Cholangiopancreatography, Endoscopic Retrograde


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Computer-assisted navigation is increasingly used in functional endoscopic sinus surgery (FESS) to prevent injury to vital structures, necessitating preparative CT and, thus, radiation exposure. The purpose of our study was to investigate currently used radiation doses for CT in computer-assisted navigation in sinus surgery (CAS-CT) and to assess minimal doses required. MATERIALS AND METHODS: A questionnaire inquiring about dose parameters used for CAS-CT was sent to 30 radiologic institutions. The feasibility of low-dose registration was tested with a phantom. The influence of CAS-CT dose on technical accuracy and on the practical performance of 5 ear, nose, and throat (ENT) surgeons was evaluated with cadaver heads. RESULTS: The questionnaire response rate was 63%. Variation between minimal and maximal dose used for CAS-CT was 18-fold. Phantom registration was possible with doses as low as 1.1 mGy. No dose dependence on technical accuracy was found. ENT surgeons were able to identify anatomic landmarks on scans with a dose as low as 3.1 mGy. CONCLUSIONS: The vast dose difference between institutions mirrors different attitudes toward image quality and radiation-protection issues rather than being technically founded, and many patients undergo CAS-CT at higher doses than necessary. The only limit for dose reduction in CT for computer-assisted endoscopic sinus surgery is the ENT surgeon's ability to cope with impaired image quality, whereas there is no technically justified lower dose limit. We recommend, generally, doses used for the typical diagnostic low-dose sinus CT (120 kV/20-50 mAs). When no diagnostic image quality is needed, even a reduction down to a third is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During endoscopic surgery, it is difficult to ascertain the anatomical landmarks once the anatomy is fiddled with or if the operating area is filled with blood. An augmented reality system will enhance the endoscopic view and further enable surgeons to view hidden critical structures or the results of preoperative planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Initial presentation of a white female newborn delivered after normal pregnancy demonstrated a white mass obstructing the left nare. Primary biopsy revealed a focus of fibrotic nasal mucosa that included squamous and respiratory epithelium. After endoscopic resection of the mass, histopathologic examination resulted in the diagnosis of a teratoma. According to our literature review, this is the first case of a teratoma arising from the nasal septum in a white. Worldwide, 3 additional cases have been reported, but none included endoscopic management. This case illustrates our protocol for an endoscopic approach to an obstructive nasal mass in a neonate and our experience in the management of this rare disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Natural orifice transluminal endoscopic surgery (NOTES) is a multidisciplinary surgical technique. If conventional endoscopic instrumentation can be easily mastered, surgeons with laparoscopic experience could head NOTES interventions. MATERIALS AND METHODS: Thirty individuals were tested for endoscopic dexterity. Group 1 included seven gastroenterologists, group 2 included 12 laparoscopically experienced surgeons lacking endoscopic experience, and group 3 included 11 interns who had no hands-on endoscopic or surgical experience. Each individual repeated an easy (T1), medium (T2), and difficult (T3) task ten times with endoscopic equipment on a NOTES skills-box. RESULTS: Group 3 had significantly poorer performances for all three tasks compared to the other groups. No significant differences were seen between groups 1 and 2 for T1 and T2. The initial T3 performance of group 1 was better than that of group 2, but their performance after repetition was not statistically different. Groups 2 and 3 improved significantly with repetition, and group 2 eventually performed as well as group 1. CONCLUSIONS: The data indicate that laparoscopic surgeons quickly learned to handle the endoscopic equipment. This suggests that a lack of endoscopic experience does not handicap laparoscopic surgeons when performing endoscopic tasks. Based on their knowledge of anatomy and the complication management acquired during surgical education, surgeons are well equipped to take the lead in interdisciplinary NOTES collaborations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In this paper we present a landmark-based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope. METHODS: Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set-up. RESULTS: Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set-up (metallic grid) and was 2.25 mm during cadaver studies. CONCLUSIONS: A novel landmark-based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.