82 resultados para Cardiac Events


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Postoperative adynamic bowel atony interferes with recovery following abdominal surgery. Prokinetic pharmacologic drugs are widely used to accelerate postoperative recovery. OBJECTIVES: To evaluate the benefits and harms of systemic acting prokinetic drugs to treat postoperative adynamic ileus in patients undergoing abdominal surgery. SEARCH STRATEGY: Trials were identified by computerised searches of the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and the Cochrane Colorectal Cancer Group specialised register. The reference lists of included trials and review articles were tracked and authors contacted. SELECTION CRITERIA: Randomised controlled parallel-group trials (RCT) comparing the effect of systemically acting prokinetic drugs against placebo or no intervention. DATA COLLECTION AND ANALYSIS: Four reviewers independently extracted the data and assessed trial quality. Trial authors were contacted for additional information if needed. MAIN RESULTS: Thirty-nine RCTs met the inclusion criteria contributing a total of 4615 participants. Most trials enrolled a small number of patients and showed moderate to poor (reporting of) methodological quality, in particular regarding allocation concealment and intention-to-treat analysis. Fifteen systemic acting prokinetic drugs were investigated and ten comparisons could be summarized. Six RCTs support the effect of Alvimopan, a novel peripheral mu receptor antagonist. However, the trials do not meet reporting guidelines and the drug is still in an investigational stage. Erythromycin showed homogenous and consistent absence of effect across all included trials and outcomes. The evidence is insufficient to recommend the use of cholecystokinin-like drugs, cisapride, dopamine-antagonists, propranolol or vasopressin. Effects are either inconsistent across outcomes, or trials are too small and often of poor methodological quality. Cisapride has been withdrawn from the market due to adverse cardiac events in many countries. Intravenous lidocaine and neostigmine might show a potential effect, but more evidence on clinically relevant outcomes is needed. Heterogeneity among included trials was seen in 10 comparisons. No major adverse drug effects were evident. AUTHORS' CONCLUSIONS: Alvimopan may prove to be beneficial but proper judgement needs adherence to reporting standards. Further trials are needed on intravenous lidocaine and neostigmine. The remaining drugs can not be recommended due to lack of evidence or absence of effect.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Vital exhaustion and type D personality previously predicted mortality and cardiac events in patients with chronic heart failure (CHF). Reduced heart rate recovery (HRR) also predicts morbidity and mortality in CHF. We hypothesized that elevated levels of vital exhaustion and type D personality are both associated with decreased HRR. METHODS: Fifty-one patients with CHF (mean age 58+/-12 years, 82% men) and left ventricular ejection fraction (LVEF) cardiac rehabilitation. They completed the 9-item short form of the Maastricht Vital Exhaustion Questionnaire and the 14-item type D questionnaire asking about negative affectivity and social inhibition. HRR was calculated as the difference between heart rate at the end of exercise and 1min after abrupt cessation of exercise (HRR-1). Regression analyses were adjusted for gender, age, LVEF, and maximum exercise capacity. RESULTS: Vital exhaustion explained 8.4% of the variance in continuous HRR-1 (p=0.045). For each point increase on the vital exhaustion score (range 0-18) there was a mean+/-SEM decrease of 0.54+/-0.26bpm in HRR-1. Type D personality showed a trend toward statistical significance for being associated with lower levels of HRR-1 explaining 6.5% of the variance (p<0.08). The likelihood of having HRR-1cardiac outcome in patients with CHF.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS). BACKGROUND: Stenting of small vessels might be associated with higher rates of adverse events. METHODS: "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter 2.75 mm. RESULTS: Of 1,707 patients, 429 patients in the BES group with 576 lesions and 434 patients in the SES group with 557 lesions had only small vessels treated (50.6% of the patient cohort). In patients with small vessels there was no significant difference in overall major adverse cardiac events (MACE) rate (12.1% vs. 11.8%; p = 0.89) or target lesion revascularization (TLR) rate (9.6% vs. 7.4%; p = 0.26) between BES and SES. The MACE and TLR rates in the small-vessel patient population were higher than in the large-vessel population. The TLR rate was 9.6% versus 2.6%, and MACE rate was 12.1% versus 7.1% for small versus large vessels in the BES arm (TLR: hazard ratio [HR] = 3.724, p = 0.0013; MACE: HR = 1.720, p = 0.0412). In the SES arm, TLR was 7.4% versus 5.1%, and MACE was 11.8% versus 10.3% in small versus large vessels (TLR: HR = 1.435, p = 0.2594; MACE: HR = 1.149, p = 0.5546). CONCLUSIONS: Prevalence of small vessel disease is high in an "all-comer" population with higher TLR and MACE rates. The BES and SES seem equivalent in treatment outcomes of small vessels in this "all-comer" patient population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Cardiac surgery is the reference treatment for patients with left main (LM) disease, although percutaneous coronary intervention with drug-eluting stents is emerging as a possible alternative. The objective of this registry was to evaluate the 2-year outcome of elective percutaneous coronary intervention for unprotected LM disease with paclitaxel-eluting stents. METHODS AND RESULTS: A total of 291 patients were prospectively included from 4 centers. Acute myocardial infarction and cardiogenic shock were the only exclusion criteria. Patients were 69+/-11 years old, 29% were diabetic, and 25% had 3-vessel disease. For distal LM lesions (78%), the provisional side-branch T-stenting approach was used in 92% of cases and final kissing balloon inflation in 97%. Angiographic success was obtained in 99.7% of cases. At 2-year follow-up, the total cardiac death rate was 5.4% (1 EuroSCORE point was associated with a 15% [95% confidence interval 2.9% to 28.2%, P=0.013] higher risk of cardiac death), target-lesion revascularization was 8.7%, and incidence of Q-wave or non-Q-wave myocardial infarction was 0.9% and 3.1%, respectively. The combined end point occurred in 15.8% of cases and stroke in 0.7%. The incidence of definite and probable LM stent thrombosis was 0.7%, whereas the incidence of any stent thrombosis was 3.8%, with a higher risk in patients with side-branch stenting in the presence of LM bifurcation lesions (hazard ratio 9.6, 95% confidence interval 1.2 to 77.7, P=0.035). CONCLUSIONS: Unprotected LM stenting with paclitaxel-eluting stents, with a strategy of provisional side-branch T-stenting for distal lesions, provides excellent acute angiographic results and good mid-term clinical outcomes, with a 15.8% rate of major adverse cardiac events at 2-year follow-up.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Newer generation everolimus-eluting stents (EES) improve clinical outcome compared to early generation sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). We investigated whether the advantage in safety and efficacy also holds among the high-risk population of diabetic patients during long-term follow-up. METHODS Between 2002 and 2009, a total of 1963 consecutive diabetic patients treated with the unrestricted use of EES (n=804), SES (n=612) and PES (n=547) were followed throughout three years for the occurrence of cardiac events at two academic institutions. The primary end point was the occurrence of definite stent thrombosis. RESULTS The primary outcome occurred in 1.0% of EES, 3.7% of SES and 3.8% of PES treated patients ([EES vs. SES] adjusted HR=0.58, 95% CI 0.39-0.88; [EES vs. PES] adjusted HR=0.29, 95% CI 0.13-0.67). Similarly, patients treated with EES had a lower risk of target-lesion revascularization (TLR) compared to patients treated with SES and PES ([EES vs. SES], 5.6% vs. 11.5%, adjusted HR=0.68, 95% CI: 0.55-0.83; [EES vs. PES], 5.6% vs. 11.3%, adjusted HR=0.51, 95% CI: 0.33-0.77). There were no differences in other safety end points, such as all-cause mortality, cardiac mortality, myocardial infarction (MI) and MACE. CONCLUSION In diabetic patients, the unrestricted use of EES appears to be associated with improved outcomes, specifically a significant decrease in the need for TLR and ST compared to early generation SES and PES throughout 3-year follow-up.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. Methods and results: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. Conclusions: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES This study sought to assess the clinical safety and effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in patients with in-stent restenosis (ISR) from 2 large trials. BACKGROUND ISR treatment is associated with higher rates of subsequent cardiac events compared with treatment of de novo lesions. Although drug-eluting stents (DES) are an option, second-generation DES are largely untested in the treatment of ISR. METHODS A total of 3,489 patients were pooled from the RAC (RESOLUTE All Comers) trial and the RESOLUTE International (RINT) registry. Two-year clinical endpoints included clinically driven target lesion revascularization (TLR), target lesion failure (TLF), cardiac death (CD), target vessel myocardial infarction (TVMI), combined CD or TVMI (CD/TVMI), and Academic Research Consortium definite and probable stent thrombosis (ST). RESULTS Overall, 281 patients (8.1%) received an R-ZES for ISR. Two-year TLR and TLF rates were significantly higher in ISR patients than in non-ISR patients (TLR: 12.7% vs. 4.3%, p = 0.003; TLF: 17.4% vs. 9.4%, p = 0.007); however, the CD/TVMI rate was not (6.9% vs. 6.1%, p = 0.711). Seven ISR patients had ST. Two-year outcomes by ISR stent type were similar: bare-metal stent (BMS)-ISR TLR was 12.5% and TLF was 17.2%; DES-ISR TLR was 13.0% and TLF was 18.8%. CD/TVMI was 7.3% and 7.2% for BMS-ISR and DES-ISR, respectively. CONCLUSIONS Using R-ZES to treat ISR appears equally safe in BMS-ISR and DES-ISR, with CD/TVMI rates comparable to 2-year outcomes in other clinical trials. Although revascularization rates are still higher in ISR lesions, the R-ZES offers an effective alternative for treatment of BMS-ISR and DES-ISR. (Randomized, Two-Arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; and RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [RINT]; NCT00752128).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE We investigated clinical outcomes after treatment of coronary bifurcation lesions with second generation drug eluting stents (DES). DESIGN Post hoc analysis of a randomised, multicentre, non-inferiority trial. SETTING Multicentre study. PATIENTS All comers study with minimal exclusion criteria. INTERVENTIONS Patients were treated with either zotarolimus or everolimus eluting stents. The patient population was divided according to treatment of bifurcation or non-bifurcation lesions and clinical outcomes were compared between groups. MAIN OUTCOMES MEASURES Clinical outcomes within 2-year follow-up. RESULTS A total of 2265 patients were included in the present analysis. Two-year follow-up data were available in 2223 patients: 1838 patients in the non-bifurcation group and 385 patients in the bifurcation group. At 2-year follow-up the bifurcation and the non-bifurcation lesion groups showed no significant differences in terms of cardiac death (2.3 vs 2.1, p=0.273), target lesion failure (9.7% vs 13.8%, p=0.255), major adverse cardiac events (11.5% vs 15.1%, p=0.305), target lesion revascularisation (4.7% vs 6.0%, p=0.569), and definite or probable stent thrombosis (1.6% vs 1.8%, p=0.419). CONCLUSIONS The use of second generation DES for the treatment of coronary bifurcation lesions was associated with similar long term mortality and clinical outcomes compared with non-bifurcation lesions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes--including death and myocardial infarction (MI)--in clinical studies. OBJECTIVES To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). DESIGN Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. SETTING Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrollment criteria were generally unrestrictive. PATIENTS 5130 patients. MAIN OUTCOME MEASURES 2-year clinical outcomes and 13-month angiographic outcomes. RESULTS 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES. CONCLUSIONS Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes--including repeat revascularisation--to non-overlapping DES.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to provide the spectrum and prevalence of mutations in the 12 Brugada syndrome (BrS)-susceptibility genes discovered to date in a single large cohort of unrelated BrS patients. BACKGROUND BrS is a potentially lethal heritable arrhythmia syndrome diagnosed electrocardiographically by coved-type ST-segment elevation in the right precordial leads (V1 to V3; type 1 Brugada electrocardiographic [ECG] pattern) and the presence of a personal/family history of cardiac events. METHODS Using polymerase chain reaction, denaturing high-performance liquid chromatography, and DNA sequencing, comprehensive mutational analysis of BrS1- through BrS12-susceptibility genes was performed in 129 unrelated patients with possible/probable BrS (46 with clinically diagnosed BrS [ECG pattern plus personal/family history of a cardiac event] and 83 with a type 1 BrS ECG pattern only). RESULTS Overall, 27 patients (21%) had a putative pathogenic mutation, absent in 1,400 Caucasian reference alleles, including 21 patients with an SCN5A mutation, 2 with a CACNB2B mutation, and 1 each with a KCNJ8 mutation, a KCND3 mutation, an SCN1Bb mutation, and an HCN4 mutation. The overall mutation yield was 23% in the type 1 BrS ECG pattern-only patients versus 17% in the clinically diagnosed BrS patients and was significantly greater among young men<20 years of age with clinically diagnosed BrS and among patients who had a prolonged PQ interval. CONCLUSIONS We identified putative pathogenic mutations in ∼20% of our BrS cohort, with BrS genes 2 through 12 accounting for <5%. Importantly, the yield was similar between patients with only a type 1 BrS ECG pattern and those with clinically established BrS. The yield approaches 40% for SCN5A-mediated BrS (BrS1) when the PQ interval exceeds 200 ms. Calcium channel-mediated BrS is extremely unlikely in the absence of a short QT interval.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The long QT syndrome (LQTS) is a genetic disorder characterized by prolongation of the QT interval in the electrocardiogram (ECG) and a propensity to "torsades de pointes" ventricular tachycardia frequently leading to syncope, cardiac arrest, or sudden death usually in young otherwise healthy individuals. LQTS caused by mutations of predominantly potassium and sodium ion channel genes or channel-interacting proteins leading to positive overcharge of myocardial cell with consequent heterogeneous prolongation of repolarization in various layers and regions of myocardium. These conditions facilitate the early after-depolarization and reentry phenomena underlying development of polymorphic ventricular tachycardia observed in patients with LQTS. Obtaining detailed patient history regarding cardiac events in the patient and his/her family members combined with careful interpretation of standard 12-lead ECG (with precise measurement of QT interval in all available ECGs and evaluation of T-wave morphology) usually is sufficient to diagnose the syndrome. The LQTS show great genetic heterogeneity and has been identified more than 500 mutations distributed in 10 genes: KCNQ1, HERG, SCN5A, KCNE1, KCNE2, ANKB, KCNJ2, CACNA1A, CAV3 and SCN4B. Despite advances in the field, 25-30% of patients remain undiagnosed genetic. Genetic testing plays an important role and is particularly useful in cases with nondiagnostic or borderline ECG findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To expand the limited information on the prognostic impact of quantitatively obtained collateral function in patients with coronary artery disease (CAD) and to estimate causality of such a relation. DESIGN Prospective cohort study with long-term observation of clinical outcome. SETTING University Hospital. PATIENTS One thousand one hundred and eighty-one patients with chronic stable CAD undergoing 1771 quantitative, coronary pressure-derived collateral flow index measurements, as obtained during a 1-min coronary balloon occlusion (CFI is the ratio between mean distal coronary occlusive pressure and mean aortic pressure both subtracted by central venous pressure). Subgroup of 152 patients included in randomised trials on the longitudinal effect of different arteriogenic protocols on CFI. INTERVENTIONS Collection of long-term follow-up information on clinical outcome. MAIN OUTCOME MEASURES All-cause mortality and major adverse cardiac events. RESULTS Cumulative 15-year survival rate was 48% in patients with CFI<0.25 and 65% in the group with CFI≥0.25 (p=0.0057). Cumulative 10-year survival rate was 75% in patients without arteriogenic therapy and 88% (p=0.0482) in the group with arteriogenic therapy and showing a significant increase in CFI at follow-up. By proportional hazard analysis, the following variables predicted increased all-cause mortality: age, low CFI, left ventricular end-diastolic pressure and number of vessels with CAD. CONCLUSIONS A well-functioning coronary collateral circulation independently predicts lowered mortality in patients with chronic CAD. This relation appears to be causal, because augmented collateral function by arteriogenic therapy is associated with prolonged survival.