137 resultados para Cannula, Ventricular assist device, Rotary blood pump, Heart failure
Resumo:
Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision.
Resumo:
Seromas occurring around a vascular graft are a rare complication. We report a life-threatening plasma leakage that occurred through the polytetrafluoroethylene vascular prosthesis of an Impella right ventricular assist device (Impella RD [Impella Cardiosystems GmbH, Aachen, Germany]) implanted in a 62-year-old patient with acute right ventricular failure after cardiac transplantation. The leakage became progressively massive. Weaning the patient from the right ventricular assist device was not possible. The prosthesis was thus wrapped within a pericardial patch to contain the leakage. Three days later the patient could be successfully weaned and the pump was removed. The clinical evolution was favorable.
Resumo:
Background Whole-body water immersion leads to a significant shift of blood from the periphery into the intra-thoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically in-duced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. The aim of this study is to assess the hemodynamic response to water immer-sion, gymnastics and swimming in patients with heart failure (CHF). Methods We examined 10 patients with compensated CHF (62.9 +/- 6.3 years, EF 31.5 +/- 4.1%, peak VO2 19.4 +/- 2.8 ml/kg/min.), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 +/- 5.6 years, EF 63.9 +/- 5.5%, peak VO2 28.0 +/- 6.3 ml/kg/min.) and 10 healthy subjects (32.8 +/- 7.2 years, peak VO2 45.6 +/- 6.0 ml/kg/min.). Hemodynamic response to thermo-neutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Results Water immersion up to the chest increased cardiac index by 19% in healthy subjects, by 21% in CAD patients and 16% in CHF patients. While some CHF patients showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, 77% in CAD patients and 53% in CHF patients). Oxygen uptake during swim-ming was 9.7 +/- 3.3 ml/kg/min. in CHF patients, 12.4 +/- 3.5 ml/kg/min. in CAD patients and 13.9 +/- 4.0 ml/kg/min. in healthy subjects. Conclusions Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak VO2 of at least 15 ml/kg/min. during a symptom-limited exercise stress test tolerate water immersion and swimming in thermo-neutral water well. Although cardiac in-dex and oxygen uptake are lower compared with CAD patients with preserved left ventricular function and healthy controls, these patients are able to increase cardiac index adequately during water immersion and swimming.
Resumo:
BACKGROUND: Increased activity of single ventricular L-type Ca(2+)-channels (L-VDCC) is a hallmark in human heart failure. Recent findings suggest differential modulation by several auxiliary beta-subunits as a possible explanation. METHODS AND RESULTS: By molecular and functional analyses of human and murine ventricles, we find that enhanced L-VDCC activity is accompanied by altered expression pattern of auxiliary L-VDCC beta-subunit gene products. In HEK293-cells we show differential modulation of single L-VDCC activity by coexpression of several human cardiac beta-subunits: Unlike beta(1) or beta(3) isoforms, beta(2a) and beta(2b) induce a high-activity channel behavior typical of failing myocytes. In accordance, beta(2)-subunit mRNA and protein are up-regulated in failing human myocardium. In a model of heart failure we find that mice overexpressing the human cardiac Ca(V)1.2 also reveal increased single-channel activity and sarcolemmal beta(2) expression when entering into the maladaptive stage of heart failure. Interestingly, these animals, when still young and non-failing ("Adaptive Phase"), reveal the opposite phenotype, viz: reduced single-channel activity accompanied by lowered beta(2) expression. Additional evidence for the cause-effect relationship between beta(2)-subunit expression and single L-VDCC activity is provided by newly engineered, double-transgenic mice bearing both constitutive Ca(V)1.2 and inducible beta(2) cardiac overexpression. Here in non-failing hearts induction of beta(2)-subunit overexpression mimicked the increase of single L-VDCC activity observed in murine and human chronic heart failure. CONCLUSIONS: Our study presents evidence of the pathobiochemical relevance of beta(2)-subunits for the electrophysiological phenotype of cardiac L-VDCC and thus provides an explanation for the single L-VDCC gating observed in human and murine heart failure.
Resumo:
Left ventricular assist devices were developed to support the function of a failing left ventricle. Owing to recent technological improvements, ventricular assist devices can be placed by percutaneous implantation techniques, which offer the advantage of fast implantation in the setting of acute left ventricular failure. This article reviews the growing evidence supporting the clinical use of left ventricular assist devices. Specifically, we discuss the use of left ventricular assist devices in patients with cardiogenic shock, in patients with acute ST-elevation myocardial infarction without shock, and during high-risk percutaneous coronary interventions.
Resumo:
The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.
Resumo:
BACKGROUND Prognostic classification of congestive heart failure (CHF) is difficult and only possible with the help of additional diagnostic tools. B-type natriuretic peptide (BNP) has been used as a diagnostic and prognostic marker for patients (pts) with CHF. In this study, the clinical value of BNP for stratification and treatment of pts with CHF was evaluated. PATIENTS AND METHODS 33 out-pts with CHF (age 57 +/- 12 years) were included. Left-ventricular (LV) ejection fraction (EF) was 27 +/- 8% (mean +/- SD) and NYHA-class 2.4 +/- 0.7. Following parameters were measured: BNP and sodium from blood samples, exercise performance from 6-minute walking test (6MWT, meters) (n = 18), LV end-diastolic diameter (LVEDD) and LV mass (LVM) from 2D-echocardiography (n = 33), as well as LV end-diastolic pressure (LVEDP, n = 23) and systemic vascular resistance (SVR, n = 20) from heart-catheterisation. Ten pts were hospitalised in the preceding 6 months because of worsening CHF or for optimisation of medical therapy. BNP was measured at the beginning and end of the hospital-stay. Follow-up was for 1 year. RESULTS Pts with a high NYHA-class had a higher BNP (pg/ml) than those with a low NYHA- class: NYHA I 51 +/- 20, II 281 +/- 223, III 562+/-346 and IV 1061 +/- 126 pg/ml (p = 0.002). BNP correlated with LVEDP (r = 0.50, p <0.02), SVR (r =0.49, p <0.03) and inversely with 6MWT (r =-0.60, p <0.009), LVEF (r = -0.49, p <0.004) and sodium (r = -0.36, p = 0.04). In the hospitalised pts, mean BNP (pg/ml) was 881 +/- 695 at admission,and 532 +/- 435 at discharge (n.s.). Decrease in BNPduring hospitalisation paralleled weight-loss and was significantly greater in patients with >1000 pg/ml BNP at admission (n = 5) as compared to the 5 patients with BNP <1000 (p <0.03). Patients with an adverse event during 1-year follow-up had significantly higher BNP both at steady-state (603 +/-359 pg/ml) and at time of decompensation than patients with a favourable outcome (227 +/- 218 pg/ml,p <0.001). CONCLUSIONS BNP correlates well with the clinical severity of CHF (NYHA-class) and is directly related to filling pressure (LVEDP), LV function(LVEF) and exercise performance (6 MWT). Furthermore, BNP has prognostic impact with regard to adverse clinical events.
Resumo:
Aldosterone plays an important role in the pathophysiology of heart failure. Aldosterone receptor blockade has been shown to reduce morbidity and mortality in human patients with advanced congestive left ventricular heart failure. This study was designed to assess the efficacy and tolerance of long-term low-dose spironolactone when added to conventional heart failure treatment in dogs with advanced heart failure. Eighteen client-owned dogs with advanced congestive heart failure due to either degenerative valve disease (n=11) or dilated cardiomyopathy (n=7) were included in this prospective, placebo-controlled, double-blinded, randomized clinical study. After initial stabilization including furosemide, angiotensin-converting enzyme inhibitors, pimobendan and digoxin, spironolactone at a median dose of 0.52 mg/kg (range 0.49-0.8 mg/kg) once daily (n=9) or placebo (n=9) was added to the treatment, and the dogs were reassessed 3 and 6 months later. Clinical scoring, echocardiography, electrocardiogram, systolic blood pressure measurement, thoracic radiography, sodium, potassium, urea, creatinine, alanine aminotransferase, aldosterone and aminoterminal atrial natriuretic propeptide were assessed at baseline, 3 and 6 months. Survival times were not significantly different between the two treatment groups. Spironolactone was well tolerated when combined with conventional heart failure treatment.
Resumo:
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded on 10 December 2009 with the initiative of Roland Hetzer (Deutsches Herzzentrum Berlin, Berlin, Germany) and Jan Gummert (Herz- und Diabeteszentrum Nordrhein-Westfalen, Bad Oeynhausen, Germany) with 15 other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry of device implantation data and long-term follow-up of patients with mechanical circulatory support. Hence, EUROMACS affiliated itself with Dendrite Clinical Systems Ltd to offer its members a software tool that allows input and analysis of patient clinical data on a daily basis. EUROMACS facilitates further scientific studies by offering research groups access to any available data wherein patients and centres are anonymized. Furthermore, EUROMACS aims to stimulate cooperation with clinical and research institutions and with peer associations involved to further its aims. EUROMACS is the only European-based Registry for Patients with Mechanical Circulatory Support with rapid increase in institutional and individual membership. Because of the expeditious data input, the European Association for Cardiothoracic Surgeons saw the need to optimize the data availability and the significance of the registry to improve care of patients with mechanical circulatory support and its potential contribution to scientific intents; hence, the beginning of their alliance in 2012. This first annual report is designed to provide an overview of EUROMACS' structure, its activities, a first data collection and an insight to its scientific contributions.
Resumo:
Atrial fibrillation (AF) and heart failure (HF) are common and interrelated conditions, each promoting the other, and both associated with increased mortality. HF leads to structural and electrical atrial remodeling, thus creating the basis for the development and perpetuation of AF; and AF may lead to hemodynamic deterioration and the development of tachycardia-mediated cardiomyopathy. Stroke prevention by antithrombotic therapy is crucial in patients with AF and HF. Of the 2 principal therapeutic strategies to treat AF, rate control and rhythm control, neither has been shown to be superior to the other in terms of survival, despite better survival in patients with sinus rhythm compared with those in AF. Antiarrhythmic drug toxicity and poor efficacy are concerns. Catheter ablation of AF can establish sinus rhythm without the risks of antiarrhythmic drug therapy, but has important procedural risks, and data from randomized trials showing a survival benefit of this treatment strategy are still lacking. In intractable cases, ablation of the atrioventricular junction and placement of a permanent pacemaker is a treatment alternative; and biventricular pacing may prevent or reduce the negative consequences of chronic right ventricular pacing.
Resumo:
Exertional oscillatory ventilation (EOV) is an ominous prognostic sign in chronic heart failure (CHF), but little is known about the success of specific therapeutic interventions. Our aim was to study the impact of an exercise training on exercise capacity and cardiopulmonary adaptation in stable CHF patients with left ventricular systolic dysfunction and EOV. 96 stable CHF patients with EOV were included in a retrospective analysis (52 training versus 44 controls). EOV was defined as follows: 1) three or more oscillatory fluctuations in minute ventilation (V'(E)) during exercise; 2) regular oscillations; and 3) minimal average ventilation amplitude ≥5 L. EOV disappeared in 37 (71.2%) out of 52 patients after training, but only in one (2.3%) out of 44 without training (p<0.001). The decrease of EOV amplitude correlated with changes in end-tidal carbon dioxide tension (r= -0.60, p<0.001) at the respiratory compensation point and V'(E)/carbon dioxide production (V'(CO(2))) slope (r=0.50, p<0.001). Training significantly improved resting values of respiratory frequency (f(R)), V'(E), tidal volume (V(T)) and V'(E)/V'(CO(2)) ratio. During exercise, V'(E) and V(T) reached significantly higher values at the peak, while f(R) and V'(E)/V'(CO(2)) ratio were significantly lower at submaximal exercise. No change was noted in the control group. Exercise training leads to a significant decrease of EOV and improves ventilatory efficiency in patients with stable CHF.
Resumo:
OBJECTIVE(S): Even though the mechanism is not clearly understood, direct intramyocardial cell transplantation has demonstrated potential to treat patients with severe heart failure. We previously reported on the bioengineering of myoblast-based constructs. We investigate here the functional outcome of infarcted hearts treated by implantation of myoblast-seeded scaffolds. METHODS: Adult Lewis rats with echocardiography-confirmed postinfarction reduced ejection fraction (48.3% +/- 1.1%) were randomized to (1) implantation of myoblast-seeded polyurethane patches at the site of infarction (PU-MyoB, n = 11), (2) implantation of nonseeded polyurethane patches (PU, n = 11), (3) sham operation (Sham, n = 12), and (4) direct intramyocardial myoblast injection (MyoB, n = 11). Four weeks later, the functional assessment by echocardiography was repeated, and we additionally performed left ventricular catheterization plus histologic studies. RESULTS: The ejection fraction significantly decreased in the PU (39.1% +/- 2.3%; P = .02) and Sham (39.9% +/- 3.5%; P = .04) groups, whereas it remained stable in the PU-MyoB (48.4% +/- 3.1%) and MyoB (47.9% +/- 3.0%) groups during the observation time. Similarly, left ventricular contractility was significantly higher in groups PU-MyoB (4960 +/- 266 mm Hg/s) and MyoB (4748 +/- 304 mm Hg/s) than in groups PU (3909 +/- 248 mm Hg/s, P = .01) and Sham (4028 +/- 199 mm Hg/s, P = .01). Immunohistology identified a high density of myoblasts within the seeded scaffolds without any migration toward the host cardiac tissue and no evidence of cardiac cell differentiation. CONCLUSIONS: Myoblast-seeded polyurethane scaffolds prevent post-myocardial infarction progression toward heart failure as efficiently as direct intramyocardial injection. The immunohistologic analysis suggests that an indirect mechanism, potentially a paracrine effect, may be assumed.
Resumo:
BACKGROUND: Elevated pulmonary vascular resistance (PVR) is relevant to prognosis of congestive heart failure and heart transplantation. Proof of reversibility by pharmacologic testing in potential transplantation candidates is important because it indicates a reduced probability of right ventricular failure or death in the early post-transplant period. This study aimed to clarify the possible extent of acute reversibility of elevated PVR in a large, consecutive cohort of heart transplant candidates. METHODS: This study included 208 consecutive patients (age 52 +/- 10 years, 89% men and 11% women, ejection fraction 21 +/- 9%, Vo2max 12.6 +/- 4.2 ml/kg/min) being evaluated for heart transplantation in 7 transplant centers in Germany and Switzerland. Testing was performed with increasing intravenous doses of prostaglandin E1 (PGE1; average maximum dose 173 +/- 115 ng/kg/min for at least 10 minutes) in 92 patients exhibiting a baseline PVR of > 2.5 Wood units (WU) and/or a transpulmonary gradient (TPG) of > 12 mm Hg. RESULTS: PGE1 testing lowered PVR from 4.1 +/- 2.0 to 2.1 +/- 1.1 WU (p < 0.01), increased cardiac output from 3.8 +/- 1.0 to 5.0 +/- 1.5 liters/min (p < 0.01), and decreased TPG from 14 +/- 4 to 10 +/- 3 mm Hg (p < 0.01), mean pulmonary artery pressure (PAM) from 39 +/- 9 to 29 +/- 9 mm Hg (p < 0.01) and mean pulmonary capillary wedge pressure (PCWP) from 24 +/- 7 to 19 +/- 9 mm Hg (p < 0.01). Mean aortic pressure (MAP) decreased to 85% and systemic vascular resistance (SVR) to 65% of baseline values (p < 0.01). Symptomatic systemic hypotension was not observed. For the whole population the percentage of patients with PVR > 2.5 WU was reduced from 44.2% to 10.5% with PGE1. PVR decreased in each patient; only 2 patients (1%) remained ineligible for listing because of a final PVR of > 4.0 WU. TPG, ejection fraction and male gender were independent predictors of reversibility of PVR. CONCLUSIONS: Elevated PVR in heart transplant candidates is highly reversible and can be normalized during acute pharmacologic testing with PGE1.