95 resultados para CLINICAL ROUTINE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: Lymph node status is an important prognostic factor in patients with squamous cell carcinoma (SCC) of the vulva. Complete inguinofemoral lymph node dissection (ILND) is accompanied by a high morbidity. Sentinel lymph node biopsy (SLNB) was established for less invasive lymph node (LN) staging. The aim of this study was to evaluate safety of SLNB in terms of accuracy and outcome in a clinical routine setting. METHODS: We retrospectively reviewed the data of patients who underwent SLNB and/or ILND for vulvar SCC in the years 1990-2007. Clinical follow-up was evaluated for histological nodal-negative patients with tumor stage T1 or T2. The false negative rate of SLNB was determined in patients who underwent both SLNB and ILND. RESULTS: Preoperative sentinel lymph node (SLN) visualization by scintigraphy was successful in 95% of all patients. SLNB was false negative in 1/45 inguinae (2.2%). All SLN were detected intraoperatively. During the follow-up period (median 24 months for SLNB and 111 months for ILND), no groin recurrences in initially nodal negative patients occurred (n=34, 59 inguinae). Transient lymph edema occurred in 7/18 patients after ILND (39%) and 2/16 patients (13%) after SLNB. No persistent edemas were found after SLNB and ILND. CONCLUSION: According to our experience SLNB is feasible and accurately predicts LN status of vulvar SCC under clinical routine conditions. SLNB in vulvar cancer seems to be a safe alternative to ILND in order to reduce morbidity of surgical treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diagnosis of drug allergy involves first the recognition of sometimes unusual symptoms as drug allergy and, second, the identification of the eliciting drug. This is an often difficult task, as the clinical picture and underlying pathomechanisms are heterogeneous. In clinical routine, physicians frequently have to rely upon a suggestive history and eventual provocation tests, both having their specific limitations. For this reason both in vivo (skin tests) and in vitro tests are investigated intensively as tools to identify the disease-eliciting drug. One of the tests evaluated in drug allergy is the basophil activation test (BAT). Basophils with their high-affinity IgE receptors are easily accessible and therefore can be used as indicator cells for IgE-mediated reactions. Upon allergen challenge and cross-linking of membrane-bound IgE antibodies (via Fc-epsilon-RI) basophils up-regulate certain activation markers on their surface such as CD63 and CD203c, as well as intracellular markers (eg, phosphorylated p38MAPK). In BAT, these alterations can be detected rapidly on a single-cell basis by multicolor flow cytometry using specific monoclonal antibodies. Combining this technique with in vitro passive sensitization of donor basophils with patients' serum, one can prove the IgE dependence of a drug reaction. This article summarizes the authors' current experience with the BAT in the diagnostic management of immediate-type drug allergy mediated by drug-specific IgE antibodies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Prosthetic and osteosynthetic implants from metal alloys will be indispensable in orthopedic surgery, as long as tissue engineering and biodegradable bone substitutes do not lead to products that will be applied in clinical routine for the repair of bone, cartilage, and joint defects. Therefore, the elucidation of the interactions between the periprosthetic tissues and the implant remains of clinical relevance and several factors are known to affect the longevity of implants. Within this study, the effects of metal particles and surface topography on the recruitment of osteoclasts was investigated in vitro in a coculture of osteoblasts and bone marrow cells. The cells were grown in the presence of particles of different sizes and chemical composition or on metal discs with polished or sandblasted surfaces, respectively. At the end of the culture, newly formed osteoclasts were counted. Osteoclastogenesis was reduced when particles were added directly to the coculture. The effect depended on the size of the particles, small particles exerting stronger effects than larger ones. The chemical composition of the particles, however, did not affect the development of osteoclasts. In cocultures grown on sandblasted surfaces, osteoclasts developed at higher rates than they did in cultures on polished surfaces. The data demonstrate that wear particles and implant surfaces affect osteoclastogenesis and thus may be involved in the induction of local bone resorption and the formation of osteolytic lesions, leading eventually to the loosening of orthopedic implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In addition to self reports and questionnaires, biomarkers are of relevance in the diagnosis of and therapy for alcohol use disorders. Traditional biomarkers such as gamma-glutamyl transpeptidase or mean corpuscular volume are indirect biomarkers and are subject to the influence of age, gender and non-alcohol related diseases, among others. Direct metabolites of ethanol such as Ethyl glucuronide (EtG), ethyl sulphate (EtS) and phosphatidylethanol (PEth) are direct metabolites of ethanol, that are positive after intake of ethyl alcohol. They represent useful diagnostic tools for identifying alcohol use even more accurately than traditional biomarkers. Each of these drinking indicators remains positive in serum and urine for a characteristic time spectrum after the cessation of ethanol intake - EtG and EtS in urine up to 7 days, EtG in hair for months after ethanol has left the body. Applications include clinical routine use, emergency room settings, proof of abstinence in alcohol rehabilitation programmes, driving under influence offenders, workplace testing, assessment of alcohol intake in the context of liver transplantation and foetal alcohol syndrome. Due to their properties, they open up new perspectives for prevention, interdisciplinary cooperation, diagnosis of and therapy for alcohol-related problems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The immune system is able to specifically target antigen-expressing cancer cells. The promise of immunotherapy was to eliminate cancer cells without harming normal tissue and, therefore, with no or very few side effects. Immunotherapy approaches have, for several decades, been tested against several tumours, most often against malignant melanoma. However, although detectable immune responses have regularly been induced, the clinical outcome has often been disappointing. The development of molecular methods and an improved understanding of tumour immunosurveillance led to novel immunotherapy approaches in the last few years. First randomised phase III trials proved that immunotherapy can prolong survival of patients with metastatic melanoma or prostate cancer. The development in the field is very rapid and various molecules (mainly monoclonal antibodies) that activate the immune system are currently being tested in clinical trials and will possibly change our treatment of cancer. The ultimate goal of any cancer therapy and also immunotherapy is to cure cancer. However, this depends on the elimination of the disease originating cancer stem cells. Unfortunately, cancer stem cells seem resistant to most available treatment options. Recent developments in immunotherapy may allow targeting these cancer stem cells specifically in the future. In this review, we summarise the current state of immunotherapy in clinical routine and the expected developments in the near future.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alcohol and tobacco related disorders are the two leading and most expensive causes of illness in central Europe. In addition to self reports and questionnaires, biomarkers are of relevance in diagnosis and therapy of alcohol use disorders.Traditional biomarkers such as gamma glutamyl transpeptidase or mean corpuscualr volume are indirect biomarkers and are subject to influence of age, gender and non alcohol related diseases, among others.Direct ethanol metabolites such as ethyl glucuronide (EtG), ethyl sulphate (EtS) and phosphatidylethanol (PEth) are direct metabolites of ethanol, that are positive after intake of ethyl alcohol. They represent useful diagnostic tools for identifying alcohol use even more accurately than traditional biomarkers. Each of these drinking indicators remains positive in serum and urine for a characteristic time spectrum after the cessation of ethanol intake-EtG and EtS in urine up to 7 days, EtG in hair for months after ethanol has left the body. Applications include clinical routine use, emergency room settings, proof of abstinence in alcohol rehabilitation programs, driving under influence offenders, workplace testing, assessment of alcohol intake in the context of liver transplantation and fetal alcohol syndrome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bonebridge™ (BB) implantation relies on optimal anchoring of the bone-conduction implant in the temporal bone. Preoperative position planning has to account for the available bone thickness minimizing unwanted interference with underlying anatomical structures. This study describes the first clinical experience with a planning method based on topographic bone thickness maps (TBTM) for presigmoid BB implantations. The temporal bone was segmented enabling three-dimensional surface generation. Distances between the external and internal surface were color encoded and mapped to a TBTM. Suitable implant positions were planned with reference to the TBTM. Surgery was performed according to the standard procedure (n = 7). Computation of the TBTM and consecutive implant position planning took 70 min on average for a trained technician. Surgical time for implantations under passive TBTM image guidance was 60 min, on average. The sigmoid sinus (n = 5) and dura mater (n = 1) were exposed, as predicted with the TBTM. Feasibility of the TBTM method was shown for standard presigmoid BB implantations. The projection of three-dimensional bone thickness information into a single topographic map provides the surgeon with an intuitive display of the anatomical situation prior to implantation. Nevertheless, TBTM generation time has to be significantly reduced to simplify integration in clinical routine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reconstruction of shape and intensity from 2D x-ray images has drawn more and more attentions. Previously introduced work suffers from the long computing time due to its iterative optimization characteristics and the requirement of generating digitally reconstructed radiographs within each iteration. In this paper, we propose a novel method which uses a patient-specific 3D surface model reconstructed from 2D x-ray images as a surrogate to get a patient-specific volumetric intensity reconstruction via partial least squares regression. No DRR generation is needed. The method was validated on 20 cadaveric proximal femurs by performing a leave-one-out study. Qualitative and quantitative results demonstrated the efficacy of the present method. Compared to the existing work, the present method has the advantage of much shorter computing time and can be applied to both DXA images as well as conventional x-ray images, which may hold the potentials to be applied to clinical routine task such as total hip arthroplasty (THA).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Patients presenting to the emergency department (ED) currently face inacceptable delays in initial treatment, and long, costly hospital stays due to suboptimal initial triage and site-of-care decisions. Accurate ED triage should focus not only on initial treatment priority, but also on prediction of medical risk and nursing needs to improve site-of-care decisions and to simplify early discharge management. Different triage scores have been proposed, such as the Manchester triage system (MTS). Yet, these scores focus only on treatment priority, have suboptimal performance and lack validation in the Swiss health care system. Because the MTS will be introduced into clinical routine at the Kantonsspital Aarau, we propose a large prospective cohort study to optimize initial patient triage. Specifically, the aim of this trial is to derive a three-part triage algorithm to better predict (a) treatment priority; (b) medical risk and thus need for in-hospital treatment; (c) post-acute care needs of patients at the most proximal time point of ED admission. Methods/design: Prospective, observational, multicenter, multi-national cohort study. We will include all consecutive medical patients seeking ED care into this observational registry. There will be no exclusions except for non-adult and non-medical patients. Vital signs will be recorded and left over blood samples will be stored for later batch analysis of blood markers. Upon ED admission, the post-acute care discharge score (PACD) will be recorded. Attending ED physicians will adjudicate triage priority based on all available results at the time of ED discharge to the medical ward. Patients will be reassessed daily during the hospital course for medical stability and readiness for discharge from the nurses and if involved social workers perspective. To assess outcomes, data from electronic medical records will be used and all patients will be contacted 30 days after hospital admission to assess vital and functional status, re-hospitalization, satisfaction with care and quality of life measures. We aim to include between 5000 and 7000 patients over one year of recruitment to derive the three-part triage algorithm. The respective main endpoints were defined as (a) initial triage priority (high vs. low priority) adjudicated by the attending ED physician at ED discharge, (b) adverse 30 day outcome (death or intensive care unit admission) within 30 days following ED admission to assess patients risk and thus need for in-hospital treatment and (c) post acute care needs after hospital discharge, defined as transfer of patients to a post-acute care institution, for early recognition and planning of post-acute care needs. Other outcomes are time to first physician contact, time to initiation of adequate medical therapy, time to social worker involvement, length of hospital stay, reasons fordischarge delays, patient’s satisfaction with care, overall hospital costs and patients care needs after returning home. Discussion: Using a reliable initial triage system for estimating initial treatment priority, need for in-hospital treatment and post-acute care needs is an innovative and persuasive approach for a more targeted and efficient management of medical patients in the ED. The proposed interdisciplinary , multi-national project has unprecedented potential to improve initial triage decisions and optimize resource allocation to the sickest patients from admission to discharge. The algorithms derived in this study will be compared in a later randomized controlled trial against a usual care control group in terms of resource use, length of hospital stay, overall costs and patient’s outcomes in terms of mortality, re-hospitalization, quality of life and satisfaction with care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE The ACCESS treatment model offers assertive community treatment embedded in an integrated care program to patients with psychoses. Compared to standard care and within a controlled study, it proved to be more effective in terms of service disengagement and illness outcomes in patients with schizophrenia spectrum disorders over 12 months. ACCESS was implemented into clinical routine and its effectiveness assessed over 24 months in severe schizophrenia spectrum disorders and bipolar I disorder with psychotic features (DSM-IV) in a cohort study. METHOD All 115 patients treated in ACCESS (from May 2007 to October 2009) were included in the ACCESS II study. The primary outcome was rate of service disengagement. Secondary outcomes were change of psychopathology, severity of illness, psychosocial functioning, quality of life, satisfaction with care, medication nonadherence, length of hospital stay, and rates of involuntary hospitalization. RESULTS Only 4 patients (3.4%) disengaged with the service. Another 11 (9.6%) left because they moved outside the catchment area. Patients received a mean of 1.6 outpatient contacts per week. Involuntary admissions decreased from 34.8% in the 2 previous years to 7.8% during ACCESS (P < .001). Mixed models repeated-measures analyses revealed significant improvements among all patients in psychopathology (effect size d = 0.64, P < .001), illness severity (d = 0.84, P = .03), functioning level (d = 0.65, P < .001), quality of life (d = 0.50, P < .001), and client satisfaction (d = 0.11, P < .001). At 24 months, 78.3% were fully adherent to medication, compared to 25.2% at baseline (P = .002). CONCLUSIONS ACCESS was successfully implemented in clinical routine and maintained excellent rates of service engagement and other outcomes in patients with schizophrenia spectrum disorders or bipolar I disorder with psychotic features over 24 months. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT01888627.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Teamwork and the interprofessional collaboration of all health professions are a guarantee of patient safety and highly qualified treatment in patient care. In the daily clinical routine, physicians and nurses must work together, but the education of the different health professions occurs separately in various places, mostly without interrelated contact. Such training abets mutual misunderstanding and cements professional protectionism, which is why interprofessional education can play an important role in dismantling such barriers to future cooperation. In this article, a pilot project in interprofessional education involving both medical and nursing students is presented, and the concept and the course of training are described in detail. The report illustrates how nursing topics and anatomy lectures can be combined for interprofessional learning in an early phase of training. Evaluation of the course showed that the students were highly satisfied with the collaborative training and believed interprofessional education (IPE) to be an important experience for their future profession and understanding of other health professionals. The results show that the IPE teaching concept, which combines anatomy and nursing topics, provides an optimal setting for learning together and helps nurses and doctors in training to gain knowledge about other health professionals’ roles, thus evolving mutual understanding.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.