39 resultados para Artefact rejection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Risk factors and outcomes of bronchial stricture after lung transplantation are not well defined. An association between acute rejection and development of stricture has been suggested in small case series. We evaluated this relationship using a large national registry. METHODS: All lung transplantations between April 1994 and December 2008 per the United Network for Organ Sharing (UNOS) database were analyzed. Generalized linear models were used to determine the association between early rejection and development of stricture after adjusting for potential confounders. The association of stricture with postoperative lung function and overall survival was also evaluated. RESULTS: Nine thousand three hundred thirty-five patients were included for analysis. The incidence of stricture was 11.5% (1,077/9,335), with no significant change in incidence during the study period (P=0.13). Early rejection was associated with a significantly greater incidence of stricture (adjusted odds ratio [AOR], 1.40; 95% confidence interval [CI], 1.22-1.61; p<0.0001). Male sex, restrictive lung disease, and pretransplantation requirement for hospitalization were also associated with stricture. Those who experienced stricture had a lower postoperative peak percent predicted forced expiratory volume at 1 second (FEV1) (median 74% versus 86% for bilateral transplants only; p<0.0001), shorter unadjusted survival (median 6.09 versus 6.82 years; p<0.001) and increased risk of death after adjusting for potential confounders (adjusted hazard ratio 1.13; 95% CI, 1.03-1.23; p=0.007). CONCLUSIONS: Early rejection is associated with an increased incidence of stricture. Recipients with stricture demonstrate worse postoperative lung function and survival. Prospective studies may be warranted to further assess causality and the potential for coordinated rejection and stricture surveillance strategies to improve postoperative outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Cytomegalovirus (CMV) replication has been associated with more risk for solid organ graft rejection. We wondered whether this association still holds when patients at risk receive prophylactic treatment for CMV. METHODS We correlated CMV infection, biopsy-proven graft rejection, and graft loss in 1,414 patients receiving heart (n=97), kidney (n=917), liver (n=237), or lung (n=163) allografts reported to the Swiss Transplant Cohort Study. RESULTS Recipients of all organs were at an increased risk for biopsy-proven graft rejection within 4 weeks after detection of CMV replication (hazard ratio [HR] after heart transplantation, 2.60; 95% confidence interval [CI], 1.34-4.94, P<0.001; HR after kidney transplantation, 1.58; 95% CI, 1.16-2.16, P=0.02; HR after liver transplantation, 2.21; 95% CI, 1.53-3.17, P<0.001; HR after lung transplantation, 5.83; 95% CI, 3.12-10.9, P<0.001. Relative hazards were comparable in patients with asymptomatic or symptomatic CMV infection. The CMV donor or recipient serological constellation also predicted the incidence of graft rejection after liver and lung transplantation, with significantly higher rates of rejection in transplants in which donor or recipient were CMV seropositive (non-D-/R-), compared with D- transplant or R- transplant (HR, 3.05; P=0.002 for liver and HR, 2.42; P=0.01 for lung transplants). Finally, graft loss occurred more frequently in non-D- or non-R- compared with D- transplant or R- transplant in all organs analyzed. Valganciclovir prophylactic treatment seemed to delay, but not prevent, graft loss in non-D- or non-R- transplants. CONCLUSION Cytomegalovirus replication and donor or recipient seroconstellation remains associated with graft rejection and graft loss in the era of prophylactic CMV treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the relation between ethnically based rejection sensitivity and academic achievement in a sample of 936 immigrant students in Germany and Switzerland. The theory of race-based rejection sensitivity that originated in North America was extended to immigrant students in Europe. The rough political climate against immigrants in Europe makes it probable that immigrant youth face particular difficulties and are affected by ethnically based rejection sensitivity, at least as much as—or even more than—minority youth in the United States. Using a standardized literacy performance test and multilevel analyses, we found that ethnically based rejection sensitivity was negatively related to academic achievement for immigrant students. This relation was partially mediated by a strong contingency of the students' self-worth on the heritage culture, as well as by a low number of native German or Swiss majority-group friends. We interpret these processes as immigrant students' efforts to cope with ethnically based rejection sensitivity by retracting into their heritage culture and avoiding majority-group contact, which unfortunately, however, at the same time also results in lower academic achievement. Copyright © 2014 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end. The proposed algorithm shifts the baseline level of the ECG signal to the middle of the dynamic input range. Due to the fast offset shifts, that produce much steeper signal portions than the normal ECG waves, the true ECG signal can be reconstructed offline and filtered using computationally intensive algorithms. Based on Monte Carlo simulations we observed reconstruction errors mainly caused by the non-linearity inaccuracies of the DAC. However, the signal to error ratio of the BWT is higher compared to an analog front-end featuring a dynamic input ranges above 15 mV if a synthetic ECG signal was used. The BWT is additionally able to suppress (electrode) offset potentials without introducing long transients. Due to its structural simplicity, memory efficiency and the DC coupling capability, the BWT is dedicated to high integration required in long-term and low-power ECG recording systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed ultrasound tomography in echo-mode (CUTE) allows imaging the speed of sound inside tissue using hand-held pulse-echo ultrasound. This technique is based on measuring the changing local phase of beamformed echoes when changing the transmit beam steering angle. Phantom results have shown a spatial resolution and contrast that could qualify CUTE as a promising novel diagnostic modality in combination with B-mode ultrasound. Unfortunately, the large intensity range of several tens of dB that is encountered in clinical images poses difficulties to echo phase tracking and results in severe artefacts. In this paper we propose a modification to the original technique by which more robust echo tracking can be achieved, and we demonstrate in phantom experiments that dynamic range artefacts are largely eliminated. Dynamic range artefact reduction also allowed for the first time a clinical implementation of CUTE with sufficient contrast to reproducibly distinguish the different speed of sound in different tissue layers of the abdominal wall and the neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS A non-invasive gene-expression profiling (GEP) test for rejection surveillance of heart transplant recipients originated in the USA. A European-based study, Cardiac Allograft Rejection Gene Expression Observational II Study (CARGO II), was conducted to further clinically validate the GEP test performance. METHODS AND RESULTS Blood samples for GEP testing (AlloMap(®), CareDx, Brisbane, CA, USA) were collected during post-transplant surveillance. The reference standard for rejection status was based on histopathology grading of tissue from endomyocardial biopsy. The area under the receiver operating characteristic curve (AUC-ROC), negative (NPVs), and positive predictive values (PPVs) for the GEP scores (range 0-39) were computed. Considering the GEP score of 34 as a cut-off (>6 months post-transplantation), 95.5% (381/399) of GEP tests were true negatives, 4.5% (18/399) were false negatives, 10.2% (6/59) were true positives, and 89.8% (53/59) were false positives. Based on 938 paired biopsies, the GEP test score AUC-ROC for distinguishing ≥3A rejection was 0.70 and 0.69 for ≥2-6 and >6 months post-transplantation, respectively. Depending on the chosen threshold score, the NPV and PPV range from 98.1 to 100% and 2.0 to 4.7%, respectively. CONCLUSION For ≥2-6 and >6 months post-transplantation, CARGO II GEP score performance (AUC-ROC = 0.70 and 0.69) is similar to the CARGO study results (AUC-ROC = 0.71 and 0.67). The low prevalence of ACR contributes to the high NPV and limited PPV of GEP testing. The choice of threshold score for practical use of GEP testing should consider overall clinical assessment of the patient's baseline risk for rejection.