62 resultados para Anesthetics, Inhalation
Resumo:
A transmission electron microscope (TEM) accessory, the energy filter, enables the establishment of a method for elemental microanalysis, the electron energy-loss spectroscopy (EELS). In conventional TEM, unscattered, elastic, and inelastic scattered electrons contribute to image information. Energy-filtering TEM (EFTEM) allows elemental analysis at the ultrastructural level by using selected inelastic scattered electrons. EELS is an excellent method for elemental microanalysis and nanoanalysis with good sensitivity and accuracy. However, it is a complex method whose potential is seldom completely exploited, especially for biological specimens. In addition to spectral analysis, parallel-EELS, we present two different imaging techniques in this chapter, namely electron spectroscopic imaging (ESI) and image-EELS. We aim to introduce these techniques in this chapter with the elemental microanalysis of titanium. Ultrafine, 22-nm titanium dioxide particles are used in an inhalation study in rats to investigate the distribution of nanoparticles in lung tissue.
Resumo:
We combined two techniques, radiolabeled aerosol inhalation delivery and induced sputum, to examine in vivo the time course of particle uptake by airway macrophages in 10 healthy volunteers. On three separate visits, induced sputum was obtained 40, 100, and 160 min after inhalation of radiolabeled sulfur colloid (SC) aerosol (Tc99 m-SC, 0.2 microm colloid size delivered in 6-microm droplets). On a fourth visit (control) with no SC inhalation, induced sputum was obtained and SC particles were incubated (37 degrees C) in vitro with sputum cells for 40, 100, and 160 min (matching the times associated with in vivo sampling). Total and differential cell counts were recorded for each sputum sample. Compared with 40 min (6 +/- 3%), uptake in vivo was significantly elevated at 100 (31 +/- 5%) and 160 min (27 +/- 4%); both were strongly associated with the number of airway macrophages (R = 0.8 and 0.7, respectively); and the number and proportion of macrophages at 40 min were significantly (P < 0.05) elevated compared with control (1,248 +/- 256 versus 555 +/- 114 cells/mg; 76 +/- 6% versus 60 +/- 5%). Uptake in vitro increased in a linear fashion over time and was maximal at 160 min (40 min, 12 +/- 2%; 100 min, 16 +/- 4%; 160 min, 24 +/- 6%). These data suggest that airway surface macrophages in healthy subjects rapidly engulf insoluble particles. Further, macrophage recruitment and phagocytosis-modifying agents are factors in vivo that likely affect particle uptake and its time course.
Resumo:
Interleukin-8 (IL-8) activates neutrophils via the chemokine receptors CXCR1 and CXCR2. However, the airways of individuals with cystic fibrosis are frequently colonized by bacterial pathogens, despite the presence of large numbers of neutrophils and IL-8. Here we show that IL-8 promotes bacterial killing by neutrophils through CXCR1 but not CXCR2. Unopposed proteolytic activity in the airways of individuals with cystic fibrosis cleaved CXCR1 on neutrophils and disabled their bacterial-killing capacity. These effects were protease concentration-dependent and also occurred to a lesser extent in individuals with chronic obstructive pulmonary disease. Receptor cleavage induced the release of glycosylated CXCR1 fragments that were capable of stimulating IL-8 production in bronchial epithelial cells via Toll-like receptor 2. In vivo inhibition of proteases by inhalation of alpha1-antitrypsin restored CXCR1 expression and improved bacterial killing in individuals with cystic fibrosis. The cleavage of CXCR1, the functional consequences of its cleavage, and the identification of soluble CXCR1 fragments that behave as bioactive components represent a new pathophysiologic mechanism in cystic fibrosis and other chronic lung diseases.
Resumo:
Combustion-derived and synthetic nano-sized particles (NSP) have gained considerable interest among pulmonary researchers and clinicians for two main reasons: 1) Inhalation exposure to combustion-derived NSP was associated with increased pulmonary and cardiovascular morbidity and mortality as suggested by epidemiological studies. Experimental evidence has provided a mechanistic picture of the adverse health effects associated with inhalation of combustion-derived and synthetic NSP. 2) The toxicological potential of NSP contrasts with the potential application of synthetic NSP in technological as well as medicinal settings with the latter including the use of NSP as diagnostics or therapeutics. In order to shed light on this paradox, this article aims to highlight recent findings about the interaction of inhaled NSP with the structures of the respiratory tract including surfactant and alveolar macrophages and epithelial cells. Cellular responses to NSP exposure include the generation of reactive oxygen species and the induction of an inflammatory response. Furthermore, this review places special emphasis on methodological differences between experimental studies and the caveats associated with the dose metrics and points out ways to overcome inherent methodological problems. Key words: electron tomography, surfactant, translocation, oxidative stress, inflammation.
Resumo:
The role of macrophages in the clearance of particles with diameters less than 100 nm (ultrafine or nanoparticles) is not well established, although these particles deposit highly efficiently in peripheral lungs, where particle phagocytosis by macrophages is the primary clearance mechanism. To investigate the uptake of nanoparticles by lung phagocytes, we analyzed the distribution of titanium dioxide particles of 20 nm count median diameter in macrophages obtained by bronchoalveolar lavage at 1 hour and 24 hours after a 1-hour aerosol inhalation. Differential cell counts revealing greater than 96% macrophages and less than 1% neutrophils and lymphocytes excluded inflammatory cell responses. Employing energy-filtering transmission electron microscopy (EFTEM) for elemental microanalysis, we examined 1,594 macrophage profiles in the 1-hour group (n = 6) and 1,609 in the 24-hour group (n = 6). We found 4 particles in 3 macrophage profiles at 1 hour and 47 particles in 27 macrophage profiles at 24 hours. Model-based data analysis revealed an uptake of 0.06 to 0.12% ultrafine titanium-dioxide particles by lung-surface macrophages within 24 hours. Mean (SD) particle diameters were 31 (8) nm at 1 hour and 34 (10) nm at 24 hours. Particles were localized adjacent (within 13-83 nm) to the membrane in vesicles with mean (SD) diameters of 592 (375) nm at 1 hour and 414 (309) nm at 24 hours, containing other material like surfactant. Additional screening of macrophage profiles by conventional TEM revealed no evidence for agglomerated nanoparticles. These results give evidence for a sporadic and rather unspecific uptake of TiO(2)-nanoparticles by lung-surface macrophages within 24 hours after their deposition, and hence for an insufficient role of the key clearance mechanism in peripheral lungs.
Resumo:
A 20-year retrospective study of inhalant deaths in South Australia, autopsied at Forensic Science SA, was undertaken from January 1983 to December 2002. Thirty-nine cases were identified from an autopsy pool of 18,880 cases, with a male to female ratio of 12:1. Sixty-four percent of the victims (N = 25) died during voluntary inhalation of volatile substances and 28% (N = 11) committed suicide utilizing a volatile substance or gas. The remaining 3 cases involved a workplace accident (N = 1) and 2 cases of autoerotic death where inhalants were being used to augment solitary sexual activity. The mean age of the 28 victims of accidental inhalant death of 21 years (range, 13-45 years) was considerably less than that of the 11 suicide victims of 31.5 years (range, 17-48 years). No homicides were found. Approximately one quarter of the victims were Aboriginal (N = 11), 10 of whom had died as a result of gasoline inhalation ("petrol sniffing"). Other common substances of abuse were aliphatic hydrocarbons such as butane. The study has shown that those most at risk for accidental or suicidal inhalant deaths were young males, with 92% of victims overall being male, and with 77% of victims being under 31 years of age. Gasoline inhalation remains a significant problem in Aboriginal communities in South Australia.
Resumo:
BACKGROUND: The Anesthetic Conserving Device (AnaConDa) uncouples delivery of a volatile anesthetic (VA) from fresh gas flow (FGF) using a continuous infusion of liquid volatile into a modified heat-moisture exchanger capable of adsorbing VA during expiration and releasing adsorbed VA during inspiration. It combines the simplicity and responsiveness of high FGF with low agent expenditures. We performed in vitro characterization of the device before developing a population pharmacokinetic model for sevoflurane administration with the AnaConDa, and retrospectively testing its performance (internal validation). MATERIALS AND METHODS: Eighteen females and 20 males, aged 31-87, BMI 20-38, were included. The end-tidal concentrations were varied and recorded together with the VA infusion rates into the device, ventilation and demographic data. The concentration-time course of sevoflurane was described using linear differential equations, and the most suitable structural model and typical parameter values were identified. The individual pharmacokinetic parameters were obtained and tested for covariate relationships. Prediction errors were calculated. RESULTS: In vitro studies assessed the contribution of the device to the pharmacokinetic model. In vivo, the sevoflurane concentration-time courses on the patient side of the AnaConDa were adequately described with a two-compartment model. The population median absolute prediction error was 27% (interquartile range 13-45%). CONCLUSION: The predictive performance of the two-compartment model was similar to that of models accepted for TCI administration of intravenous anesthetics, supporting open-loop administration of sevoflurane with the AnaConDa. Further studies will focus on prospective testing and external validation of the model implemented in a target-controlled infusion device.
Resumo:
BACKGROUND: Several epidemiological studies show that inhalation of particulate matter may cause increased pulmonary morbidity and mortality. Of particular interest are the ultrafine particles that are particularly toxic. In addition more and more nanoparticles are released into the environment; however, the potential health effects of these nanoparticles are yet unknown. OBJECTIVES: To avoid particle toxicity studies with animals many cell culture models have been developed during the past years. METHODS: This review focuses on the most commonly used in vitro epithelial airway and alveolar models to study particle-cell interactions and particle toxicity and highlights advantages and disadvantages of the different models. RESULTS/CONCLUSION: There are many lung cell culture models but none of these models seems to be perfect. However, they might be a great tool to perform basic research or toxicity tests. The focus here is on 3D and co-culture models, which seem to be more realistic than monocultures.
Resumo:
Anthropogenic nano-sized particles (NSP), ie, particles with a diameter of less than 100 nm, are generated with or without purpose as chemically and physically well-defined materials or as a consequence of combustion processes respectively. Inhalation of NSP occurs on a regular basis due to air pollution and is associated with an increase in respiratory and cardiovascular morbidity and mortality. Manufactured NSP may intentionally be inhaled as pharmaceuticals or unintentionally during production at the workplace. Hence the interactions of NSP with the respiratory tract are currently under intensive investigation. Due to special physicochemical features of NSP, its biological behaviour may differ from that of larger sized particles. Here we review two important themes of current research into the effects of NSP on the lungs: 1) The potential of NSP to cross the blood-air barrier of the lungs, thus gaining access to the circulation and extrapulmonary organs. It is currently accepted that a small fraction of inhaled NSP may translocate to the circulation. The significance of this translocation requires further research. 2) The entering mechanisms of NSP into different cell types. There is evidence that NSP are taken up by cells via well-known pathways of endocytosis but also via different mechanisms not well understood so far. Knowledge of the quantitative relationship between the different entering mechanisms and cellular responses is not yet available but is urgently needed in order to understand the effects of intentionally or unintentionally inhaled NSP on the respiratory tract.
Resumo:
BACKGROUND: The noble gas helium is devoid of anesthetic effects, and it elicits cardiac preconditioning. We hypothesized that inhalation of helium provides protection against postocclusive endothelial dysfunction after ischemia-reperfusion of the forearm in humans. METHODS: Eight healthy male subjects were enrolled in this study with a crossover design. Each volunteer was randomly exposed to 15 min of forearm ischemia in the presence or absence of helium inhalation. Helium was inhaled at an end-tidal concentration of 50 vol% from 15 min before ischemia until 5 min after the onset of reperfusion ("helium conditioning"). Hyperemic reaction, a marker of nitric oxide bioavailability and endothelial function, was determined at 15 and 30 min of reperfusion on the forearm using venous occlusion plethysmography. Expression of the proinflammatory markers CD11b, ICAM-1, PSGL-1, and L-selectin (CD62L) on leukocytes and P-selectin (CD62P), PSGL-1, and CD42b on platelets were measured by flow cytometry during reperfusion. RESULTS: Ischemia-reperfusion consistently reduced the postocclusive endothelium-dependent hyperemic reaction at 15 and 30 min of reperfusion. Periischemic inhalation of helium at 50 vol% did not improve postocclusive hyperemic reaction. Helium decreased expression of the proinflammatory marker CD11b and ICAM-1 on leukocytes and attenuated the expression of the procoagulant markers CD42b and PSGL-1 on platelets. CONCLUSIONS: Although inhalation of helium diminished the postischemic inflammatory reaction, our data indicate that human endothelium, which is a component of all vital organs, is not amenable to protection by helium at 50 vol% in vivo. This is in contrast to sevoflurane, which protects human endothelium at low subanesthetic concentrations.
Resumo:
BACKGROUND AND OBJECTIVES: Nerve blocks using local anesthetics are widely used. High volumes are usually injected, which may predispose patients to associated adverse events. Introduction of ultrasound guidance facilitates the reduction of volume, but the minimal effective volume is unknown. In this study, we estimated the 50% effective dose (ED50) and 95% effective dose (ED95) volume of 1% mepivacaine relative to the cross-sectional area of the nerve for an adequate sensory block. METHODS: To reduce the number of healthy volunteers, we used a volume reduction protocol using the up-and-down procedure according to the Dixon average method. The ulnar nerve was scanned at the proximal forearm, and the cross-sectional area was measured by ultrasound. In the first volunteer, a volume of 0.4 mL/mm of nerve cross-sectional area was injected under ultrasound guidance in close proximity to and around the nerve using a multiple injection technique. The volume in the next volunteer was reduced by 0.04 mL/mm in case of complete blockade and augmented by the same amount in case of incomplete sensory blockade within 20 mins. After 3 up-and-down cycles, ED50 and ED95 were estimated. Volunteers and physicians performing the block were blinded to the volume used. RESULTS: A total 17 of volunteers were investigated. The ED50 volume was 0.08 mL/mm (SD, 0.01 mL/mm), and the ED95 volume was 0.11 mL/mm (SD, 0.03 mL/mm). The mean cross-sectional area of the nerves was 6.2 mm (1.0 mm). CONCLUSIONS: Based on the ultrasound measured cross-sectional area and using ultrasound guidance, a mean volume of 0.7 mL represents the ED95 dose of 1% mepivacaine to block the ulnar nerve at the proximal forearm.
Resumo:
The aim of the present study was to develop a physiologically compatible inhalation solution of delta-9-tetrahydrocannabinol (THC), and to compare the pharmacokinetic and analgesic properties of pulmonal THC versus pulmonal placebo and intravenous (iv) THC, respectively. Eight healthy volunteers were included in this randomized, double-blind, crossover study. The aqueous THC formulations were prepared by using a solubilization technique. iv THC (0.053 mg/kg body weight), pulmonal THC (0.053 mg/kg), or a placebo inhalation solution was administered as single dose. At defined time points, blood samples were collected, and somatic and psychotropic side effects as well as vital functions monitored. An ice water immersion test was performed to measure analgesia. Using a pressure-driven nebulizer, the pulmonal administration of the THC liquid aerosol resulted in high THC peak plasma levels within minutes. The bioavailability of the pulmonal THC was 28.7 +/- 8.2% (mean +/- SEM). The side effects observed after pulmonal THC were coughing and slight irritation of the upper respiratory tract, very mild psychotropic symptoms, and headache. The side effects after iv THC were much more prominent. Neither pulmonal nor iv THC significantly reduced experimentally induced pain.
Resumo:
The objectives of this study were a description of the practical implementation of the painless castration under inhalational anaesthesia with an objective assessment of animal welfare, workplace safety and time exposure. 600 questionnaires were sent to farmers all over Switzerland and 100 farms were visited during castration under inhalation anaesthesia. 44 % of the visited farmers administered analgetics during anaesthesia or less than 10 minutes before castration. 14 % of the piglets were insufficiently anaesthetised (moving or vocalising) and 18 % showed stronger bleeding tendency after castration. The mortality rate was less than 0.1 %. 22 % of the swine farmers reported headache or dizziness during or after castration work. The Isoflurane level on 2 farms was above the Swiss safety limits. The time needed for castration was with 4.3 minutes clearly above the time necessary without anaesthesia. The additional financial costs and time are at the moment not adequately compensated to the farmers.
Resumo:
OBJECTIVES Sonographic guidance for peripheral nerve anesthesia has proven increasingly successful in clinical practice; however, fears that a change to sonographically guided regional anesthesia may impair the block quality and operating room work flow persist in certain units. In this retrospective cohort study, block quality and patient satisfaction during the transition period from nerve stimulator to sonographic guidance for axillary brachial plexus anesthesia in a tertiary referral center were investigated. METHODS Anesthesia records of all patients who had elective surgery of the wrist or hand during the transition time (September 1, 2006-August 25, 2007) were reviewed for block success, placement time, anesthesiologist training level, local anesthetic volume, and requirement of additional analgesics. Postoperative records were reviewed, and patient satisfaction was assessed by telephone interviews in matched subgroups. RESULTS Of 415 blocks, 341 were sonographically guided, and 74 were nerve stimulator guided. Sonographically guided blocks were mostly performed by novices, whereas nerve stimulator-guided blocks were performed by advanced users (72.3% versus 14%; P < .001). Block performance times and success rates were similar in both groups. In sonographically guided blocks, significantly less local anesthetics were applied compared to nerve stimulator-guided blocks (mean ± SD, 36.1 ± 7.1 versus 43.9 ± 6.1 mL; P< .001), and less opioids were required (fentanyl, 66.1 ± 30 versus 90 ± 62 μg; P< .001). Interviewed patients reported significantly less procedure-related discomfort, pain, and prolonged procedure time when block placement was sonographically guided (2% versus 20%; P = .002). CONCLUSIONS Transition from nerve stimulator to sonographic guidance for axillary brachial plexus blocks did not change block performance times or success rates. Patient satisfaction was improved even during the early institutional transition period.