35 resultados para Alkaline extraction and molbydate blue spectrophotometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Importance In treatment-resistant schizophrenia, clozapine is considered the standard treatment. However, clozapine use has restrictions owing to its many adverse effects. Moreover, an increasing number of randomized clinical trials (RCTs) of other antipsychotics have been published. Objective To integrate all the randomized evidence from the available antipsychotics used for treatment-resistant schizophrenia by performing a network meta-analysis. Data Sources MEDLINE, EMBASE, Biosis, PsycINFO, PubMed, Cochrane Central Register of Controlled Trials, World Health Organization International Trial Registry, and clinicaltrials.gov were searched up to June 30, 2014. Study Selection At least 2 independent reviewers selected published and unpublished single- and double-blind RCTs in treatment-resistant schizophrenia (any study-defined criterion) that compared any antipsychotic (at any dose and in any form of administration) with another antipsychotic or placebo. Data Extraction and Synthesis At least 2 independent reviewers extracted all data into standard forms and assessed the quality of all included trials with the Cochrane Collaboration's risk-of-bias tool. Data were pooled using a random-effects model in a Bayesian setting. Main Outcomes and Measures The primary outcome was efficacy as measured by overall change in symptoms of schizophrenia. Secondary outcomes included change in positive and negative symptoms of schizophrenia, categorical response to treatment, dropouts for any reason and for inefficacy of treatment, and important adverse events. Results Forty blinded RCTs with 5172 unique participants (71.5% men; mean [SD] age, 38.8 [3.7] years) were included in the analysis. Few significant differences were found in all outcomes. In the primary outcome (reported as standardized mean difference; 95% credible interval), olanzapine was more effective than quetiapine (-0.29; -0.56 to -0.02), haloperidol (-0. 29; -0.44 to -0.13), and sertindole (-0.46; -0.80 to -0.06); clozapine was more effective than haloperidol (-0.22; -0.38 to -0.07) and sertindole (-0.40; -0.74 to -0.04); and risperidone was more effective than sertindole (-0.32; -0.63 to -0.01). A pattern of superiority for olanzapine, clozapine, and risperidone was seen in other efficacy outcomes, but results were not consistent and effect sizes were usually small. In addition, relatively few RCTs were available for antipsychotics other than clozapine, haloperidol, olanzapine, and risperidone. The most surprising finding was that clozapine was not significantly better than most other drugs. Conclusions and Relevance Insufficient evidence exists on which antipsychotic is more efficacious for patients with treatment-resistant schizophrenia, and blinded RCTs-in contrast to unblinded, randomized effectiveness studies-provide little evidence of the superiority of clozapine compared with other second-generation antipsychotics. Future clozapine studies with high doses and patients with extremely treatment-refractory schizophrenia might be most promising to change the current evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The objective was to determine the risk of stroke associated with subclinical hypothyroidism. DATA SOURCES AND STUDY SELECTION Published prospective cohort studies were identified through a systematic search through November 2013 without restrictions in several databases. Unpublished studies were identified through the Thyroid Studies Collaboration. We collected individual participant data on thyroid function and stroke outcome. Euthyroidism was defined as TSH levels of 0.45-4.49 mIU/L, and subclinical hypothyroidism was defined as TSH levels of 4.5-19.9 mIU/L with normal T4 levels. DATA EXTRACTION AND SYNTHESIS We collected individual participant data on 47 573 adults (3451 subclinical hypothyroidism) from 17 cohorts and followed up from 1972-2014 (489 192 person-years). Age- and sex-adjusted pooled hazard ratios (HRs) for participants with subclinical hypothyroidism compared to euthyroidism were 1.05 (95% confidence interval [CI], 0.91-1.21) for stroke events (combined fatal and nonfatal stroke) and 1.07 (95% CI, 0.80-1.42) for fatal stroke. Stratified by age, the HR for stroke events was 3.32 (95% CI, 1.25-8.80) for individuals aged 18-49 years. There was an increased risk of fatal stroke in the age groups 18-49 and 50-64 years, with a HR of 4.22 (95% CI, 1.08-16.55) and 2.86 (95% CI, 1.31-6.26), respectively (p trend 0.04). We found no increased risk for those 65-79 years old (HR, 1.00; 95% CI, 0.86-1.18) or ≥ 80 years old (HR, 1.31; 95% CI, 0.79-2.18). There was a pattern of increased risk of fatal stroke with higher TSH concentrations. CONCLUSIONS Although no overall effect of subclinical hypothyroidism on stroke could be demonstrated, an increased risk in subjects younger than 65 years and those with higher TSH concentrations was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To systematically review the available literature on the influence of dental implant placement and loading protocols on peri-implant innervation. MATERIAL AND METHODS The database MEDLINE, Cochrane, EMBASE, Web of Science, LILACS, OpenGrey and hand searching were used to identify the studies published up to July 2013, with a populations, exposures and outcomes (PEO) search strategy using MeSH keywords, focusing on the question: Is there, and if so, what is the effect of time between tooth extraction and implant placement or implant loading on neural fibre content in the peri-implant hard and soft tissues? RESULTS Of 683 titles retrieved based on the standardized search strategy, only 10 articles fulfilled the inclusion criteria, five evaluating the innervation of peri-implant epithelium, five elucidating the sensory function in peri-implant bone. Three included studies were considered having a methodology of medium quality and the rest were at low quality. All those papers reported a sensory innervation around osseointegrated implants, either in the bone-implant interface or peri-implant epithelium, which expressed a particular innervation pattern. Compared to unloaded implants or extraction sites without implantation, a significant higher density of nerve fibres around loaded dental implants was confirmed. CONCLUSIONS To date, the published literature describes peri-implant innervation with a distinct pattern in hard and soft tissues. Implant loading seems to increase the density of nerve fibres in peri-implant tissues, with insufficient evidence to distinguish between the innervation patterns following immediate and delayed implant placement and loading protocols. Variability in study design and loading protocols across the literature and a high risk of bias in the studies included may contribute to this inconsistency, revealing the need for more uniformity in reporting, randomized controlled trials, longer observation periods and standardization of protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-energy e(-) and pi(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% +/- 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% +/- 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution. (C) 2015 AIP Publishing LLC.