34 resultados para Accelerated storages
Resumo:
OBJECTIVE The aim was to develop a delineation guideline for target definition for APBI or boost by consensus of the Breast Working Group of GEC-ESTRO. PROPOSED RECOMMENDATIONS Appropriate delineation of CTV (PTV) with low inter- and intra-observer variability in clinical practice is complex and needs various steps as: (1) Detailed knowledge of primary surgical procedure, of all details of pathology, as well as of preoperative imaging. (2) Definition of tumour localization before breast conserving surgery inside the breast and translation of this information in the postoperative CT imaging data set. (3) Calculation of the size of total safety margins. The size should be at least 2 cm. (4) Definition of the target. (5) Delineation of the target according to defined rules. CONCLUSION Providing guidelines based on the consensus of a group of experts should make it possible to achieve a reproducible and consistent definition of CTV (PTV) for Accelerated Partial Breast Irradiation (APBI) or boost irradiation after breast conserving closed cavity surgery, and helps to define it after selected cases of oncoplastic surgery.
Resumo:
BACKGROUND In a phase 3, randomised, non-inferiority trial, accelerated partial breast irradiation (APBI) for patients with stage 0, I, and IIA breast cancer who underwent breast-conserving treatment was compared with whole-breast irradiation. Here, we present 5-year follow-up results. METHODS We did a phase 3, randomised, non-inferiority trial at 16 hospitals and medical centres in seven European countries. 1184 patients with low-risk invasive and ductal carcinoma in situ treated with breast-conserving surgery were centrally randomised to either whole-breast irradiation or APBI using multicatheter brachytherapy. The primary endpoint was local recurrence. Analysis was done according to treatment received. This trial is registered with ClinicalTrials.gov, number NCT00402519. FINDINGS Between April 20, 2004, and July 30, 2009, 551 patients had whole-breast irradiation with tumour-bed boost and 633 patients received APBI using interstitial multicatheter brachytherapy. At 5-year follow-up, nine patients treated with APBI and five patients receiving whole-breast irradiation had a local recurrence; the cumulative incidence of local recurrence was 1·44% (95% CI 0·51-2·38) with APBI and 0·92% (0·12-1·73) with whole-breast irradiation (difference 0·52%, 95% CI -0·72 to 1·75; p=0·42). No grade 4 late side-effects were reported. The 5-year risk of grade 2-3 late side-effects to the skin was 3·2% with APBI versus 5·7% with whole-breast irradiation (p=0·08), and 5-year risk of grade 2-3 subcutaneous tissue late side-effects was 7·6% versus 6·3% (p=0·53). The risk of severe (grade 3) fibrosis at 5 years was 0·2% with whole-breast irradiation and 0% with APBI (p=0·46). INTERPRETATION The difference between treatments was below the relevance margin of 3 percentage points. Therefore, adjuvant APBI using multicatheter brachytherapy after breast-conserving surgery in patients with early breast cancer is not inferior to adjuvant whole-breast irradiation with respect to 5-year local control, disease-free survival, and overall survival. FUNDING German Cancer Aid.
Resumo:
OBJECTIVES Readout-segmented echo planar imaging (rs-EPI) significantly reduces susceptibility artifacts in diffusion-weighted imaging (DWI) of the breast compared to single-shot EPI but is limited by longer scan times. To compensate for this, we tested a new simultaneous multi-slice (SMS) acquisition for accelerated rs-EPI. MATERIALS AND METHODS After approval by the local ethics committee, eight healthy female volunteers (age, 38.9±13.1 years) underwent breast MRI at 3T. Conventional as well as two-fold (2× SMS) and three-fold (3× SMS) slice-accelerated rs-EPI sequences were acquired at b-values of 50 and 800s/mm(2). Two independent readers analyzed the apparent diffusion coefficient (ADC) in fibroglandular breast parenchyma. The signal-to-noise ratio (SNR) was estimated based on the subtraction method. ADC and SNR were compared between sequences by using the Friedman test. RESULTS The acquisition time was 4:21min for conventional rs-EPI, 2:35min for 2× SMS rs-EPI and 1:44min for 3× SMS rs-EPI. ADC values were similar in all sequences (mean values 1.62×10(-3)mm(2)/s, p=0.99). Mean SNR was 27.7-29.6, and no significant differences were found among the sequences (p=0.83). CONCLUSION SMS rs-EPI yields similar ADC values and SNR compared to conventional rs-EPI at markedly reduced scan time. Thus, SMS excitation increases the clinical applicability of rs-EPI for DWI of the breast.
Resumo:
PURPOSE To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.