55 resultados para 24 hour measurement


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Arginine vasopressin (AVP) has a key role in osmoregulation by facilitating water transport in the collecting duct. Recent evidence suggests that AVP may have additional effects on renal function and favor cyst growth in polycystic kidney disease. Whether AVP also affects kidney structure in the general population is unknown. We analyzed the association of copeptin, an established surrogate for AVP, with parameters of renal function and morphology in a multicentric population-based cohort. Participants from families of European ancestry were randomly selected in three Swiss cities. We used linear multilevel regression analysis to explore the association of copeptin with renal function parameters as well as kidney length and the presence of simple renal cysts assessed by ultrasound examination. Copeptin levels were log-transformed. The 529 women and 481 men had median copeptin levels of 3.0 and 5.2 pmol/L, respectively (P<0.001). In multivariable analyses, the copeptin level was associated inversely with eGFR (β=-2.1; 95% confidence interval [95% CI], -3.3 to -0.8; P=0.002) and kidney length (β=-1.2; 95% CI, -1.9 to -0.4; P=0.003) but positively with 24-hour urinary albumin excretion (β=0.11; 95% CI, 0.01 to 0.20; P=0.03) and urine osmolality (β=0.08; 95% CI, 0.05 to 0.10; P<0.001). A positive association was found between the copeptin level and the presence of renal cysts (odds ratio, 1.6; 95% CI, 1.1 to 2.4; P=0.02). These results suggest that AVP has a pleiotropic role in renal function and may favor the development of simple renal cysts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values <0.040). Similar inverse associations were observed for paraxanthine and theophylline. Adjusted night-time systolic blood pressure in the first (lowest), second, third, and fourth (highest) quartile of paraxanthine urinary excretions were 110.3, 107.3, 107.3, and 105.1 mm Hg, respectively (P trend <0.05). No associations of urinary excretions with diastolic blood pressure were generally found, and theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A successful pregnancy requires an accommodating environment. Salt and water availability are critical for plasma volume expansion. Any changes in sodium intake would alter aldosterone, a hormone previously described beneficial in pregnancy. To date, it remains ambiguous whether high aldosterone or high salt intake is preferable. We hypothesized that increased aldosterone is a rescue mechanism and appropriate salt availability is equally effective in maintaining a normotensive blood pressure (BP) phenotype in pregnancy. We compared normotensive pregnant women (n=31) throughout pregnancy with young healthy female individuals (n=31–62) and performed salt sensitivity testing within the first trimester. Suppression of urinary tetrahydro-aldosterone levels by salt intake as measured by gas chromatography–mass spectrometry and urinary sodium excretion corrected for creatinine, respectively, was shifted toward a higher salt intake in pregnancy (P<0.0001). In pregnancy, neither high urinary tetrahydro-aldosterone nor sodium excretion was correlated with higher BP. In contrast, in nonpregnant women, systolic BP rose with aldosterone (P<0.05). Testing the impact of salt on BP, we performed salt sensitivity testing in a final cohort of 19 pregnant and 24 nonpregnant women. On salt loading, 24-hour mean arterial pressure rose by 3.6±1.5 and dropped by –2.8±1.5 mm Hg favoring pregnant women (P<0.01; χ2=6.04; P<0.02). Our data suggest first that salt responsiveness of aldosterone is alleviated in conditions of pregnancy without causing aldosterone-induced hypertension. Second, salt seems to aid in BP lowering in pregnancy for reasons incompletely elucidated, yet involving renin suppression and potentially placental sensing mechanisms. Further research should identify susceptible individuals and clarify effector mechanisms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE Vitamin D (D₃) status is reported to correlate negatively with insulin production and insulin sensitivity in patients with type 2 diabetes mellitus (T2DM). However, few placebo-controlled intervention data are available. We aimed to assess the effect of large doses of parenteral D3 on glycosylated haemoglobin (HbA(₁c)) and estimates of insulin action (homeostasis model assessment insulin resistance: HOMA-IR) in patients with stable T2DM. MATERIALS AND METHODS We performed a prospective, randomised, double-blind, placebo-controlled pilot study at a single university care setting in Switzerland. Fifty-five patients of both genders with T2DM of more than 10 years were enrolled and randomised to either 300,000 IU D₃ or placebo, intramuscularly. The primary endpoint was the intergroup difference in HbA(₁c) levels. Secondary endpoints were: changes in insulin sensitivity, albuminuria, calcium/phosphate metabolism, activity of the renin-aldosterone axis and changes in 24-hour ambulatory blood pressure values. RESULTS After 6 months of D₃ supply, there was a significant intergroup difference in the change in HbA(₁c) levels (relative change [mean ± standard deviation] +2.9% ± 1.5% in the D₃ group vs +6.9% ± 2.1% the in placebo group, p = 0.041) as HOMA-IR decreased by 12.8% ± 5.6% in the D₃ group and increased by 10% ± 5.4% in the placebo group (intergroup difference, p = 0.032). Twenty-four-hour urinary albumin excretion decreased in the D₃ group from 200 ± 41 to 126 ± 39, p = 0.021). There was no significant intergroup difference for the other secondary endpoints. CONCLUSIONS D₃ improved insulin sensitivity (based on HOMA-IR) and affected the course of HbA(₁c) positively compared with placebo in patients with T2DM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

UNLABELLED This study aimed to assess the safety and effectiveness of renal denervation using the Symplicity system in real-world patients with uncontrolled hypertension (NCT01534299). The Global SYMPLICITY Registry is a prospective, open-label, multicenter registry. Office and 24-hour ambulatory blood pressures (BPs) were measured. Change from baseline to 6 months was analyzed for all patients and for subgroups based on baseline office systolic BP, diabetic status, and renal function; a cohort with severe hypertension (office systolic pressure, ≥160 mm Hg; 24-hour systolic pressure, ≥135 mm Hg; and ≥3 antihypertensive medication classes) was also included. The analysis included protocol-defined safety events. Six-month outcomes for 998 patients, including 323 in the severe hypertension cohort, are reported. Mean baseline office systolic BP was 163.5±24.0 mm Hg for all patients and 179.3±16.5 mm Hg for the severe cohort; the corresponding baseline 24-hour mean systolic BPs were 151.5±17.0 and 159.0±15.6 mm Hg. At 6 months, the changes in office and 24-hour systolic BPs were -11.6±25.3 and -6.6±18.0 mm Hg for all patients (P<0.001 for both) and -20.3±22.8 and -8.9±16.9 mm Hg for those with severe hypertension (P<0.001 for both). Renal denervation was associated with low rates of adverse events. After the procedure through 6 months, there was 1 new renal artery stenosis >70% and 5 cases of hospitalization for a hypertensive emergency. In clinical practice, renal denervation resulted in significant reductions in office and 24-hour BPs with a favorable safety profile. Greater BP-lowering effects occurred in patients with higher baseline pressures. CLINICAL TRIAL REGISTRATION URL: www.clinicaltrials.gov. Unique identifier: NCT01534299.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES Allelic variants in UMOD, the gene coding for uromodulin, are associated with rare tubulointerstitial kidney disorders and risk of CKD and hypertension in the general population. The factors associated with uromodulin excretion in the normal population remain largely unknown, and were therefore explored in this study. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Urinary uromodulin excretion was measured using a validated ELISA in two population-based cohorts that included more than 6500 individuals. The Swiss Kidney Project on Genes in Hypertension study (SKIPOGH) included 817 adults (mean age±SD, 45±17 years) who underwent renal ultrasonography and performed a 24-hour urine collection. The Cohorte Lausannoise study included 5706 adults (mean age, 53±11 years) with fresh spot morning urine samples. We calculated eGFRs using the CKD-Epidemiology Collaboration formula and by 24-hour creatinine clearance. RESULTS In both studies, positive associations were found between uromodulin and urinary sodium, chloride, and potassium excretion and osmolality. In SKIPOGH, 24-hour uromodulin excretion (median, 41 [interquartile range, 29-57] mg/24 h) was positively associated with kidney length and volume and with creatinine excretion and urine volume. It was negatively associated with age and diabetes. Both spot uromodulin concentration and 24-hour uromodulin excretion were linearly and positively associated (multivariate analyses) with eGFR<90 ml/min per 1.73 m(2). CONCLUSION Age, creatinine excretion, diabetes, and urinary volume are independent clinical correlates of urinary uromodulin excretion. The associations of uromodulin excretion with markers of tubular functions and kidney dimensions suggest that it may reflect tubule activity in the general population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES A dissociation between behavioural (in-control) and physiological parameters (indicating loss-of-control) is associated with cardiovascular risk in defensive coping (DefS) Africans. We evaluated relationships between DefS, sub-clinical atherosclerosis, low-grade inflammation and hypercoagulation in a bi-ethnic sex cohort. METHODS Black (Africans) and white Africans (Caucasians) (n = 375; aged 44.6 ± 9.7 years) were included. Ambulatory BP, vascular structure (left carotid cross-sectional wall area (L-CSWA) and plaque counts), and markers of coagulation and inflammation were quantified. Ethnicity/coping style interaction was revealed only in DefS participants. RESULTS A hypertensive state, less plaque, low-grade inflammation, and hypercoagulation were more prevalent in DefS Africans (27-84%) than DefS Caucasians (18-41%). Regression analyses demonstrated associations between L-CSWA and 24 hour systolic BP (R(2) = 0.38; β = 0.78; p < 0.05) in DefS African men but not in DefS African women or Caucasians. No associations between L-CSWA and coagulation markers were evident. CONCLUSION Novel findings revealed hypercoagulation, low-grade inflammation and hyperkinetic BP (physiological loss-of-control responses) in DefS African men. Coupled to a self-reported in-control DefS behavioural profile, this reflects dissociation between behaviour and physiology. It may explain changes in vascular structure, increasing cerebrovascular disease risk in a state of hyper-vigilant coping.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES Cardiac involvement in the course of acute kidney injury is described in humans as cardiorenal syndrome type 3 but has received only limited attention in dogs. This study was designed to evaluate cardiac injury and dysfunction in acute kidney injury in dogs and its association with outcome. METHODS This prospective cohort study enrolled 24 client-owned dogs with acute kidney injury. Cardiac disorders were evaluated with thoracic radiographs, echocardiography, 24-hour Holter monitoring and cardiac troponin I concentrations within 2 days of admission and 7 to 10 days later. RESULTS Most dogs were diagnosed with leptospirosis (n=18, 75%) and presented with moderate-to-severe acute kidney injury, International Renal Interest Society grades III to V. Dogs with ê100 ventricular premature complexes per 24 hour in the first examination (n=8) had significantly higher initial cTnI concentrations (P=0·007) compared to dogs with fewer than 100. In receiver operating characteristic curve analysis, the number of ventricular premature complexes was predictive of outcome (AUC 0·83, P<0·001). CLINICAL SIGNIFICANCE Acute kidney injury seems to be associated with cardiac injury and arrhythmias in dogs. The data do not indicate a cardiac cause of poor outcome in dogs with increased number of ventricular premature complexes but the association may reflect the severity of disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures  Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES:: This study was designed to apply the rapid Elecsys(R) S100 immunoassay for real-time measurement of S100 protein serum levels indicating acute brain damage in patients undergoing carotid artery stenting (CAS) or endarterectomy (CEA). DESIGN AND METHODS:: Data of 14 CAS patients were compared to those of 43 CEA and 14 control patients undergoing coronary angiography (CA). S100 serum levels were measured by the full-automatic Elecsys(R) S100 immunoassay and compared to those obtained by the well-established LIA-mat(R) S100 system. RESULTS:: In contrast to CAS and CA patients, median S100 serum levels of CEA patients significantly increased to 0.24 ng/mL before declamping, but subsequently returned to baseline. Three CEA patients with neurological deficits showed sustained elevated S100 levels 6 h after extubation. Absolute S100 values were not significantly different between the two methods. Bland-Altman plot analyses displayed a good agreement, mostly indicating slightly smaller values applying the Elecsys(R) S100 system. CONCLUSIONS:: The Elecsys(R) S100 system appears to be suitable for rapid real-time detection of neurological deficits in patients undergoing CAS and CEA. Persistent elevations of Elecsys(R) S100 levels during CEA were associated with prolonged neurological disorders, whereas transient increases seem to represent impaired blood-brain barrier integrity without neurological deficits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of the study was to measure the effects of increased inspired oxygen on patients suffering severe head injury and consequent influences on the correlations between CPP and brain tissue oxygen (PtiO2) and the effects on brain microdialysate glucose and lactate. METHODS: In a prospective, observational study 20 patients suffering severe head injury (GCS< or =8) were studied between January 2000 and December 2001. Each patient received an intraparenchymal ICP device and an oxygen sensor and, in 17 patients brain microdialysis was performed at the cortical-subcortical junction. A 6 h 100% oxygen challenge (F IO2 1.0) ( Period A) was performed as early as possible in the first 24 hours after injury and compared with a similar 6 hour period following the challenge ( Period B). Statistics were performed using the linear correlation analysis, one sample t-test, as well as the Lorentzian peak correlation analysis. RESULTS: F IO2 was positively correlated with PtiO2 (p < 0.0001) over the whole study period. PtiO2 was significantly higher (p < 0.001) during Period A compared to Period B. CPP was positively correlated with PtiO2 (p < 0.001) during the whole study. PtiO2 peaked at a CPP value of 78 mmHg performing a Lorentzian peak correlation analysis of all patients over the whole study. During Period A the brain microdialysate lactate was significantly lower (p = 0.015) compared with Period B. However the brain microdialysate glucose remained unchanged. CONCLUSION: PtiO2 is significantly positively correlated with F IO2, meaning that PtiO2 can be improved by the simple manipulation of increasing F IO2 and ABGAO2. PtiO2 is positively correlated with CPP, peaking at a CPP value of 78 mmHg. Brain microdialysate lactate can be lowered by increasing PtiO2 values, as observed during the oxygen challenge, whereas microdialysate glucose is unchanged during this procedure. Extension of the oxygen challenge time and measurement of the intermediate energy metabolite pyruvate may clarify the metabolic effects of the intervention. Prospective comparative studies, including analysis of outcome on a larger multicenter basis, are necessary to assess the long term clinical benefits of this procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.