378 resultados para Pennsylvania Hospital (Philadelphia, Pa.)
Resumo:
OBJECTIVE: To investigate the hypothesis that the need for clean intermittent self-catheterization after botulinum neurotoxin type A injections is outweighed by the efficacy of this treatment, so that clean intermittent self-catheterization is not a burden for patients with refractory idiopathic detrusor overactivity. METHODS: Women undergoing intradetrusor injections of 200 units botulinum neurotoxin type A for refractory idiopathic detrusor overactivity were evaluated prospectively. Clean intermittent self-catheterization was discussed with all patients and its possible need after botulinum neurotoxin type A treatment. As indicator of quality of life, lower urinary tract symptom distress and effect on daily activities were assessed using the validated Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7) before and 4 weeks after receiving botulinum neurotoxin type A injections. RESULTS: Mean age of the 65 women was 51 years, and all voided spontaneously before botulinum neurotoxin type A injections. After botulinum neurotoxin type A treatment, 28 (43%) required clean intermittent self-catheterization. Mean UDI-6 and IIQ-7 scores reduced from 61 to 33 (P<.001) and 62 to 30 (P<.001) in women performing clean intermittent self-catheterization and from 60 to 28 (P<.001) and 64 to 25 (P<.001) in those who did not, respectively. Comparison of quality of life in women performing clean intermittent self-catheterization and in those who did not revealed no significant differences before and after botulinum neurotoxin type A treatment. CONCLUSION: Clean intermittent self-catheterization after botulinum neurotoxin type A intradetrusor injections did not impair quality of life in appropriately informed and selected women in the short term. All patients should be informed of the potential need for clean intermittent self-catheterization after botulinum neurotoxin type A injections, and a willingness to do so should be a prerequisite for this still unlicensed off-label treatment.
Resumo:
OBJECTIVE: To compare image quality and radiation dose of thoracoabdominal computed tomography (CT) angiography at 80 and 100 kVp and to assess the feasibility of reducing contrast medium volume from 60 to 45 mL at 80 kVp. MATERIALS AND METHODS: This retrospective study had institutional review board approval; informed consent was waived. Seventy-five patients who had undergone thoracoabdominal 64-section multidetector-row CT angiography were divided into 3 groups of 25 patients each. Patients of groups A (tube voltage, 100 kVp) and B (tube voltage, 80 kVp) received 60 mL of contrast medium at 4 mL/s. Patients of group C (tube voltage, 80 kVp) received 45 mL of contrast medium at 3 mL/s. Mean aortoiliac attenuation, image noise, and contrast-to-noise ratio were assessed. The measurement of radiation dose was based on the volume CT dose index. Three independent readers assessed the diagnostic image quality. RESULTS: Mean aortoiliac attenuation for group B (621.1 +/- 90.5 HU) was significantly greater than for groups A and C (485.2 +/- 110.5 HU and 483.1 +/- 119.8 HU; respectively) (P < 0.001). Mean image noise was significantly higher for groups B and C than for group A (P < 0.05). The contrast-to-noise ratio did not significantly differ between the groups (group A, 35.0 +/- 13.8; group B, 31.7 +/- 10.1; group C, 27.3 +/- 11.5; P = 0.08). Mean volume CT dose index in groups B and C (5.2 +/- 0.4 mGy and 4.9 +/- 0.3 mGy, respectively) were reduced by 23.5% and 27.9%, respectively, compared with group A (6.8 +/- 0.8 mGy) (P < 0.001). The average overall diagnostic image quality for the 3 groups was graded as good or better. The score for group A was significantly higher than that for group C (P < 0.01), no difference was seen between group A and B (P = 0.92). CONCLUSIONS: Reduction of tube voltage from 100 to 80 kVp for thoracoabdominal CT angiography significantly reduces radiation dose without compromising image quality. Reduction of contrast medium volume to 45 mL at 80 kVp resulted in lower but still diagnostically acceptable image quality.
Resumo:
RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.
Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.
Resumo:
BACKGROUND AND OBJECTIVE: This prospective, clinical pilot trial compared the Short Form 36 Health Survey (SF-36) and a nine-item quality of recovery [Quality of Recovery 9 (QoR-9)] survey to assess the 1-week outcome after liver resection and prediction of postoperative complications from baseline values before liver resection. METHODS: In 19 patients, the SF-36 was recorded preoperatively (baseline) and on postoperative day (POD) 7. SF-36 z-values (means +/- SD) for the physical component summary (PCS) and mental component summary (MCS) were calculated. QoR-9 (score 0-18) was performed at baseline, POD1, POD3, POD5 and POD7. Descriptive analysis and effect sizes (d) were calculated. RESULTS: From baseline to POD7, PCS decreased from -0.38 +/- 1.30 to -2.10 +/- 0.76 (P = 0.002, d = -1.57) and MCS from -0.71 +/- 1.50 to -1.33 +/- 1.11 (P = 0.061, d = -0.46). QoR-9 was significantly lower at POD1, POD3 and POD5 compared with baseline (P < 0.050, d < -2.0), but not at POD7 (P = 0.060, d = -1.08). Baseline PCS was significantly lower with a high effect size in patients with complications (n = 12) compared with patients without complications (n = 7) (-0.76 +/- 1.46 vs. 0.27 +/- 0.56; P = 0.044, d = -0.84) but not baseline MCS (P = 0.831, d = -0.10) or baseline QoR-9 (P = 0.384, d = -0.44). CONCLUSIONS: The SF-36 indicates that liver resection surgery has a higher impact on physical health than on mental health. QoR-9 determines the feasible time course of recovery with a 1-week return to baseline. Preoperative impaired physical health might predict postoperative complications.
Resumo:
BACKGROUND: Renal resistance index, a predictor of kidney allograft function and patient survival, seems to depend on renal and peripheral vascular compliance and resistance. Asymmetric dimethylarginine (ADMA) is an endogenous inhibitor of nitric oxide synthase and therefore influences vascular resistance. STUDY DESIGN: We investigated the relationship between renal resistance index, ADMA, and risk factors for cardiovascular diseases and kidney function in a cross-sectional study. SETTING ; PARTICIPANTS: 200 stable renal allograft recipients (133 men and 67 women with a mean age of 52.8 years). PREDICTORS: Serum ADMA concentration, pulse pressure, estimated glomerular filtration rate and recipient age. OUTCOME: Renal resistance index. MEASUREMENTS: Renal resistance index measured by color-coded duplex ultrasound, serum ADMA concentration measured by liquid chromatography-tandem mass spectrometry, estimated glomerular filtration rate (Nankivell equation), arterial stiffness measured by digital volume pulse, Framingham and other cardiovascular risk factors, and evaluation of concomitant antihypertensive and immunosuppressive medication. RESULTS: Mean serum ADMA concentration was 0.72 +/- 0.21 (+/-SD) micromol/L and mean renal resistance index was 0.71 +/- 0.07. Multiple stepwise regression analysis showed that recipient age (P < 0.001), pulse pressure (P < 0.001), diabetes (P < 0.01) and ADMA concentration (P < 0.01) were independently associated with resistance index. ADMA concentrations were correlated with estimated glomerular filtration rate (P < 0.01). LIMITATIONS: The cross-sectional nature of this study precludes cause-effect conclusions. CONCLUSIONS: In addition to established cardiovascular risk factors, ADMA appears to be a relevant determinant of renal resistance index and allograft function and deserves consideration in prospective outcome trials in renal transplantation.
Resumo:
OBJECTIVES: To investigate the contribution of a real-time PCR assay for the detection of Treponema pallidum in various biological specimens with the secondary objective of comparing its value according to HIV status. METHODS: Prospective cohort of incident syphilis cases from three Swiss hospitals (Geneva and Bern University Hospitals, Outpatient Clinic for Dermatology of Triemli, Zurich) diagnosed between January 2006 and September 2008. A case-control study was nested into the cohort. Biological specimens (blood, lesion swab or urine) were taken at diagnosis (as clinical information) and analysed by real-time PCR using the T pallidum 47 kDa gene. RESULTS: 126 specimens were collected from 74 patients with primary (n = 26), secondary (n = 40) and latent (n = 8) syphilis. Among primary syphilis, sensitivity was 80% in lesion swabs, 28% in whole blood, 55% in serum and 29% in urine, whereas among secondary syphilis, it was 20%, 36%, 47% and 44%, respectively. Among secondary syphilis, plasma and cerebrospinal fluid were also tested and provided a sensitivity of 100% and 50%, respectively. The global sensitivity of T pallidum by PCR (irrespective of the compartment tested) was 65% during primary, 53% during secondary and null during latent syphilis. No difference regarding serology or PCR results was observed among HIV-infected patients. Specificity was 100%. CONCLUSIONS: Syphilis PCR provides better sensitivity in lesion swabs from primary syphilis and displays only moderate sensitivity in blood from primary and secondary syphilis. HIV status did not modify the internal validity of PCR for the diagnosis of primary or secondary syphilis.
Resumo:
Changes in the retinal microcirculation are associated with hypertension and predict cardiovascular mortality. There are few data describing the impact of antihypertensive therapy on retinal vascular changes. This substudy of the Anglo-Scandinavian Cardiac Outcomes Trial compared the effects of an amlodipine-based regimen (373 patients) with an atenolol-based regimen (347 patients) on retinal microvascular measurements made from fundus photographs. The retinal photographs were taken at a stage in the trial when treatments were stable and blood pressure was well controlled. Amlodipine-based treatment was associated with a smaller arteriolar length:diameter ratio than atenolol-based treatment (13.32 [10.75 to 16.04] versus 14.12 [11.27 to 17.81], median [interquartile range]; P<0.01). The association remained significant after adjustment for age, sex, cholesterol, systolic and diastolic blood pressures, body mass index, smoking, and statin treatment. This effect appeared to be largely attributable to shorter retinal arteriolar segment lengths in the amlodipine-treated group and is best explained by the vasodilator effects of amlodipine causing the visible emergence of branching side vessels. Photographic assessment of the retinal vascular network may be a useful approach to evaluating microvascular structural responses in clinical trials of antihypertensive therapy.