349 resultados para Aortic Coarctation
Resumo:
Gebiet: Kardiologie Abstract: OBJECTIVES: Severe neurologiCal defiCit (ND) due to aCute aortiC disseCtion type A (AADA) was Considered a ContraindiCation for surgery beCause of poor prognosis. ReCently, more aggressive indiCation for surgery despite neurologiCal symptoms has shown aCCeptable – postoperative CliniCal results. The aim of this study was to evaluate early and mid-term outComes of patients with AADA presenting with aCute ND. – – METHODS: Data from 53 patients with new-onset ND who reCeived surgiCal repair for AADA between 2005 and 2012 at our institution were retrospeCtively reviewed. ND was defined as foCal motor or sensory defiCit, hemiplegia, paraplegia, Convulsions or Coma. NeurologiCal symptoms were evaluated preoperatively using the Glasgow Coma SCale (GCS) and modified Rankin SCale (mRS), and at disCharge as well as 3–6 months postoperatively using the mRS and National Institutes of Health Stroke SCale. Involvement of Carotid arteries was assessed in the pre- and postoperative Computed tomography. LogistiC regression analysis was performed to deteCt prediCtive faCtors for reCovery of ND. – – RESULTS: Of the 53 patients, 29 (54.7%) showed Complete reCovery from foCal ND at follow-up. NeurologiCal symptoms persisted in 24 (45.3%) patients, of whiCh 8 (33%) died without neurologiCal assessment at follow-up. Between the two groups (patients with reCovery and – those with persisting ND), there was no signifiCant differenCe regarding the duration of hypothermiC CirCulatory arrest (28 ± 14 vs 36 ± 20 min) or severely reduCed ConsCiousness (GCS <8). Multivariate analysis showed signifiCant differenCes for the preoperative mRS between the two groups (P < 0.007). A high preoperative mRS was assoCiated with persistenCe of neurologiCal symptoms (P < 0.02). CardiovasCular risk faCtors, age or involvement of supra-aortiC branChes were not prediCtive for persistenCe of ND. – – CONCLUSION: More than half of our patients reCovered Completely from ND due to AADA after surgery. Severity of CliniCal symptoms had a prediCtive value. Patients suffering from AADA and presenting with ND before surgery should not be exCluded from emergenCy surgery.
Resumo:
OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.
Resumo:
AIM To identify morphologic factors affecting aortic expansion in patients with uncomplicated type B aortic dissections. METHODS Computed tomography data of 24 patients (18 male; median age: 61 years), diagnosed with acute uncomplicated type B aortic dissections between 2002 and 2013, were retrospectively reviewed. All patients had at least two computed tomography angiography scans and six months of uneventful follow-up. Computed tomography scans were assessed by two independent readers with regard to presence and number of entry tears. Thoracic and abdominal aortic diameters were derived using image processing software. RESULTS Twenty-two of 24 patients showed aortic expansion over a median computed tomography angiographic follow-up of 33.2 months. Annual rates showed an increase of 1.7 mm for total aortic diameter, 2.1 mm for the false and a decrease of -0.4 mm for the true lumen. In three patients (12.5%), aortic diameter exceeded 60 mm during follow-up, and all three patients underwent thoracic endovascular aortic repair. Patients with a maximum aortic diameter <4 cm at baseline showed a significantly higher expansion rate compared to cases with an initial maximum aortic diameter of ≥4 cm (p=0.0471). A median of two entries (range: 1-5) was recognized per patient. Presence of more than two entry tears (n = 13) was associated with faster overall diameter expansion (mean annual rates: 2.18 mm vs. 1.16 mm; p = 0.4556), and decrease of the cross-sectional surface of the true lumen over time (annual rate for > 2 entries vs. ≤2 entries: -7.8 mm(2) vs. +37.5 mm(2); p = 0.0369). Median size of entry tears was 12 mm (range: 2-53 mm). CONCLUSIONS The results presented herein suggest that uncomplicated type B aortic dissection patients with more than two entry tears and/or an initial maximum aortic diameter of<4 cm are at risk for aortic dilatation and, therefore, may require stricter follow-up including the possible need for early intervention.
Resumo:
PURPOSE The purpose of this study was to identify morphologic factors affecting type I endoleak formation and bird-beak configuration after thoracic endovascular aortic repair (TEVAR). METHODS Computed tomography (CT) data of 57 patients (40 males; median age, 66 years) undergoing TEVAR for thoracic aortic aneurysm (34 TAA, 19 TAAA) or penetrating aortic ulcer (n = 4) between 2001 and 2010 were retrospectively reviewed. In 28 patients, the Gore TAG® stent-graft was used, followed by the Medtronic Valiant® in 16 cases, the Medtronic Talent® in 8, and the Cook Zenith® in 5 cases. Proximal landing zone (PLZ) was in zone 1 in 13, zone 2 in 13, zone 3 in 23, and zone 4 in 8 patients. In 14 patients (25%), the procedure was urgent or emergent. In each case, pre- and postoperative CT angiography was analyzed using a dedicated image processing workstation and complimentary in-house developed software based on a 3D cylindrical intensity model to calculate aortic arch angulation and conicity of the landing zones (LZ). RESULTS Primary type Ia endoleak rate was 12% (7/57) and subsequent re-intervention rate was 86% (6/7). Left subclavian artery (LSA) coverage (p = 0.036) and conicity of the PLZ (5.9 vs. 2.6 mm; p = 0.016) were significantly associated with an increased type Ia endoleak rate. Bird-beak configuration was observed in 16 patients (28%) and was associated with a smaller radius of the aortic arch curvature (42 vs. 65 mm; p = 0.049). Type Ia endoleak was not associated with a bird-beak configuration (p = 0.388). Primary type Ib endoleak rate was 7% (4/57) and subsequent re-intervention rate was 100%. Conicity of the distal LZ was associated with an increased type Ib endoleak rate (8.3 vs. 2.6 mm; p = 0.038). CONCLUSIONS CT-based 3D aortic morphometry helps to identify risk factors of type I endoleak formation and bird-beak configuration during TEVAR. These factors were LSA coverage and conicity within the landing zones for type I endoleak formation and steep aortic angulation for bird-beak configuration.
Resumo:
The aim of this study was to evaluate the diagnostic criteria and to identify the radiological signs (derived from known radiological signs) for the detection of aortic dissections using postmortem computed tomography (PMCT). Thirty-three aortic dissection cases were retrospectively evaluated; all underwent PMCT and autopsy. The images were initially evaluated independently by two readers and were subsequently evaluated in consensus. Known radiological signs, such as dislocated calcification and an intimomedial flap, were identified. The prevalence of the double sedimentation level in the true and false lumen of the dissected aorta was assessed and defined as a postmortem characteristic sign of aortic dissection. Dislocated calcification was detected in 85% of the cases with aortic calcification; whereas in 54% of the non-calcified aortas, the intimomedial flap could also be recognized. Double sedimentation was identified in 16/33 of the cases. Overall, in 76% (25/33) of the study cases, the described signs, which are indicative for aortic dissection, could be identified. In this study, three diagnostic criteria of aortic dissection were identified using non-enhanced PMCT images of autopsy-confirmed dissection cases.
Resumo:
Data concerning the link between severity of abdominal aortic calcification (AAC) and fracture risk in postmenopausal women are discordant. This association may vary by skeletal site and duration of follow-up. Our aim was to assess the association between the AAC severity and fracture risk in older women over the short- and long term. This is a case-cohort study nested in a large multicenter prospective cohort study. The association between AAC and fracture was assessed using Odds Ratios (OR) and 95% confidence intervals (95%CI) for vertebral fractures and using Hazard Risks (HR) and 95%CI for non-vertebral and hip fractures. AAC severity was evaluated from lateral spine radiographs using Kauppila's semiquantitative score. Severe AAC (AAC score 5+) was associated with higher risk of vertebral fracture during 4 years of follow-up, after adjustment for confounders (age, BMI, walking, smoking, hip bone mineral density, prevalent vertebral fracture, systolic blood pressure, hormone replacement therapy) (OR=2.31, 95%CI: 1.24-4.30, p<0.01). In a similar model, severe AAC was associated with an increase in the hip fracture risk (HR=2.88, 95%CI: 1.00-8.36, p=0.05). AAC was not associated with the risk of any non-vertebral fracture. AAC was not associated with the fracture risk after 15 years of follow-up. In elderly women, severe AAC is associated with higher short-term risk of vertebral and hip fractures, but not with the long-term risk of these fractures. There is no association between AAC and risk of non-vertebral-non-hip fracture in older women. Our findings lend further support to the hypothesis that AAC and skeletal fragility are related.
Resumo:
BACKGROUND Biomarkers of myocardial injury increase frequently during transcatheter aortic valve implantation (TAVI). The impact of postprocedural cardiac troponin (cTn) elevation on short-term outcomes remains controversial, and the association with long-term prognosis is unknown. METHODS AND RESULTS We evaluated 577 consecutive patients with severe aortic stenosis treated with TAVI between 2007 and 2012. Myocardial injury, defined according to the Valve Academic Research Consortium (VARC)-2 as post-TAVI cardiac troponin T (cTnT) >15× the upper limit of normal, occurred in 338 patients (58.1%). In multivariate analyses, myocardial injury was associated with higher risk of all-cause mortality at 30 days (adjusted hazard ratio [HR], 8.77; 95% CI, 2.07-37.12; P=0.003) and remained a significant predictor at 2 years (adjusted HR, 1.98; 95% CI, 1.36-2.88; P<0.001). Higher cTnT cutoffs did not add incremental predictive value compared with the VARC-2-defined cutoff. Whereas myocardial injury occurred more frequently in patients with versus without coronary artery disease (CAD), the relative impact of cTnT elevation on 2-year mortality did not differ between patients without CAD (adjusted HR, 2.59; 95% CI, 1.27-5.26; P=0.009) and those with CAD (adjusted HR, 1.71; 95% CI, 1.10-2.65; P=0.018; P for interaction=0.24). Mortality rates at 2 years were lowest in patients without CAD and no myocardial injury (11.6%) and highest in patients with complex CAD (SYNTAX score >22) and myocardial injury (41.1%). CONCLUSIONS VARC-2-defined cTnT elevation emerged as a strong, independent predictor of 30-day mortality and remained a modest, but significant, predictor throughout 2 years post-TAVI. The prognostic value of cTnT elevation was modified by the presence and complexity of underlying CAD with highest mortality risk observed in patients combining SYNTAX score >22 and evidence of myocardial injury.
Resumo:
OBJECTIVE Type A aortic dissection is a life-threatening disease requiring immediate surgical treatment. With emerging catheter-based technologies, endovascular stent-graft implantation to treat aneurysms and dissections has become a standardized procedure. However, endovascular treatment of the ascending aorta remains challenging. Thus we designed an ascending aortic dissection model to allow simulation of endovascular treatment. METHODS Five formalin-fixed human aortas were prepared. The ascending aorta was opened semicircularly in the middle portion and the medial layer was separated from the intima. The intimal tube was readapted using running monofilament sutures. The preparations were assessed by 128-slice computed tomography. A bare-metal stent was implanted for thoracic endovascular aortic repair in 4 of the aortic dissection models. RESULTS Separation of the intimal and medial layer of the aorta was considered to be sufficient because computed tomography showed a clear image of the dissection membrane in each aorta. The dissection was located 3.9 ± 1.4 cm proximally from the aortic annulus, with a length of 4.6 ± 0.9 cm. Before stent implantation, the mean distance from the intimal flap to the aortic wall was measured as 0.63 ± 0.163 cm in the ascending aorta. After stent implantation, this distance decreased to 0.26 ± 0.12 cm. CONCLUSION This model of aortic dissection of the ascending human aorta was reproducible with a comparable pathological and morphological appearance. The technique and model can be used to evaluate new stent-graft technologies to treat type A dissection and facilitate training for surgeons.
Resumo:
OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.
Resumo:
To compare intraoperative cerebral microembolic load between minimally invasive extracorporeal circulation (MiECC) and conventional extracorporeal circulation (CECC) during isolated surgical aortic valve replacement (SAVR), we conducted a randomized trial in patients undergoing primary elective SAVR at a tertiary referral hospital. The primary outcome was the procedural phase-related rate of high-intensity transient signals (HITS) on transcranial Doppler ultrasound. HITS rate was used as a surrogate of cerebral microembolism in pre-defined procedural phases in SAVR using MiECC or CECC with (+F) or without (-F) an oxygenator with integrated arterial filter. Forty-eight patients were randomized in a 1:1 ratio to MiECC or CECC. Due to intraprocedural Doppler signal loss (n = 3), 45 patients were included in final analysis. MiECC perfusion regimen showed a significantly increased HITS rate compared to CECC (by a factor of 1.75; 95% confidence interval, 1.19-2.56). This was due to different HITS rates in procedural phases from aortic cross-clamping until declamping [phase 4] (P = 0.01), and from aortic declamping until stop of extracorporeal perfusion [phase 5] (P = 0.05). Post hoc analysis revealed that MiECC-F generated a higher HITS rate than CECC+F (P = 0.005), CECC-F (P = 0.05) in phase 4, and CECC-F (P = 0.03) in phase 5, respectively. In open-heart surgery, MiECC is not superior to CECC with regard to gaseous cerebral microembolism. When using MiECC for SAVR, the use of oxygenators with integrated arterial line filter appears highly advisable. Only with this precaution, MiECC confers a cerebral microembolic load comparable to CECC during this type of open heart surgery.