396 resultados para PERCUTANEOUS VERTEBROPLASTY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: As part of the EAPCI Young Initiative, the European Association of Percutaneous Cardiovascular Interventions (EAPCI) conducted a survey to address the educational needs of young interventional cardiologists. Methods and results: A questionnaire was distributed to all individuals registered in the ESC database aged <36 years with an interest in interventional cardiology. Nearly two-thirds of participants (60%) indicated that they had difficulty in finding a fellowship training position. The desire for a fellow's course at European level was expressed by 95%, while 94% were in favour of developing a network of young interventional cardiologists in Europe. More than three-quarters of respondents (79%) said they had had difficulty in obtaining funding to attend EuroPCR. Multiple difficulties were identified in setting up a research programme, two of the more frequent being problematic access to research networks and the difficulties of finding a mentor. Career orientation was identified as another issue, with more than half of respondents (59%) declaring they followed career options by chance. Conclusions: The survey underlines the need to fill a gap in order to address the needs of young interventional cardiologists. It may serve as a starting point for developing educational initiatives targeted at young interventional cardiologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a widely accepted alternative to surgical aortic valve replacement (SAVR) among non-operable patients or selected high-risk patients with degenerative, severe aortic stenosis. TAVI is considered less invasive when compared with SAVR; however, there remain significant differences between different TAVI access routes. The transfemoral approach is considered the least invasive access route, and can be performed as a fully percutaneous procedure in a spontaneously breathing patient under local anaesthesia and mild sedation only. Moreover, transfemoral TAVI patients are typically transferred to coronary care rather than to an intensive care unit after the procedure, and benefit from early ambulation and a reduction in overall length of hospital stay. Considering these patient-specific and health-economic advantages, several TAVI centres follow the least invasive strategy for their patients and have implemented the transfemoral access route as the default access in their institutions. This article provides an overview on the prerequisites for a successful transfemoral TAVI procedure, describes the procedural advantages compared to alternative access routes, and highlights differences in clinical outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF and ventricular lesion formation. We studied the impact of CF on lesion formation using an ovine model both endocardially and epicardially. METHODS AND RESULTS Twenty sheep received 160 epicardial and 160 endocardial ventricular radiofrequency applications using either a 3.5-mm irrigated-tip catheter (Thermocool, Biosense-Webster, n=160) or a 3.5 irrigated-tip catheter with CF assessment (Tacticath, Endosense, n=160), via percutaneous access. Power was delivered at 30 watts for 60 seconds, when either catheter/tissue contact was felt to be good or when CF>10 g with Tacticath. After completion of all lesions, acute dimensions were taken at pathology. Identifiable lesion formation from radiofrequency application was improved with the aid of CF information, from 78% to 98% on the endocardium (P<0.001) and from 90% to 100% on the epicardium (P=0.02). The mean total force was greater on the endocardium (39±18 g versus 21±14 g for the epicardium; P<0.001) mainly because of axial force. Despite the force-time integral being greater endocardially, epicardial lesions were larger (231±182 mm(3) versus 209±131 mm(3); P=0.02) probably because of the absence of the heat sink effect of the circulating blood and covered a greater area (41±27 mm(2) versus 29±17 mm(2); P=0.03) because of catheter orientation. CONCLUSIONS In the absence of CF feedback, 22% of endocardial radiofrequency applications that are thought to have good contact did not result in lesion formation. Epicardial ablation is associated with larger lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to determine the incidence of atrial flutter and other arrhythmia recurrences (other than atrial fibrillation [AF]) during long-term follow-up after left atrial substrate modification by percutaneous radiofrequency (RF) ablation of AF. BACKGROUND RF ablation is an effective treatment for patients with AF. However, late recurrent arrhythmias may complicate the patient's course. METHODS One hundred fifty consecutive patients with paroxysmal or persistent AF were included in this prospective study. The incidence of arrhythmia recurrences after AF ablation was analyzed during long-term follow-up using repetitive 7-day ECG recording. RESULTS In 28 of 150 patients (18.7%), stable regular arrhythmias other than AF were detected during follow-up. Left atrial flutter observed in 10 patients (6.7%) was treated by recompletion of the ablation lines in all 10 patients. Left atrial flutter was associated with recurrence of AF in all 10 patients. Nine of 10 patients (90%) were free from atrial flutter and 6 of 10 patients were free from AF after the second intervention. Typical right atrial flutter occurred in 10 patients (6.7%) and was treated successfully by percutaneous RF ablation without recurrence in all patients. Additionally, atrial flutter was documented during follow-up in 7 patients (4.7%); however, invasive electrophysiologic evaluation was not performed due to various reasons. CONCLUSIONS Left atrial flutter is a relevant complication after RF catheter ablation of AF and was always associated with AF recurrence in our study population. Prevention of left atrial flutter can be achieved by induction of ablation lines as continuous and transmural as possible. However, left atrial flutter that does occur late after ablation is amenable to interventional treatment with good prospects of success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Intraoperative radiofrequency (RF) ablation is an effective treatment of atrial fibrillation (AF). However, secondary arrhythmias late after ablation may complicate the patient's course. We report on the incidence, mechanisms, and treatment of gap-related atrial flutter and other secondary arrhythmias during long-term follow-up. METHODS AND RESULTS In 129 patients who underwent intraoperative RF ablation with placement of left atrial linear lesions using minimally invasive surgical techniques, secondary arrhythmias were analyzed during long-term follow-up (20 +/- 6 months). Transient atrial arrhythmias during the first 3 postoperative months were excluded. In 8 (6.2%) of 129 patients, sustained stable secondary arrhythmias were documented. Left atrial, gap-related atrial flutter was observed in 4 patients (3.1%). The flutter was treated by percutaneous RF ablation in 3 patients (2.3%) and with drugs in 1 patient (0.8%). In 2 patients (1.6%), right atrial isthmus-dependent atrial flutter occurred and was treated successfully by percutaneous RF ablation. In 2 patients (1.6%), ectopic right atrial tachycardias occurred and were treated with percutaneous RF ablation. CONCLUSION Late after intraoperative RF ablation of atrial fibrillation, three types of stable secondary arrhythmias were observed in 6% of patients: left atrial gap-related atrial flutter, right atrial isthmus-dependent atrial flutter, and ectopic atrial tachycardia. Gaps after intraoperative RF ablation due to noncontinuous or nontransmural linear lesions may lead to stable left atrial macroreentrant tachycardias, requiring new interventional therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Evaluation of health-related quality of life (HRQL) is important in improving the quality of patient care. The aim of this study was to determine the psychometric properties of the HeartQoL in patients with ischemic heart disease (IHD), specifically angina, myocardial infarction (MI), or ischemic heart failure. Methods: Data for the interim validation of the HeartQoL questionnaire were collected in (a) a cross-sectional survey and (b) a prospective substudy of patients undergoing either a percutaneous coronary intervention (PCI) or referred to cardiac rehabilitation (CR) and were then analyzed to determine the reliability, validity, and responsiveness of the HeartQoL questionnaire. Results: We enrolled 6384 patients (angina, n = 2111, 33.1%; MI, n = 2351, 36.8%; heart failure, n = 1922, 30.1%) across 22 countries speaking 15 languages in the cross-sectional study and 730 patients with IHD in the prospective substudy. The HeartQoL questionnaire comprises 14-items with physical and emotional subscales and a global score (range 0–3 (poor to better HRQL). Cronbach’s α was consistently ≥0.80; convergent validity correlations between similar HeartQoL and SF-36 subscales were significant (r ≥ 0.60, p < 0.001); discriminative validity was confirmed with predictor variables: health transition, anxiety, depression, and functional status. HeartQoL score changes following either PCI or CR were significant (p < 0.001) with effect sizes ranging from 0.37–0.64. Conclusion: The HeartQoL questionnaire is reliable, valid, and responsive to change allowing clinicians and researchers to (a) assess baseline HRQL, (b) make between-diagnosis comparisons of HRQL, and (c) evaluate change in HRQL in patients with angina, MI, or heart failure with a single IHD-specific HRQL instrument.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In Chopart-level amputations the heel often deviates into equinus and varus when, due to the lack of healthy anterior soft tissue, rebalancing tendon transfers to the talar head are not possible. Consequently, anterior and lateral wound dehiscence and ulceration may occur requiring higher-level amputation to achieve wound closure, with considerable loss of function for the patients. METHODS Twenty-four consecutive patients (15 diabetes, 6 trauma, and 3 tumor) had Chopart's amputation and simultaneous or delayed additional ankle dorsiflexion arthrodesis to allow for tension-free wound closure or soft tissue reconstruction, or to treat secondary recurrent ulcerations. Percutaneous Achilles tendon lengthening and subtalar arthrodesis were added as needed. Wound healing problems, time to fusion and full weight-bearing in the prosthesis, complications in the prosthesis, and the ambulatory status were assessed. Satisfaction and function were evaluated by the AmpuPro score and the validated Prosthesis Evaluation Questionnaire scale. RESULTS Five patients had successful soft tissue healing and fusions but died of their underlying disease 2 to 46 months after the operation. Two diabetic patients required a transtibial amputation. The other 17 patients were followed for 27 months (range, 13-63). The average age of the 4 women and 13 men was 53.9 years (range, 16-87). Postoperative complications included minor wound healing problems in 8 patients, wound breakdown requiring revision in 4, phantom pain in 3, residual equinus in 1, and adjacent scar carcinoma in 1 patient. The time to full weight-bearing in the prosthesis ranged from 6 to 24 weeks (mean 10). The mean AmpuPro score was 107 points (of 120), and the mean Prosthesis Evaluation Questionnaire scale was 147 points (of 200). No complications occurred with the prosthesis. Twelve patients lost 1 to 2 mobility classes (mean 0.9). The arthrodeses all healed within 2.5 months (range, 1.5 to 5 months). CONCLUSION Adding an ankle arthrodesis to a Chopart's amputation either immediately or in a delayed fashion to treat anterior soft tissue complications was a successful salvage in most patients at this amputation level. It enabled the patients to preserve the advantages of a full-length limb with terminal weight-bearing. LEVEL OF EVIDENCE Level IV, retrospective case series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant’s location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map (n = 10) with conventional surgery without assistance (n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and OPEN ACCESS Materials 2013, 6 5292 suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient’s safety during BAP surgery in the temporal bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose We compared the long-term results of minimally invasive endourological intervention and open surgical revision in patients with a nonmalignant ureteroileal stricture. Materials and Methods We retrospectively evaluated the records of 74 patients (85 renal units) treated for unilateral or bilateral nonmalignant ureteroileal strictures. Overall, 96 endourological and 35 open surgical procedures were performed. Balloon dilatation and Acucise® or Ho:YAG laser endoureterotomy were used as minimally invasive endourological interventions. Open surgical revision with stricture resection and open ureteroileal end-to-side-reanastomosis was the alternate therapy. Treatment success was defined as radiological normalization or improvement of upper urinary tract morphology combined with absent flank pain, infection, ureteral stents or percutaneous nephrostomies. Results Median followup was 29 months (range 2 to 177). The overall success rate was 26% (25 of 96 cases) for endourological intervention vs 91% (32 of 35) for open surgical revision (p <0.001). Subgroup analysis showed a significant difference in the success rate of minimally invasive endourological interventions vs open surgical revision for strictures greater than 1 cm (3 of 52 cases or 6% vs 19 of 22 or 86%, p <0.001). The success rate of endourological and open surgical procedures for strictures 1 cm or less was 50% (22 of 44 cases) and 100% (13 of 13), respectively. After adjusting for multiple preoperative stricture characteristics, only stricture length was strongly and inversely associated with a successful outcome (p <0.001). Conclusions Open surgical revision produces better results than minimally invasive endourological intervention for ureteroileal strictures, particularly those greater than 1 cm. The success rate of endourological intervention is acceptable only for ureteroileal strictures 1 cm or less. Therefore, ureteroileal strictures greater than 1 cm should be primarily managed by open surgical revision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 34-year-old male patient was referred for primary percutaneous coronary intervention for ST-segment elevation myocardial infarction with cardiogenic shock and was found to have embolic left coronary artery occlusion and subsegmental pulmonary artery emboli as a consequence of venous thrombosis to trauma to the thigh in the presence of a patent foramen ovale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporary transcoronary unipolar pacing is a validated simple, effective, and safe alternative to temporary transvenous pacing of the right ventricle for the treatment of relevant bradyarrhythmias complicating percutaneous coronary intervention. We describe the use of rapid transcoronary pacing to aid precise placement of a stent in the left main coronary artery bifurcation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Accurate needle placement is crucial for the success of percutaneous radiological needle interventions. We compared three guiding methods using an optical-based navigation system: freehand, using a stereotactic aiming device and active depth control, and using a stereotactic aiming device and passive depth control. METHODS For each method, 25 punctures were performed on a non-rigid phantom. Five 1 mm metal screws were used as targets. Time requirements were recorded, and target positioning errors (TPE) were measured on control scans as the distance between needle tip and target. RESULTS Time requirements were reduced using the aiming device and passive depth control. The Euclidian TPE was similar for each method (4.6 ± 1.2-4.9 ± 1.7 mm). However, the lateral component was significantly lower when an aiming device was used (2.3 ± 1.3-2.8 ± 1.6 mm with an aiming device vs 4.2 ± 2.0 mm without). DISCUSSION Using an aiming device may increase the lateral accuracy of navigated needle insertion.