380 resultados para Aortic rupture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The cause precipitating intracranial aneurysm rupture remains unknown in many cases. It has been observed that aneurysm ruptures are clustered in time, but the trigger mechanism remains obscure. Because solar activity has been associated with cardiovascular mortality and morbidity, we decided to study its association to aneurysm rupture in the Swiss population. METHODS Patient data were extracted from the Swiss SOS database, at time of analysis covering 918 consecutive patients with angiography-proven aneurysmal subarachnoid hemorrhage treated at 7 Swiss neurovascular centers between January 1, 2009, and December 31, 2011. The daily rupture frequency (RF) was correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux [F10.7 index], solar proton flux, solar flare occurrence, planetary K-index/planetary A-index, Space Environment Services Center [SESC] sunspot number and sunspot area) using Poisson regression analysis. RESULTS During the period of interest, there were 517 days without recorded aneurysm rupture. There were 398, 139, 27, 12, 1, and 1 days with 1, 2, 3, 4, 5, and 6 ruptures per day. Poisson regression analysis demonstrated a significant correlation of F10.7 index and RF (incidence rate ratio [IRR] = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719-1.008894; P < 0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. A likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95% CI 1.001864-1.004965; P < 0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95% CI 1.000249-1.000589; P < 0.001) emerged. All other variables analyzed showed no significant correlation with RF. CONCLUSIONS We found greater radioflux, SESC sunspot number, and sunspot area to be associated with an increased count of aneurysm rupture. The clinical meaningfulness of this statistical association must be interpreted carefully and future studies are warranted to rule out a type-1 error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: A number of intrinsic and extrinsic risk factors for the rupture of intracranial aneurysms have been identified. Still, the cause precipitating aneurysm rupture remains unknown in many cases. In addition, it has been observed that aneurysm ruptures are clustered in time but the trigger mechanism remains obscure. As solar activity has been associated with cardiovascular mortality and morbidity we decided to study ist association to aneurysm rupture in the Swiss population. Method: Patient data was extracted from the Swiss SOS database, at time of analysis covering 918 patients with angiography-proven aSAH treated at seven Swiss neurovascular centers between 01/01/2009 – 12/31/2011. The number of aneurysm rupture per day, week, month (Daily/Weekly/Monthly Rupture Frequency = RF) was measured and correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux (F10.7 index), solar proton flux, solar flare occurrence, planetary K-index/planetary A-index) using Poisson regression analysis. Results: Of a consecutive series of 918 cases of SAH, precise determination of the date of symptom onset was possible in 816 (88.9%). During the period of interest there were 517 days without recorded aneurysm rupture. There were 398, 139, 27 and 12 days with 1, 2, 3, and 4 ruptures per day. Five or 6 ruptures were only noted on a single day each. Poisson regression analysis demonstrated a significant correlation of F10.7 index and aneurysm rupture (incidence rate ratio (IRR) = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719 – 1.008894; p<0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. As the F10.7 index is known to correlate well with the Space Environment Services Center (SESC) sunspot number, we performed additional analyses on SESC sunspot number and sunspot area. Here, a likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95%CI 1.001864 – 1.004965; p<0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95%CI 1.000249 – 1.000589; p<0.001) emerged. All other variables analyzed showed no correlation with RF. Conclusions: Using valid methods, we found higher radioflux, sunspot number and sunspot area to be associated with an increased count of aneurysm rupture. Since we were using rupture frequencies rather than incidences and because we cannot explain the physiological basis of this statistical association, the clinical meaningfulness of this statistical association must be interpreted carefully. Future studies are warranted to rule out a type-1 error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To develop a method for computing and visualizing pressure differences derived from time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and to compare pressure difference maps of patients with unrepaired and repaired aortic coarctation to young healthy volunteers. METHODS 4D flow MRI data of four patients with aortic coarctation either before or after repair (mean age 17 years, age range 3-28, one female, three males) and four young healthy volunteers without history of cardiovascular disease (mean age 24 years, age range 20-27, one female, three males) was acquired using a 1.5-T clinical MR scanner. Image analysis was performed with in-house developed image processing software. Relative pressures were computed based on the Navier-Stokes equation. RESULTS A standardized method for intuitive visualization of pressure difference maps was developed and successfully applied to all included patients and volunteers. Young healthy volunteers exhibited smooth and regular distribution of relative pressures in the thoracic aorta at mid systole with very similar distribution in all analyzed volunteers. Patients demonstrated disturbed pressures compared to volunteers. Changes included a pressure drop at the aortic isthmus in all patients, increased relative pressures in the aortic arch in patients with residual narrowing after repair, and increased relative pressures in the descending aorta in a patient after patch aortoplasty. CONCLUSIONS Pressure difference maps derived from 4D flow MRI can depict alterations of spatial pressure distribution in patients with repaired and unrepaired aortic coarctation. The technique might allow identifying pathophysiological conditions underlying complications after aortic coarctation repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies. Description A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm. Evaluation This model was very helpful for the preoperative decision making and planning of the frozen elephant trunk procedure owing to the exact and lifelike illustration of the native aortic arch. Conclusions Three-dimensional models are helpful in preoperative planning and postoperative evaluation of frozen elephant trunk procedures in patients with complex aortic anatomy.