349 resultados para Aortic Coarctation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Up to 1 in 6 patients undergoing transcatheter aortic valve implantation (TAVI) present with low-ejection fraction, low-gradient (LEF-LG) severe aortic stenosis and concomitant relevant mitral regurgitation (MR) is present in 30% to 55% of these patients. The effect of MR on clinical outcomes of LEF-LG patients undergoing TAVI is unknown. METHODS AND RESULTS Of 606 consecutive patients undergoing TAVI, 113 (18.7%) patients with LEF-LG severe aortic stenosis (mean gradient ≤40 mm Hg, aortic valve area <1.0 cm(2), left ventricular ejection fraction <50%) were analyzed. LEF-LG patients were dichotomized into ≤mild MR (n=52) and ≥moderate MR (n=61). Primary end point was all-cause mortality at 1 year. No differences in mortality were observed at 30 days (P=0.76). At 1 year, LEF-LG patients with ≥moderate MR had an adjusted 3-fold higher rate of all-cause mortality (11.5% versus 38.1%; adjusted hazard ratio, 3.27 [95% confidence interval, 1.31-8.15]; P=0.011), as compared with LEF-LG patients with ≤mild MR. Mortality was mainly driven by cardiac death (adjusted hazard ratio, 4.62; P=0.005). As compared with LEF-LG patients with ≥moderate MR assigned to medical therapy, LEF-LG patients with ≥moderate MR undergoing TAVI had significantly lower all-cause mortality (hazard ratio, 0.38; 95% confidence interval, 0.019-0.75) at 1 year. CONCLUSIONS Moderate or severe MR is a strong independent predictor of late mortality in LEF-LG patients undergoing TAVI. However, LEF-LG patients assigned to medical therapy have a dismal prognosis independent of MR severity suggesting that TAVI should not be withheld from symptomatic patients with LEF-LG severe aortic stenosis even in the presence of moderate or severe MR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.