26 resultados para vascular lesions


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Data on female patients with atherosclerotic peripheral arterial disease (PAD) are scarce, and limited primarily to the elderly population with multilevel disease. In this longitudinal observational study we compare female patients below 60 years of age with isolated lesions at the aortic bifurcation or focal superficial femoral artery disease. PATIENTS AND METHODS: Analysis is based on consecutive series of 43 female patients with PAD limited to the aortoiliac bifurcation (n = 28, group I) or an isolated femoral segment at the adductor channel (n = 15, group II) seen in a tertiary referral center between 1998 and 2000. The first assessment provided baseline data, with follow up data obtained at this study. Traditional risk factors, carotid artery disease and clinical outcome (mortality, cardiovascular events, vascular re-intervention rate, PAD progression) were evaluated over an interval of 5 (2 to 8) years. RESULTS: Female patients with aortic disease [group I] were younger (51.8 +/- 7.7 vs. 56.7 +/- 7.6 years in group II; p = 0.048), presented a more masculine phenotype, and smoked significantly more often (82% vs. 40%; p = 0.007). Arterial hypertension and diabetes mellitus were more common in group II, though it missed statistical significance (p = 0.068 and p = 0.085). Cardiovascular and limb outcome were comparable in both groups of female patients, while carotid artery disease was more severe in group I (i.e., carotid plaques in 71 vs. 53%). CONCLUSION: Our data support previous findings that cigarette smoking is a stronger risk factor for aortic disease as compared to femoral disease in younger female patients, with the strongest effect of smoking on a localized region of the aortic bifurcation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vascular birthmarks can be classified into hemangioma and vascular malformations. Hemangioma are frequent tumours of early infancy demonstrating endothelial hyperplasia, a history of rapid neonatal growth and slow involution during later childhood. Treatment of hemangioma is dependent of stage and type of the lesion. Given the current availability of drugs, lasers, and other techniques to treat hemangioma safely, philosophy of "benign neglect" should not be considered anymore. Vascular malformations show a normal endothelial turnover, being present at birth and growing commensurately with the child. Exact diagnosis by employing modern diagnostic means,which are able to differentiate low-flow from high flow lesions is important for further therapeutic management. Beside conservative treatment strategies, use of laser, sclerotherapy, interventional embolization and surgical treatment are possible management options. Patients should receive multidisciplinary care in qualified vascular centres.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous work has shown that c-Myc is required for adequate vasculogenesis and angiogenesis. To further investigate the contribution of Myc to these processes, we conditionally expressed c-Myc in embryonic endothelial cells using a tetracycline-regulated system. Endothelial Myc overexpression resulted in severe defects in the embryonic vascular system. Myc-expressing embryos undergo widespread edema formation and multiple hemorrhagic lesions. They die between embryonic days 14.5 and 17.5. The changes in vascular permeability are not caused by deficiencies in vascular basement membrane composition or pericyte coverage. However, the overall turnover of endothelial cells is elevated as is revealed by increased levels of both proliferation and apoptosis. Whole-mount immunohistochemical analysis revealed alterations in the architecture of capillary networks. The dermal vasculature of Myc-expressing embryos is characterized by a reduction in vessel branching, which occurs despite upregulation of the proangiogenic factors vascular endothelial growth factor-A and angiopoietin-2. Thus, the net outcome of an excess of vascular endothelial growth factor-A and angiopoietin-2 in the face of an elevated cellular turnover appears to be a defect in vascular integrity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clostridium perfringens type C-induced enteritis necroticans is a rare but often fatal disease in humans. A consistent histopathological finding is an acute, deep necrosis of the small intestinal mucosa associated with acute vascular necrosis and massive haemorrhage in the lamina propria and submucosa. Retrospective immunohistochemical investigations of tissues from a diabetic adult who died of enteritis necroticans revealed endothelial localization of C. perfringens beta-toxin in small intestinal lesions. Our results indicate that vascular necrosis might be induced by a direct interaction between C. perfringens beta-toxin and endothelial cells and that targeted disruption of endothelial cells plays a role in the pathogenesis of enteritis necroticans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to assess the vascular response of overlapping Absorb stents compared with overlapping newer-generation everolimus-eluting metallic platform stents (Xience V [XV]) in a porcine coronary artery model. BACKGROUND: The everolimus-eluting bioresorbable vascular scaffold (Absorb) is a novel approach to treating coronary lesions. A persistent inflammatory response, fibrin deposition, and delayed endothelialization have been reported with overlapping first-generation drug-eluting stents. METHODS: Forty-one overlapping Absorb and overlapping Xience V (XV) devices (3.0 × 12 mm) were implanted in the main coronary arteries of 17 nonatherosclerotic pigs with 10% overstretch. Implanted coronary arteries were evaluated by optical coherence tomography (OCT) at 28 days (Absorb n = 11, XV n = 7) and 90 days (Absorb n = 11, XV n = 8), with immediate histological evaluation following euthanasia at the same time points. One animal from each time point was evaluated with scanning electron microscopy alone. A total of 1,407 cross sections were analyzed by OCT and 148 cross sections analyzed histologically. RESULTS: At 28 days in the overlap, OCT analyses indicated 80.1% of Absorb struts and 99.4% of XV struts to be covered (p < 0.0001), corresponding to histological observations of struts with cellular coverage of 75.4% and 99.6%, respectively (p < 0.001). Uncovered struts were almost exclusively related to the presence of "stacked" Absorb struts, that is, with a direct overlay configuration. At 90 days, overlapping Absorb and overlapping XV struts demonstrated >99% strut coverage by OCT and histology, with no evidence of a significant inflammatory process, and comparable % volume obstructions. CONCLUSIONS: In porcine coronary arteries implanted with overlapping Absorb or overlapping XV struts, strut coverage is delayed at 28 days in overlapping Absorb, dependent on the overlay configuration of the thicker Absorb struts. At 90 days, both overlapping Absorb and overlapping XV have comparable strut coverage. The implications of increased strut thickness may have important clinical and design considerations for bioresorbable platforms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Diagnostic tools to show emboli reliably and protection techniques against embolization when employing stent retrievers are necessary to improve endovascular stroke therapy. The aim of the present study was to investigate iatrogenic emboli using susceptibility-weighted imaging (SWI) in an open series of patients who had been treated with stent retriever thrombectomy using emboli protection techniques. METHODS Patients with anterior circulation stroke examined with MRI before and after stent retriever thrombectomy were assessed for iatrogenic embolic events. Thrombectomy was performed in flow arrest and under aspiration using a balloon-mounted guiding catheter, a distal access catheter, or both. RESULTS In 13 of 57 patients (22.8 %) post-interventional SWI sequences detected 16 microemboli. Three of them were associated with small ischemic lesions on diffusion-weighted imaging (DWI). None of the microemboli were located in a new vascular territory, none showed clinical signs, and all 13 patients have been rated as Thrombolysis in Cerebral Infarction (TICI) 2b (n = 3) or 3 (n = 10). Retrospective reevaluation of the digital subtraction angiography (DSA) detected discrete flow stagnation nearby the iatrogenic microemboli in four patients with a positive persistent collateral sign in one. CONCLUSION Our study demonstrates two things: First, SWI seems to be more sensitive to detect emboli than DWI and DSA and, second, proximal or distal protected stent retriever thrombectomy seems to prevent iatrogenic embolization into new vascular territories during retraction of the thrombus, but not downstream during mobilization of the thrombus. Both techniques should be investigated and refined further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with delayed arterial healing and impaired stent-related outcomes. The purpose of the present study is to compare directly the arterial healing response, angiographic efficacy and clinical outcomes between the Absorb BVS and metallic EES. METHODS AND RESULTS A total of 191 patients with acute STEMI were randomly allocated to treatment with the Absorb BVS or a metallic EES 1:1. The primary endpoint is the neointimal healing (NIH) score, which is calculated based on a score taking into consideration the presence of uncovered and malapposed stent struts, intraluminal filling defects and excessive neointimal proliferation, as detected by optical frequency domain imaging (OFDI) six months after the index procedure. The study will provide 90% power to show non-inferiority of the Absorb BVS compared with the EES. CONCLUSIONS This will be the first randomised study investigating the arterial healing response following implantation of the Absorb BVS compared with the EES. The healing response assessed by a novel NIH score in conjunction with results on angiographic efficacy parameters and device-oriented events will elucidate disease-specific applications of bioresorbable scaffolds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To report acute/subacute vision loss and paracentral scotomata in patients with idiopathic multifocal choroiditis/punctate inner choroidopathy due to large zones of acute photoreceptor attenuation surrounding the chorioretinal lesions. METHODS Multimodal imaging case series. RESULTS Six women and 2 men were included (mean age, 31.5 ± 5.8 years). Vision ranged from 20/20-1 to hand motion (mean, 20/364). Spectral domain optical coherence tomography demonstrated extensive attenuation of the external limiting membrane, ellipsoid and interdigitation zones, adjacent to the visible multifocal choroiditis/punctate inner choroidopathy lesions. The corresponding areas were hyperautofluorescent on fundus autofluorescence and were associated with corresponding visual field defects. Full-field electroretinogram (available in three cases) showed markedly decreased cone/rod response, and multifocal electroretinogram revealed reduced amplitudes and increased implicit times in two cases. Three patients received no treatment, the remaining were treated with oral corticosteroids (n = 4), oral acyclovir/valacyclovir (n = 2), intravitreal/posterior subtenon triamcinolone acetate (n = 3), and anti-vascular endothelial growth factor (n = 2). Visual recovery occurred in only three cases of whom two were treated. Varying morphological recovery was found in six cases, associated with decrease in hyperautofluorescence on fundus autofluorescence. CONCLUSION Multifocal choroiditis/punctate inner choroidopathy can present with transient or permanent central photoreceptor attenuation/loss. This presentation is likely a variant of multifocal choroiditis/punctate inner choroidopathy with chorioretinal atrophy. Associated changes are best evaluated using multimodal imaging.