47 resultados para underframe hatch
Resumo:
Postmortem computed tomography (pmCT) and pmCT angiography (pmCTA) provide a minimally invasive method to determine the cause of death. Postmortem image-guided biopsy allows for precise sampling of histological specimens. This case study describes the findings of lethal systemic fat embolism (FE) on whole-body unenhanced pmCT, pmCTA, and image-guided biopsy, with autopsy and histopathologic correlation. Unenhanced pmCT revealed a distinct fat level on top of sedimented layers of corpuscular blood particles and serum in the arterial system and pulmonary trunk. Subsequent pmCTA showed reproducible results, and image-guided biopsy confirmed fatal FE. pm CT/pmCTA combined with image-guided biopsy established the cause of death as right heart failure as a result of systemic fatal FE prior to autopsy. All imaging findings were consistent with traditional autopsy and histological specimens. This unique case demonstrates new imaging findings in massive, fatal FE and highlights that postmortem imaging, supplemented by image-guided biopsy, may detect the cause of death prior to traditional autopsy.
Resumo:
We investigated the feasibility of postmortem percutaneous needle biopsy (PNB) for obtaining pulmonary samples adequate for the study of pulmonary fat embolism (PFE). Samples of both lungs were obtained from 26 cadavers via two different methods: (i) PNB and (ii) the double-edged knife technique, the gold standard at our institute. After water storage and Sudan III staining, six forensic pathologists independently examined all samples for the presence and severity of PFE. The results were compared and analyzed in each case regarding the vitality of the PFE and its relationship to the cause of death. The results showed that PFE was almost identically diagnosed and graded on the samples obtained via both methods. The discrepancies between the two techniques did not affect the diagnoses of vitality or cause of death related to PFE. This study demonstrates the feasibility of the PNB sampling method for the diagnosis and interpretation of PFE in the postmortem setting.
Resumo:
We describe a case of exhumation, performed to investigate the circumstances and cause of death, one year after burial. Post mortem computed tomography (PMCT) revealed a mass in the pharynx. Imaging directed the subsequent forensic autopsy to careful retrieval of a foreign body. Histological analysis revealed a non-cellular composition. The detection of foreign material in the pharynx and its composition indicated accidental, rather than natural death, secondary to choking on food. This unusual case illustrates how post mortem imaging can significantly contribute to forensic investigation and stresses the importance of interdisciplinary collaboration between forensic pathologists and radiologists.
Resumo:
OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.
Resumo:
Sex determination in forensic practice is performed mostly on sexually dimorphic bones, including pelvic bones such as the os sacrum. Postmortem CT scan provides an easy and fast method for depicting and measuring bone structures prior to elaborate autopsy preparations. To develop a simple and objective method for sex determination in postmortem CT, metric data were evaluated from CT images of the pelvic-associated os sacrum of 95 corpses (49 men and 46 women) from the Canton of Bern, Switzerland. Discriminant function analysis of the data showed that the best accuracy in determining sex was 76.8% and 78.9% with two different observers. It is concluded that measuring the os sacrumin postmortem CT for sex determination has moderate accuracy and should only be applied in combination with other methods.
Resumo:
Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease.
Resumo:
The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.
Resumo:
We describe a case of a fatal speed flying accident in which the victim was electrocuted, burned and fell from a great height. Post-mortem imaging revealed acute appearing fractures on CT, without bone marrow oedema on MRI. Based on the known clinical imaging findings of bone marrow oedema in acute fractures, we concluded that the speed flyer died from electrocution rather than the fall and that the fractures occurred post-mortem. Radiological imaging augmented the reconstruction of the peri-mortem events. Further research is needed to assess whether bone marrow oedema in acute fractures is a reliable vital sign.
Resumo:
The objective of this study was to explore the perception of the legal authorities regarding different report types and visualization techniques for post-mortem radiological findings.
Resumo:
For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.
Resumo:
The media and the Internet may be having an influence on suicidal behavior. Online social networks such as Facebook represent a new facet of global information transfer. The impact of these online social networks on suicidal behavior has not yet been evaluated.
Resumo:
To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures.
Resumo:
To assess the reliability of radiologic identification using visual comparison of ante and post mortem paranasal sinus computed tomography (CT).
Resumo:
There are conflicting results with regard to the use of catheter-based techniques for continuous paravertebral block. Local anaesthetic spread within the paravertebral space is limited and the clinical effect is often variable. Discrepancies between needle tip position and final catheter position can also be problematic. The aim of this proof-of-concept study was to assess the reliability of placing a newly developed coiled catheter in human cadavers. Sixty Tuohy needles and coiled catheters were placed under ultrasound guidance, three on each side of the thoracic vertebral column in 10 human cadavers. Computed tomography was used to assess needle tip and catheter tip locations. No catheter was misplaced into the epidural, pleural or prevertebral spaces. The mean (SD) distance between catheter tips and needle tips was 8.2 (4.9) mm. The median (IQR [range]) caudo-cephalad spread of contrast dye injectate through a subset of 20 catheters was 4 (4-5[3-8]) thoracic segments. All catheters were removed without incident. Precise paravertebral catheter placement can be achieved using ultrasound-guided placement of a coiled catheter.
Resumo:
Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.