36 resultados para the Fuzzy Colour Segmentation Algorithm
Resumo:
Osteoarticular allograft transplantation is a popular treatment method in wide surgical resections with large defects. For this reason hospitals are building bone data banks. Performing the optimal allograft selection on bone banks is crucial to the surgical outcome and patient recovery. However, current approaches are very time consuming hindering an efficient selection. We present an automatic method based on registration of femur bones to overcome this limitation. We introduce a new regularization term for the log-domain demons algorithm. This term replaces the standard Gaussian smoothing with a femur specific polyaffine model. The polyaffine femur model is constructed with two affine (femoral head and condyles) and one rigid (shaft) transformation. Our main contribution in this paper is to show that the demons algorithm can be improved in specific cases with an appropriate model. We are not trying to find the most optimal polyaffine model of the femur, but the simplest model with a minimal number of parameters. There is no need to optimize for different number of regions, boundaries and choice of weights, since this fine tuning will be done automatically by a final demons relaxation step with Gaussian smoothing. The newly developed synthesis approach provides a clear anatomically motivated modeling contribution through the specific three component transformation model, and clearly shows a performance improvement (in terms of anatomical meaningful correspondences) on 146 CT images of femurs compared to a standard multiresolution demons. In addition, this simple model improves the robustness of the demons while preserving its accuracy. The ground truth are manual measurements performed by medical experts.
Resumo:
The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.
Resumo:
BACKGROUND: This study investigated the role of a negative FAST in the diagnostic and therapeutic algorithm of multiply injured patients with liver or splenic lesions. METHODS: A retrospective analysis of 226 multiply injured patients with liver or splenic lesions treated at Bern University Hospital, Switzerland. RESULTS: FAST failed to detect free fluid or organ lesions in 45 of 226 patients with spleen or liver injuries (sensitivity 80.1%). Overall specificity was 99.5%. The positive and negative predictive values were 99.4% and 83.3%. The overall likelihood ratios for a positive and negative FAST were 160.2 and 0.2. Grade III-V organ lesions were detected more frequently than grade I and II lesions. Without the additional diagnostic accuracy of a CT scan, the mean ISS of the FAST-false-negative patients would be significantly underestimated and 7 previously unsuspected intra-abdominal injuries would have been missed. CONCLUSION: FAST is an expedient tool for the primary assessment of polytraumatized patients to rule out high grade intra-abdominal injuries. However, the low overall diagnostic sensitivity of FAST may lead to underestimated injury patterns and delayed complications may occur. Hence, in hemodynamically stable patients with abdominal trauma, an early CT scan should be considered and one must be aware of the potential shortcomings of a "negative FAST".
Resumo:
The fuzzy online reputation analysis framework, or “foRa” (plural of forum, the Latin word for marketplace) framework, is a method for searching the Social Web to find meaningful information about reputation. Based on an automatic, fuzzy-built ontology, this framework queries the social marketplaces of the Web for reputation, combines the retrieved results, and generates navigable Topic Maps. Using these interactive maps, communications operatives can zero in on precisely what they are looking for and discover unforeseen relationships between topics and tags. Thus, using this framework, it is possible to scan the Social Web for a name, product, brand, or combination thereof and determine query-related topic classes with related terms and thus identify hidden sources. This chapter also briefly describes the youReputation prototype (www.youreputation.org), a free web-based application for reputation analysis. In the course of this, a small example will explain the benefits of the prototype.
Resumo:
This paper uses folksonomies and fuzzy clustering algorithms to establish term-relevant related results. This paper will propose a Meta search engine with the ability to search for vaguely associated terms and aggregate them into several meaningful cluster categories. The potential of the fuzzy weblog extraction is illustrated using a simple example and added value and possible future studies are discussed in the conclusion.
Resumo:
We propose a new mechanism for diversification of male nuptial–colour patterns in the rapidly speciating cichlid fishes of Lake Victoria. Sympatric closely related species often display nuptial colours at opposite ends of the spectrum with males either blue or yellow to red. Colour polymorphisms within single populations are common too. We propose that competition between males for breeding sites promotes such colour diversification, and thereby speciation. We hypothesize that male aggression is primarily directed towards males of the common colour, and that rare colour morphs enjoy a negatively frequency–dependent fitness advantage. We test our hypothesis with a large dataset on the distributions and nuptial colorations of 52 species on 47 habitat islands in Lake Victoria, and with a smaller dataset on the within–spawning–site distributions of males with different coloration. We report that territories of males of the same colour are negatively associated on the spawning site, and that the distribution of closely related species over habitat islands is determined by nuptial coloration in the fashion predicted by our hypothesis. Whereas among unrelated species those with similar nuptial colour are positively associated, among closely related species those with similar colour are negatively associated and those with different colour are positively associated. This implies that negatively frequency–dependent selection on nuptial coloration among closely related species is a sufficiently strong force to override other effects on species distributions. We suggest that male–male competition is an important and previously neglected agent of diversification among haplochromine cichlid fishes.
Resumo:
Several approaches for the non-invasive MRI-based measurement of the aortic pressure waveform over the heart cycle have been proposed in the last years. These methods are normally based on time-resolved, two-dimensional phase-contrast sequences with uni-directionally encoded velocities (2D PC-MRI). In contrast, three-dimensional acquisitions with tridirectional velocity encoding (4D PC-MRI) have been shown to be a suitable data source for detailed investigations of blood flow and spatial blood pressure maps. In order to avoid additional MR acquisitions, it would be advantageous if the aortic pressure waveform could also be computed from this particular form of MRI. Therefore, we propose an approach for the computation of the aortic pressure waveform which can be completely performed using 4D PC-MRI. After the application of a segmentation algorithm, the approach automatically computes the aortic pressure waveform without any manual steps. We show that our method agrees well with catheter measurements in an experimental phantom setup and produces physiologically realistic results in three healthy volunteers.
Resumo:
Background: Patients presenting to the emergency department (ED) currently face inacceptable delays in initial treatment, and long, costly hospital stays due to suboptimal initial triage and site-of-care decisions. Accurate ED triage should focus not only on initial treatment priority, but also on prediction of medical risk and nursing needs to improve site-of-care decisions and to simplify early discharge management. Different triage scores have been proposed, such as the Manchester triage system (MTS). Yet, these scores focus only on treatment priority, have suboptimal performance and lack validation in the Swiss health care system. Because the MTS will be introduced into clinical routine at the Kantonsspital Aarau, we propose a large prospective cohort study to optimize initial patient triage. Specifically, the aim of this trial is to derive a three-part triage algorithm to better predict (a) treatment priority; (b) medical risk and thus need for in-hospital treatment; (c) post-acute care needs of patients at the most proximal time point of ED admission. Methods/design: Prospective, observational, multicenter, multi-national cohort study. We will include all consecutive medical patients seeking ED care into this observational registry. There will be no exclusions except for non-adult and non-medical patients. Vital signs will be recorded and left over blood samples will be stored for later batch analysis of blood markers. Upon ED admission, the post-acute care discharge score (PACD) will be recorded. Attending ED physicians will adjudicate triage priority based on all available results at the time of ED discharge to the medical ward. Patients will be reassessed daily during the hospital course for medical stability and readiness for discharge from the nurses and if involved social workers perspective. To assess outcomes, data from electronic medical records will be used and all patients will be contacted 30 days after hospital admission to assess vital and functional status, re-hospitalization, satisfaction with care and quality of life measures. We aim to include between 5000 and 7000 patients over one year of recruitment to derive the three-part triage algorithm. The respective main endpoints were defined as (a) initial triage priority (high vs. low priority) adjudicated by the attending ED physician at ED discharge, (b) adverse 30 day outcome (death or intensive care unit admission) within 30 days following ED admission to assess patients risk and thus need for in-hospital treatment and (c) post acute care needs after hospital discharge, defined as transfer of patients to a post-acute care institution, for early recognition and planning of post-acute care needs. Other outcomes are time to first physician contact, time to initiation of adequate medical therapy, time to social worker involvement, length of hospital stay, reasons fordischarge delays, patient’s satisfaction with care, overall hospital costs and patients care needs after returning home. Discussion: Using a reliable initial triage system for estimating initial treatment priority, need for in-hospital treatment and post-acute care needs is an innovative and persuasive approach for a more targeted and efficient management of medical patients in the ED. The proposed interdisciplinary , multi-national project has unprecedented potential to improve initial triage decisions and optimize resource allocation to the sickest patients from admission to discharge. The algorithms derived in this study will be compared in a later randomized controlled trial against a usual care control group in terms of resource use, length of hospital stay, overall costs and patient’s outcomes in terms of mortality, re-hospitalization, quality of life and satisfaction with care.
Resumo:
BACKGROUND AND PURPOSE Reproducible segmentation of brain tumors on magnetic resonance images is an important clinical need. This study was designed to evaluate the reliability of a novel fully automated segmentation tool for brain tumor image analysis in comparison to manually defined tumor segmentations. METHODS We prospectively evaluated preoperative MR Images from 25 glioblastoma patients. Two independent expert raters performed manual segmentations. Automatic segmentations were performed using the Brain Tumor Image Analysis software (BraTumIA). In order to study the different tumor compartments, the complete tumor volume TV (enhancing part plus non-enhancing part plus necrotic core of the tumor), the TV+ (TV plus edema) and the contrast enhancing tumor volume CETV were identified. We quantified the overlap between manual and automated segmentation by calculation of diameter measurements as well as the Dice coefficients, the positive predictive values, sensitivity, relative volume error and absolute volume error. RESULTS Comparison of automated versus manual extraction of 2-dimensional diameter measurements showed no significant difference (p = 0.29). Comparison of automated versus manual segmentation of volumetric segmentations showed significant differences for TV+ and TV (p<0.05) but no significant differences for CETV (p>0.05) with regard to the Dice overlap coefficients. Spearman's rank correlation coefficients (ρ) of TV+, TV and CETV showed highly significant correlations between automatic and manual segmentations. Tumor localization did not influence the accuracy of segmentation. CONCLUSIONS In summary, we demonstrated that BraTumIA supports radiologists and clinicians by providing accurate measures of cross-sectional diameter-based tumor extensions. The automated volume measurements were comparable to manual tumor delineation for CETV tumor volumes, and outperformed inter-rater variability for overlap and sensitivity.
Resumo:
Measurements of inclusive jet suppression in heavy ion collisions at the LHC provide direct sensitivity to the physics of jet quenching. In a sample of lead-lead collisions at root S-NN = 2.76 TeV corresponding to an integrated luminosity of approximately 7 mu b(-1), ATLAS has measured jets with a calorimeter system over the pseudorapidity interval vertical bar eta vertical bar < 2.1 and over the transverse momentum range 38 < pT <210 GeV. Jets were reconstructed using the anti-k(t) algorithm with values for the distance parameter that determines the nominal jet radius of R = 0.2, 0.3, 0.4 and 0.5. The centrality dependence of the jet yield is characterized by the jet "central-to-peripheral ratio," R-CP. Jet production is found to be suppressed by approximately a factor of two in the 10% most central collisions relative to peripheral collisions. R-CP varies smoothly with centrality as characterized by the number of participating nucleons. The observed suppression is only weakly dependent on jet radius and transverse momentum. These results provide the first direct measurement of inclusive jet suppression in heavy ion collisions and complement previous measurements of dijet transverse energy imbalance at the LHC.
Resumo:
The inclusive jet cross-section has been measured in proton-proton collisions at root s = 2.76 TeV in a dataset corresponding to an integrated luminosity of 0.20 pb(-1) collected with the ATLAS detector at the Large Hadron Collider in 2011. Jets are identified using the anti-k(t) algorithm with two radius parameters of 0.4 and 0.6. The inclusive jet double-differential cross-section is presented as a function of the jet transverse momentum p(T) and jet rapidity y, covering a range of 20 <= p(T) < 430 GeV and vertical bar y vertical bar < 4.4. The ratio of the cross-section to the inclusive jet cross-section measurement at root s = 7 TeV, published by the ATLAS Collaboration, is calculated as a function of both transverse momentum and the dimensionless quantity x(T) = 2p(T)/root s, in bins of jet rapidity. The systematic uncertainties on the ratios are significantly reduced due to the cancellation of correlated uncertainties in the two measurements. Results are compared to the prediction from next-to-leading order perturbative QCD calculations corrected for non-perturbative effects, and next-to-leading order Monte Carlo simulation. Furthermore, the ATLAS jet cross-section measurements at root s = 2.76 TeV and root s = 7 TeV are analysed within a framework of next-to-leading order perturbative QCD calculations to determine parton distribution functions of the proton, taking into account the correlations between the measurements.
Resumo:
Manual counting of bacterial colony forming units (CFUs) on agar plates is laborious and error-prone. We therefore implemented a colony counting system with a novel segmentation algorithm to discriminate bacterial colonies from blood and other agar plates.A colony counter hardware was designed and a novel segmentation algorithm was written in MATLAB. In brief, pre-processing with Top-Hat-filtering to obtain a uniform background was followed by the segmentation step, during which the colony images were extracted from the blood agar and individual colonies were separated. A Bayes classifier was then applied to count the final number of bacterial colonies as some of the colonies could still be concatenated to form larger groups. To assess accuracy and performance of the colony counter, we tested automated colony counting of different agar plates with known CFU numbers of S. pneumoniae, P. aeruginosa and M. catarrhalis and showed excellent performance.
Resumo:
Instruments for on-farm determination of colostrum quality such as refractometers and densimeters are increasingly used in dairy farms. The colour of colostrum is also supposed to reflect its quality. A paler or mature milk-like colour is associated with a lower colostrum value in terms of its general composition compared with a more yellowish and darker colour. The objective of this study was to investigate the relationships between colour measurement of colostrum using the CIELAB colour space (CIE L*=from white to black, a*=from red to green, b*=from yellow to blue, chroma value G=visual perceived colourfulness) and its composition. Dairy cow colostrum samples (n=117) obtained at 4·7±1·5 h after parturition were analysed for immunoglobulin G (IgG) by ELISA and for fat, protein and lactose by infrared spectroscopy. For colour measurements, a calibrated spectrophotometer was used. At a cut-off value of 50 mg IgG/ml, colour measurement had a sensitivity of 50·0%, a specificity of 49·5%, and a negative predictive value of 87·9%. Colostral IgG concentration was not correlated with the chroma value G, but with relative lightness L*. While milk fat content showed a relationship to the parameters L*, a*, b* and G from the colour measurement, milk protein content was not correlated with a*, but with L*, b*, and G. Lactose concentration in colostrum showed only a relationship with b* and G. In conclusion, parameters of the colour measurement showed clear relationships to colostral IgG, fat, protein and lactose concentration in dairy cows. Implementation of colour measuring devices in automatic milking systems and milking parlours might be a potential instrument to access colostrum quality as well as detecting abnormal milk.
Resumo:
Extraction of both pelvic and femoral surface models of a hip joint from CT data for computer-assisted pre-operative planning of hip arthroscopy is addressed. We present a method for a fully automatic image segmentation of a hip joint. Our method works by combining fast random forest (RF) regression based landmark detection, atlas-based segmentation, with articulated statistical shape model (aSSM) based hip joint reconstruction. The two fundamental contributions of our method are: (1) An improved fast Gaussian transform (IFGT) is used within the RF regression framework for a fast and accurate landmark detection, which then allows for a fully automatic initialization of the atlas-based segmentation; and (2) aSSM based fitting is used to preserve hip joint structure and to avoid penetration between the pelvic and femoral models. Validation on 30 hip CT images show that our method achieves high performance in segmenting pelvis, left proximal femur, and right proximal femur surfaces with an average accuracy of 0.59 mm, 0.62 mm, and 0.58 mm, respectively.
Resumo:
We studied the effect of male coloration on interspeciÆc female mate choice in two closely related species of haplochromine cichlids from Lake Victoria. The species differ primarily in male coloration. Males of one species are red, those of the other are blue. We re- corded the behavioral responses of females to males of both species in paired male trials under white light and under monochromatic light, under which the interspecific differences in coloration were masked. Females of both species exhibited species-assortative mate choice when colour differences were visible, but chose non-assortatively when colour differences were masked by light conditions. Neither male behaviour nor overall female response frequencies differed between light treatments. That female preferences could be altered by manipulating the perceived colour pattern implies that the colour itself is used in interspecific mate choice, rather than other characters. Hence, male coloration in haplochromine cichlids does underlie sexual selection by direct mate choice, involving the capacity for individual assessment of potential mates by the female. Females of both species responded more frequently to blue males under monochromatic light. Blue males were larger and displayed more than red males. This implies a hierarchy of choice criteria. Females may use male display rates, size, or both when colour is unavailable. Where available, colour has gained dominance over other criteria. This may explain rapid speciation by sexual selection on male coloration, as proposed in a recent mathematical model.