29 resultados para statistical analysis


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. MATERIALS AND METHODS: Stability measurements by means of RFA were performed in regularly followed patients who had received 1- stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P <.0125). RESULTS: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. CONCLUSIONS: A mean ISQ of 64.5 +/- 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: This study analyzed the impact of weight reduction method, preoperative, and intraoperative variables on the outcome of reconstructive body contouring surgery following massive weight reduction. METHODS: All patients presenting with a maximal BMI >/=35 kg/m(2) before weight reduction who underwent body contouring surgery of the trunk following massive weight loss (excess body mass index loss (EBMIL) >/= 30%) between January 2002 and June 2007 were retrospectively analyzed. Incomplete records or follow-up led to exclusion. Statistical analysis focused on weight reduction method and pre-, intra-, and postoperative risk factors. The outcome was compared to current literature results. RESULTS: A total of 104 patients were included (87 female and 17 male; mean age 47.9 years). Massive weight reduction was achieved through bariatric surgery in 62 patients (59.6%) and dietetically in 42 patients (40.4%). Dietetically achieved excess body mass index loss (EBMIL) was 94.20% and in this cohort higher than surgically induced reduction EBMIL 80.80% (p < 0.01). Bariatric surgery did not present increased risks for complications for the secondary body contouring procedures. The observed complications (26.9%) were analyzed for risk factors. Total tissue resection weight was a significant risk factor (p < 0.05). Preoperative BMI had an impact on infections (p < 0.05). No impact on the postoperative outcome was detected in EBMIL, maximal BMI, smoking, hemoglobin, blood loss, body contouring technique or operation time. Corrective procedures were performed in 11 patients (10.6%). The results were compared to recent data. CONCLUSION: Bariatric surgery does not increase risks for complications in subsequent body contouring procedures when compared to massive dietetic weight reduction.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Little is known about the pathologic changes in the epidural space after intervertebral disk (IVD) extrusion in the dog. OBJECTIVES To analyze the pathology of the epidural inflammatory response, and to search for correlations between this process and clinical findings. METHODS Clinical data from 105 chondrodystrophic (CD) and nonchondrodystrophic (NCD) dogs with IVD extrusion were recorded. Epidural material from these dogs was examined histopathologically and immunohistochemically. Using statistical analysis, we searched for correlations between severity of epidural inflammation and various clinical and pathologic variables. RESULTS Most dogs exhibited an epidural inflammatory response, ranging from acute invasion of neutrophils to formation of chronic granulation tissue. The mononuclear inflammatory infiltrates consisted mostly of monocytes and macrophages and only few T and B cells. Surprisingly, chronic inflammatory patterns also were found in animals with an acute clinical history. Severity of the epidural inflammation correlated with degree of the epidural hemorrhage and nucleus pulposus calcification (P = .003 and .040), but not with age, chondrodystrophic phenotype, neurologic grade, back pain, pretreatment, or duration. The degree of inflammation was statistically (P = .021) inversely correlated with the ability to regain ambulation. CONCLUSION AND CLINICAL IMPORTANCE Epidural inflammation occurs in the majority of dogs with IVD extrusion and may develop long before the onset of clinical signs. Presence of calcified IVD material and hemorrhage in the epidural space may be the triggers of this lesion rather than an adaptive immune response to the nucleus pulposus as suggested in previous studies. Because epidural inflammation may affect outcome, further research is warranted.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The vestibular system contributes to the control of posture and eye movements and is also involved in various cognitive functions including spatial navigation and memory. These functions are subtended by projections to a vestibular cortex, whose exact location in the human brain is still a matter of debate (Lopez and Blanke, 2011). The vestibular cortex can be defined as the network of all cortical areas receiving inputs from the vestibular system, including areas where vestibular signals influence the processing of other sensory (e.g. somatosensory and visual) and motor signals. Previous neuroimaging studies used caloric vestibular stimulation (CVS), galvanic vestibular stimulation (GVS), and auditory stimulation (clicks and short-tone bursts) to activate the vestibular receptors and localize the vestibular cortex. However, these three methods differ regarding the receptors stimulated (otoliths, semicircular canals) and the concurrent activation of the tactile, thermal, nociceptive and auditory systems. To evaluate the convergence between these methods and provide a statistical analysis of the localization of the human vestibular cortex, we performed an activation likelihood estimation (ALE) meta-analysis of neuroimaging studies using CVS, GVS, and auditory stimuli. We analyzed a total of 352 activation foci reported in 16 studies carried out in a total of 192 healthy participants. The results reveal that the main regions activated by CVS, GVS, or auditory stimuli were located in the Sylvian fissure, insula, retroinsular cortex, fronto-parietal operculum, superior temporal gyrus, and cingulate cortex. Conjunction analysis indicated that regions showing convergence between two stimulation methods were located in the median (short gyrus III) and posterior (long gyrus IV) insula, parietal operculum and retroinsular cortex (Ri). The only area of convergence between all three methods of stimulation was located in Ri. The data indicate that Ri, parietal operculum and posterior insula are vestibular regions where afferents converge from otoliths and semicircular canals, and may thus be involved in the processing of signals informing about body rotations, translations and tilts. Results from the meta-analysis are in agreement with electrophysiological recordings in monkeys showing main vestibular projections in the transitional zone between Ri, the insular granular field (Ig), and SII.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, reconstruction of three-dimensional (3D) patient-specific models of a hip joint from two-dimensional (2D) calibrated X-ray images is addressed. Existing 2D-3D reconstruction techniques usually reconstruct a patient-specific model of a single anatomical structure without considering the relationship to its neighboring structures. Thus, when those techniques would be applied to reconstruction of patient-specific models of a hip joint, the reconstructed models may penetrate each other due to narrowness of the hip joint space and hence do not represent a true hip joint of the patient. To address this problem we propose a novel 2D-3D reconstruction framework using an articulated statistical shape model (aSSM). Different from previous work on constructing an aSSM, where the joint posture is modeled as articulation in a training set via statistical analysis, here it is modeled as a parametrized rotation of the femur around the joint center. The exact rotation of the hip joint as well as the patient-specific models of the joint structures, i.e., the proximal femur and the pelvis, are then estimated by optimally fitting the aSSM to a limited number of calibrated X-ray images. Taking models segmented from CT data as the ground truth, we conducted validation experiments on both plastic and cadaveric bones. Qualitatively, the experimental results demonstrated that the proposed 2D-3D reconstruction framework preserved the hip joint structure and no model penetration was found. Quantitatively, average reconstruction errors of 1.9 mm and 1.1 mm were found for the pelvis and the proximal femur, respectively.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Chronic haemodialysis patients are a high-risk population for meticillin-resistant Staphylococcus aureus (MRSA) colonization, which is a precursor of infection. AIM To summarize the effect of nasal (± whole-body wash) MRSA decolonization in haemodialysis patients by means of a systematic review and meta-analysis. METHODS We identified eligible studies using Medline, Embase, the Cochrane database, clinicaltrials.org, and conference abstracts investigating the success of MRSA decolonization in haemodialysis patients. For the statistical analysis, we used Stata 13 to express study-specific proportions with 95% confidence intervals. A likelihood ratio test was used to assess inter-study heterogeneity. FINDINGS Six published prospective cohort studies and one study described in a conference abstract met our inclusion criteria. From 1150 haemodialysis patients enrolled in these studies, MRSA was isolated from nasal swabs of 147 (12.8%) patients. Six of the trials used mupirocin nasal ointment and combined it with chlorhexidine body washes for decolonization. The most widely used protocol was a five-day course of mupirocin nasal ointment application three times a day, and chlorhexidine body wash once daily. The pooled success rate of decolonization was 0.88 (95% confidence interval: 0.75-0.95). A likelihood ratio test of the fixed versus the random-effects model showed significant inter-study heterogeneity (P = 0.047). Four of seven studies determined subsequent MRSA infections in 94 carriers overall, two (2%) of which experienced infection. CONCLUSION The use of mupirocin together with whole-body decolonization is highly effective in eradicating MRSA carriage in haemodialysis patients. The current literature, however, is characterized by a lack of comparative effectiveness studies for this intervention.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND The Endoscopic Release of Carpal Tunnel Syndrome (ECTR) is a minimal invasive approach for the treatment of Carpal Tunnel Syndrome. There is scepticism regarding the safety of this technique, based on the assumption that this is a rather "blind" procedure and on the high number of severe complications that have been reported in the literature. PURPOSE To evaluate whether there is evidence supporting a higher risk after ECTR in comparison to the conventional open release. METHODS We searched MEDLINE (January 1966 to November 2013), EMBASE (January 1980 to November 2013), the Cochrane Neuromuscular Disease Group Specialized Register (November 2013) and CENTRAL (2013, issue 11 in The Cochrane Library). We hand-searched reference lists of included studies. We included all randomized or quasi-randomized controlled trials (e.g. study using alternation, date of birth, or case record number) that compare any ECTR with any OCTR technique. Safety was assessed by the incidence of major, minor and total number of complications, recurrences, and re-operations.The total time needed before return to work or to return to daily activities was also assessed. We synthesized data using a random-effects meta-analysis in STATA. We conducted a sensitivity analysis for rare events using binomial likelihood. We judged the conclusiveness of meta-analysis calculating the conditional power of meta-analysis. CONCLUSIONS ECTR is associated with less time off work or with daily activities. The assessment of major complications, reoperations and recurrence of symptoms does not favor either of the interventions. There is an uncertain advantage of ECTR with respect to total minor complications (more transient paresthesia but fewer skin-related complications). Future studies are unlikely to alter these findings because of the rarity of the outcome. The effect of a learning curve might be responsible for reduced recurrences and reoperations with ECTR in studies that are more recent, although formal statistical analysis failed to provide evidence for such an association. LEVEL OF EVIDENCE I.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Protein-energy-malnutrition (PEM) is common in people with end stage kidney disease (ESKD) undergoing maintenance haemodialysis (MHD) and correlates strongly with mortality. To this day, there is no gold standard for detecting PEM in patients on MHD. Aim of Study The aim of this study was to evaluate if Nutritional Risk Screening 2002 (NRS-2002), handgrip strength measurement, mid-upper arm muscle area (MUAMA), triceps skin fold measurement (TSF), serum albumin, normalised protein catabolic rate (nPCR), Kt/V and eKt/V, dry body weight, body mass index (BMI), age and time since start on MHD are relevant for assessing PEM in patients on MHD. Methods The predictive value of the selected parameters on mortality and mortality or weight loss of more than 5% was assessed. Quantitative data analysis of the 12 parameters in the same patients on MHD in autumn 2009 (n = 64) and spring 2011 (n = 40) with paired statistical analysis and multivariate logistic regression analysis was performed. Results Paired data analysis showed significant reduction of dry body weight, BMI and nPCR. Kt/Vtot did not change, eKt/v and hand grip strength measurements were significantly higher in spring 2011. No changes were detected in TSF, serum albumin, NRS-2002 and MUAMA. Serum albumin was shown to be the only predictor of death and of the combined endpoint “death or weight loss of more than 5%”. Conclusion We now screen patients biannually for serum albumin, nPCR, Kt/V, handgrip measurement of the shunt-free arm, dry body weight, age and time since initiation of MHD.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: In equine laminitis, the deep digital flexor muscle (DDFM) appears to have increased muscle force, but evidence-based confirmation is lacking. OBJECTIVES: The purpose of this study was to test if the DDFM of laminitic equines has an increased muscle force detectable by needle electromyography interference pattern analysis (IPA). ANIMALS AND METHODS: The control group included six Royal Dutch Sport horses, three Shetland ponies and one Welsh pony [10 healthy, sound adults weighing 411 ± 217 kg (mean ± SD) and aged 10 ± 5 years]. The laminitic group included three Royal Dutch Sport horses, one Friesian, one Haflinger, one Icelandic horse, one Welsh pony, one miniature Appaloosa and six Shetland ponies (14 adults, weight 310 ± 178 kg, aged 13 ± 6 years) with acute/chronic laminitis. The electromyography IPA measurements included firing rate, turns/second (T), amplitude/turn (M) and M/T ratio. Statistical analysis used a general linear model with outcomes transformed to geometric means. RESULTS: The firing rate of the total laminitic group was higher than the total control group. This difference was smaller for the ponies compared to the horses; in the horses, the geometric mean difference of the laminitic group was 1.73 [geometric 95% confidence interval (CI) 1.29-2.32], and in the ponies this value was 1.09 (geometric 95% CI 0.82-1.45). CONCLUSION AND CLINICAL RELEVANCE: In human medicine, an increased firing rate is characteristic of increased muscle force. Thus, the increased firing rate of the DDFM in the context of laminitis suggests an elevated muscle force. However, this seems to be only a partial effect as in this study, the unchanged turns/second and amplitude/turn failed to prove the recruitment of larger motor units with larger amplitude motor unit potentials in laminitic equids.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES To determine the relationship between nasolabial symmetry and esthetics in subjects with orofacial clefts. MATERIAL AND METHODS Eighty-four subjects (mean age 10 years, standard deviation 1.5) with various types of nonsyndromic clefts were included: 11 had unilateral cleft lip (UCL); 30 had unilateral cleft lip and alveolus (UCLA); and 43 had unilateral cleft lip, alveolus, and palate (UCLAP). A 3D stereophotogrammetric image of the face was taken for each subject. Symmetry and esthetics were evaluated on cropped 3D facial images. The degree of asymmetry of the nasolabial area was calculated based on all 3D data points using a surface registration algorithm. Esthetic ratings of various elements of nasal morphology were performed by eight lay raters on a 100 mm visual analog scale. Statistical analysis included ANOVA tests and regression models. RESULTS Nasolabial asymmetry increased with growing severity of the cleft (p = 0.029). Overall, nasolabial appearance was affected by nasolabial asymmetry; subjects with more nasolabial asymmetry were judged as having a less esthetically pleasing nasolabial area (p < 0.001). However, the relationship between nasolabial symmetry and esthetics was relatively weak in subjects with UCLAP, in whom only vermilion border esthetics was associated with asymmetry. CONCLUSIONS Nasolabial symmetry assessed with 3D facial imaging can be used as an objective measure of treatment outcome in subjects with less severe cleft deformity. In subjects with more severe cleft types, other factors may play a decisive role. CLINICAL SIGNIFICANCE Assessment of nasolabial symmetry is a useful measure of treatment success in less severe cleft types.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES To assess the presence of within-group comparisons with baseline in a subset of leading dental journals and to explore possible associations with a range of study characteristics including journal and study design. STUDY DESIGN AND SETTING Thirty consecutive issues of five leading dental journals were electronically searched. The conduct and reporting of statistical analysis in respect of comparisons against baseline or otherwise along with the manner of interpretation of the results were assessed. Descriptive statistics were obtained, and chi-square test and Fisher's exact were undertaken to test the association between trial characteristics and overall study interpretation. RESULTS A total of 184 studies were included with the highest proportion published in Journal of Endodontics (n = 84, 46%) and most involving a single center (n = 157, 85%). Overall, 43 studies (23%) presented interpretation of their outcomes based solely on comparisons against baseline. Inappropriate use of baseline testing was found to be less likely in interventional studies (P < 0.001). CONCLUSION Use of comparisons with baseline appears to be common among both observational and interventional research studies in dentistry. Enhanced conduct and reporting of statistical tests are required to ensure that inferences from research studies are appropriate and informative.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Detecting lame cows is important in improving animal welfare. Automated tools are potentially useful to enable identification and monitoring of lame cows. The goals of this study were to evaluate the suitability of various physiological and behavioral parameters to automatically detect lameness in dairy cows housed in a cubicle barn. Lame cows suffering from a claw horn lesion (sole ulcer or white line disease) of one claw of the same hind limb (n=32; group L) and 10 nonlame healthy cows (group C) were included in this study. Lying and standing behavior at night by tridimensional accelerometers, weight distribution between hind limbs by the 4-scale weighing platform, feeding behavior at night by the nose band sensor, and heart activity by the Polar device (Polar Electro Oy, Kempele, Finland) were assessed. Either the entire data set or parts of the data collected over a 48-h period were used for statistical analysis, depending upon the parameter in question. The standing time at night over 12 h and the limb weight ratio (LWR) were significantly higher in group C as compared with group L, whereas the lying time at night over 12 h, the mean limb difference (△weight), and the standard deviation (SD) of the weight applied on the limb taking less weight were significantly lower in group C as compared with group L. No significant difference was noted between the groups for the parameters of heart activity and feeding behavior at night. The locomotion score of cows in group L was positively correlated with the lying time and △weight, whereas it was negatively correlated with LWR and SD. The highest sensitivity (0.97) for lameness detection was found for the parameter SD [specificity of 0.80 and an area under the curve (AUC) of 0.84]. The highest specificity (0.90) for lameness detection was present for Δweight (sensitivity=0.78; AUC=0.88) and LWR (sensitivity=0.81; AUC=0.87). The model considering the data of SD together with lying time at night was the best predictor of cows being lame, accounting for 40% of the variation in the likelihood of a cow being lame (sensitivity=0.94; specificity=0.80; AUC=0.86). In conclusion, the data derived from the 4-scale-weighing platform, either alone or combined with the lying time at night over 12 h, represent the most valuable parameters for automated identification of lame cows suffering from a claw horn lesion of one individual hind limb.