25 resultados para shoulder exercises


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotic exoskeletons can be used to study and treat patients with neurological impairments. They can guide and support the human limb over a large range of motion, which requires that the movement trajectory of the exoskeleton coincide with the one of the human arm. This is straightforward to achieve for rather simple joints like the elbow, but very challenging for complex joints like the human shoulder, which is comprised by several bones and can exhibit a movement with multiple rotational and translational degrees of freedom. Thus, several research groups have developed different shoulder actuation mechanism. However, there are no experimental studies that directly compare the comfort of two different shoulder actuation mechanisms. In this study, the comfort and the naturalness of the new shoulder actuation mechanism of the ARMin III exoskeleton are compared to a ball-and-socket-type shoulder actuation. The study was conducted in 20 healthy subjects using questionnaires and 3D-motion records to assess comfort and naturalness. The results indicate that the new shoulder actuation is slightly better than a ball-and-socket-type actuation. However, the differences are small, and under the tested conditions, the comfort and the naturalness of the two tested shoulder actuations do not differ a lot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the internet-based teachware mySCM is that students of economics, informatics and industrial engineering get familiar with quantitative methods for supply chain management. Input-output-relationships of various optimization methods can be detected by sampling input values, parameters, and alternative methods for the same problem. Students can gain extra benefits by passing so-called mini-exams that motivate active learning. mySCM can be used for free, round-the-clock, and any place where access to the Internet is available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The critical shoulder angle (CSA) is an indicator of degenerative shoulder pathologies. CSAs above 35° are associated with degenerative rotator cuff disease, whereas values below 30° are common in osteoarthritis of the glenohumeral joint. Measurements are usually performed on radiographs; however, no data have been reported regarding the reliability of CT scan measurements between different readers or the reproducibility of measurements from radiographs to CT scans. The purpose of our study was to clarify whether CSA measurements on radiographs and CT scans of the same patients show similar values. MATERIALS AND METHODS CSA measurements of 60 shoulders (59 patients) were performed on radiographs and multiplanar reconstructions of corresponding CT scans. Inter-reader reliability and inter-method correlation were calculated. RESULTS The mean discrepancy between readers was only 0.2° (SD ±1.0°) on radiographs. CT scan measurements showed a mean discrepancy of 0.3° (SD ±1.2°). The inter-reader reliability was 0.993 for radiographs and 0.989 for CT scans. There was a very strong inter-method correlation between the CSA measured on radiographs and CT scans (Spearman's rho = 0.974). The mean differences between angles on radiographs and CT measurements were -0.05° (SD ±1.2°) and 0.1° (SD ±1.2°), respectively. CONCLUSION Measurements of the CSA on anterior-posterior radiographs and CT scans are highly correlated, and inter-modality differences are negligible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The pathogenesis of full-thickness tears of the rotator cuff remains unclear. Apart from age and trauma, distinct scapular morphologies have been found to be associated with rotator cuff disease. The purpose of the present study was to evaluate whether a score formed using these established risk factors was able to predict the presence of a rotator cuff tear reliably. METHODS We retrospectively assessed a consecutive series of patients with a minimal age of 40 years old, who had true antero-posterior (AP) radiographs of their shoulders, as well as a magnetic resonance (MR) gadolinium-arthrography, between January and December 2011. In all of these patients, the critical shoulder angle (CSA) was determined, and MR images were assessed for the presence of rotator cuff tears. Additionally, the patients' charts were reviewed to obtain details of symptom onset. Based on these factors, the so-called rotator cuff tear (RCT) score was calculated. RESULTS Patients with full-thickness RCTs were significantly older and had significantly larger CSAs than patients with intact rotator cuffs. Multiple logistic regression, using trauma, age and CSA as independent variables, revealed areas under the curve (AUCs) for trauma of 0.55, for age of 0.65 and for CSA of 0.86. The combination of all three factors was the most powerful predictor, with an AUC of 0.92. CONCLUSION Age, trauma and the CSA can accurately predict the presence of a posterosuperior RCT. LEVEL OF EVIDENCE Level IV. Case series with no comparison groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess patients' outcomes after subacromial or glenohumeral injections based on the degree of lateral extension of the acromion. METHODS 307 patients were prospectively included after therapeutic fluoroscopy-guided subacromial (n = 148) or glenohumeral (n = 159) injections with anaesthetic and long-acting corticosteroids. Pre- and post-injection outcomes at 1 week and 1 month were obtained using the 11-point numerical rating scale (NRS) for pain. Lateral extension of the acromion was quantified and categorized by the critical shoulder angle (CSA) and the acromion index (AI) on anteroposterior conventional radiographs. RESULTS Patients' outcomes at 1 week and 1 month were significantly improved (p < 0.001) compared to baseline for subacromial and glenohumeral injection patients. Patients with a CSA <35° showed significantly higher pain reduction 1 month after subacromial injection compared to patients with a CSA >35° (4.2 ± 2.6 vs. 3.2 ± 3.0, p = 0.04). A significant difference in the 1-month NRS change in pain scores is noted for smaller AIs after subacromial injection (4.3 ± 2.8 vs. 2.6 ± 2.9; p = 0.01). No significant association was noted between clinical outcome and the lateral extension of the acromion after glenohumeral joint injections. CONCLUSIONS A short lateral extension of the acromion was associated with better clinical outcomes in subacromial injection patients but not in glenohumeral injection patients. KEY POINTS • Patients' outcomes at 1 month improved significantly compared to baseline for subacromial injections. • Patients' outcomes at 1 month improved significantly compared to baseline for glenohumeral injections. • Short acromial lateralization was associated with better clinical outcome after subacromial injection. • The acromial lateralization was not associated with clinical outcome after glenohumeral injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The critical shoulder angle combines the acromion index and glenoid inclination and has potential to discriminate between shoulders at risk for rotator cuff tear or osteoarthritis and those that are asymptomatic. However, its biomechanics, and particularly the role of the glenoid inclination, are not yet fully understood. METHODS A shoulder simulator was used to analyze the independent influence of glenoid inclination during abduction from 0 to 60°. Spindle motors transferred tension forces by a cable-pulley on human cadaveric humeri. A six-degree-of-freedom force transducer was mounted directly behind the polyethylene glenoid to measure shear and compressive joint reaction force and calculate the instability ratio (ratio of shear and compressive joint reaction force) with the different force ratios of the deltoid and supraspinatus muscles (2:1 and 1:1). A stepwise change in the inclination by 5° increments allowed simulation of a critical shoulder angle range of 20° to 45°. FINDINGS Tilting the glenoid to cranial (increasing the critical shoulder angle) increases the shear joint reaction force and therefore the instability ratio. A balanced force ratio (1:1) between the deltoid and the supraspinatus allowed larger critical shoulder angles before cranial subluxation occurred than did the deltoid-dominant ratio (2:1). INTERPRETATION Glenoid inclination-dependent changes of the critical shoulder angle have a significant impact on superior glenohumeral joint stability. The increased compensatory activity of the rotator cuff to keep the humeral head centered may lead to mechanical overload and could explain the clinically observed association between large angles and degenerative rotator cuff tears.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Pelvic floor rehabilitation is the conservative therapy of choice for women with stress urinary incontinence (SUI). The success rate of surgical procedures in SUI patients with intrinsic sphincter deficiency (ISD) is low. The aim of this study was to analyse the effect of a standardized physiotherapy on patients with SUI and normotonic urethra and ISD. METHODS In this study, 64 patients with ISD and 69 patients with normotonic urethra were enrolled. Maximum urethral pressure (MUCP) >20 cm H2 O was considered as normotonic urethral pressure. Before and after physiotherapy MUCP was measured and cough testing was performed. Additionally, patient reported outcome was assessed using the King's Health Questionnaire (KHQ). For statistical analyses Excel 2010 (Microsoft Inc; Redmond, Washington) and SPSS 20 (SPSS Inc; Chicago, Illinois) for Windows were used. Power calculation was based on the primary endpoint incontinence impact and general health. For power calculation, GraphPad Statmate version 2.00 for Windows was used. RESULTS Sixty-four patients with ISD and 69 patients with normotonic urethra were included in the study. In SUI patients with normotonic and hypotonic urethra KHQ-scores regarding the primary endpoins "general health" and "incontinence impact" significantly improved following standardized physiotherapy. In both groups MUCP increased after physiotherapy. In SUI patients with ISD standardized physiotherapy resulted in a decreased incidence of a positive cough test. CONCLUSIONS Standardized physiotherapy should be offered to patients with SUI and ISD. Long-term results are subject to future studies. Neurourol. Urodynam. © 2015 Wiley Periodicals, Inc.