312 resultados para photon counting detector


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A search has been performed for photons originating in the decay of a neutral long-lived particle, exploiting the capabilities of the ATLAS electromagnetic calorimeter to make precise measurements of the flight direction of photons, as well as the calorimeter's excellent time resolution. The search has been made in the diphoton plus missing transverse energy final state, using the full data sample of 4.8 fb(-1) of 7 TeV proton-proton collisions collected in 2011 with the ATLAS detector at the LHC. No excess is observed above the background expected from Standard Model processes. The results are used to set exclusion limits in the context of gauge mediated supersymmetry breaking models, with the lightest neutralino being the next-to-lightest supersymmetric particle and decaying with a lifetime in excess of 0.25 ns into a photon and a gravitino.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The integrated and differential fiducial cross sections for the production of a W or Z boson in association with a high-energy photon are measured using pp collisions at root s = 7 TeV. The analyses use a data sample with an integrated luminosity of 4.6 fb(-1) collected by the ATLAS detector during the 2011 LHC data-taking period. Events are selected using leptonic decays of the W and Z bosons [W(e nu, mu nu) and Z(e(+)e(-), mu(+)mu(-), nu(nu) over bar)] with the requirement of an associated isolated photon. The data are used to test the electroweak sector of the Standard Model and search for evidence for new phenomena. The measurements are used to probe the anomalous WW gamma, ZZ gamma, and Z gamma gamma triple-gauge-boson couplings and to search for the production of vector resonances decaying to Z gamma and W gamma. No deviations from Standard Model predictions are observed and limits are placed on anomalous triple-gauge-boson couplings and on the production of new vector meson resonances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A search has been performed, using the full 20.3  fb −1 data sample of 8 TeV proton-proton collisions collected in 2012 with the ATLAS detector at the LHC, for photons originating from a displaced vertex due to the decay of a neutral long-lived particle into a photon and an invisible particle. The analysis investigates the diphoton plus missing transverse momentum final state, and is therefore most sensitive to pair production of long-lived particles. The analysis technique exploits the capabilities of the ATLAS electromagnetic calorimeter to make precise measurements of the flight direction, as well as the time of flight, of photons. No excess is observed over the Standard Model predictions for background. Exclusion limits are set within the context of gauge mediated supersymmetry breaking models, with the lightest neutralino being the next-to-lightest supersymmetric particle and decaying into a photon and gravitino with a lifetime in the range from 250 ps to about 100 ns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of the production processes of the recently discovered Higgs boson is performed in the two-photon final state using 4.5  fb −1 of proton-proton collisions data at s √ =7  TeV and 20.3  fb −1 at s √ =8  TeV collected by the ATLAS detector at the Large Hadron Collider. The number of observed Higgs boson decays to diphotons divided by the corresponding Standard Model prediction, called the signal strength, is found to be μ=1.17±0.27 at the value of the Higgs boson mass measured by ATLAS, m H =125.4  GeV . The analysis is optimized to measure the signal strengths for individual Higgs boson production processes at this value of m H . They are found to be μ ggF =1.32±0.38 , μ VBF =0.8±0.7 , μ WH =1.0±1.6 , μ ZH =0.1 +3.7 −0.1 , and μ tt ¯ H =1.6 +2.7 −1.8 , for Higgs boson production through gluon fusion, vector-boson fusion, and in association with a W or Z boson or a top-quark pair, respectively. Compared with the previously published ATLAS analysis, the results reported here also benefit from a new energy calibration procedure for photons and the subsequent reduction of the systematic uncertainty on the diphoton mass resolution. No significant deviations from the predictions of the Standard Model are found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Letter presents a search for new resonances decaying to final states with a vector boson produced in association with a high transverse momentum photon, Vγ, with V=W(→ℓν)or Z(→ℓ+ℓ−), where ℓ =e or μ. The measurements use 20.3fb−1 of proton–proton collision data at a center-of-mass energy of √s=8TeV recorded with the ATLAS detector. No deviations from the Standard Model expectations are found, and production cross section limits are set at 95% confidence level. Masses of the hypothetical aT and ωT states of a benchmark Low Scale Technicolor model are excluded in the ranges [275, 960] GeVand [200, 700] ∪[750, 890] GeV, respectively. Limits at 95% confidence level on the production cross section of a singlet scalar resonance decaying to Zγ final states have also been obtained for masses below 1180 GeV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of the cross section for the production of isolated prompt photons in pp collisions at a center-of-mass energy s √ =7  TeV is presented. The results are based on an integrated luminosity of 4.6  fb −1 collected with the ATLAS detector at the LHC. The cross section is measured as a function of photon pseudorapidity η γ and transverse energy E γ T in the kinematic range 100≤E γ T <1000  GeV and in the regions |η γ |<1.37 and 1.52≤|η γ |<2.37 . The results are compared to leading-order parton-shower Monte Carlo models and next-to-leading-order perturbative QCD calculations. Next-to-leading-order perturbative QCD calculations agree well with the measured cross sections as a function of E γ T and η γ .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In high energy teletherapy, VMC++ is known to be a very accurate and efficient Monte Carlo (MC) code. In principle, the MC method is also a powerful dose calculation tool in other areas in radiation oncology, e.g., brachytherapy or orthovoltage radiotherapy. However, VMC++ is not validated for the low-energy range of such applications. This work aims in the validation of the VMC++ MC code for photon beams in the energy range between 20 and 1000 keV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was a Monte Carlo (MC) based investigation of the impact of different radiation transport methods in collimators of a linear accelerator on photon beam characteristics, dose distributions, and efficiency. Thereby it is investigated if it is possible to use different simplifications in the radiation transport for some clinical situations in order to save calculation time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbohydrate counting is a principal strategy in nutritional management of type 1 diabetes. The Nutri-Learn buffet (NLB) is a new computer-based tool for patient instruction in carbohydrate counting. It is based on food dummies made of plastic equipped with a microchip containing relevant food content data. The tool enables the dietician to assess the patient's food counting abilities and the patient to learn in a hands-on interactive manner to estimate food contents such as carbohydrate content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.