102 resultados para performance test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Driving a car is a complex instrumental activity of daily living and driving performance is very sensitive to cognitive impairment. The assessment of driving-relevant cognition in older drivers is challenging and requires reliable and valid tests with good sensitivity and specificity to predict safe driving. Driving simulators can be used to test fitness to drive. Several studies have found strong correlation between driving simulator performance and on-the-road driving. However, access to driving simulators is restricted to specialists and simulators are too expensive, large, and complex to allow easy access to older drivers or physicians advising them. An easily accessible, Web-based, cognitive screening test could offer a solution to this problem. The World Wide Web allows easy dissemination of the test software and implementation of the scoring algorithm on a central server, allowing generation of a dynamically growing database with normative values and ensures that all users have access to the same up-to-date normative values. OBJECTIVE In this pilot study, we present the novel Web-based Bern Cognitive Screening Test (wBCST) and investigate whether it can predict poor simulated driving performance in healthy and cognitive-impaired participants. METHODS The wBCST performance and simulated driving performance have been analyzed in 26 healthy younger and 44 healthy older participants as well as in 10 older participants with cognitive impairment. Correlations between the two tests were calculated. Also, simulated driving performance was used to group the participants into good performers (n=70) and poor performers (n=10). A receiver-operating characteristic analysis was calculated to determine sensitivity and specificity of the wBCST in predicting simulated driving performance. RESULTS The mean wBCST score of the participants with poor simulated driving performance was reduced by 52%, compared to participants with good simulated driving performance (P<.001). The area under the receiver-operating characteristic curve was 0.80 with a 95% confidence interval 0.68-0.92. CONCLUSIONS When selecting a 75% test score as the cutoff, the novel test has 83% sensitivity, 70% specificity, and 81% efficiency, which are good values for a screening test. Overall, in this pilot study, the novel Web-based computer test appears to be a promising tool for supporting clinicians in fitness-to-drive assessments of older drivers. The Web-based distribution and scoring on a central computer will facilitate further evaluation of the novel test setup. We expect that in the near future, Web-based computer tests will become a valid and reliable tool for clinicians, for example, when assessing fitness to drive in older drivers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE This study aimed to test the prediction from the Perception and Attention Deficit model of complex visual hallucinations (CVH) that impairments in visual attention and perception are key risk factors for complex hallucinations in eye disease and dementia. METHODS Two studies ran concurrently to investigate the relationship between CVH and impairments in perception (picture naming using the Graded Naming Test) and attention (Stroop task plus a novel Imagery task). The studies were in two populations-older patients with dementia (n = 28) and older people with eye disease (n = 50) with a shared control group (n = 37). The same methodology was used in both studies, and the North East Visual Hallucinations Inventory was used to identify CVH. RESULTS A reliable relationship was found for older patients with dementia between impaired perceptual and attentional performance and CVH. A reliable relationship was not found in the population of people with eye disease. CONCLUSIONS The results add to previous research that object perception and attentional deficits are associated with CVH in dementia, but that risk factors for CVH in eye disease are inconsistent, suggesting that dynamic rather than static impairments in attentional processes may be key in this population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contemporary models of self-regulated learning emphasize the role of distal motivational factors for student's achievement, on the one side, and the proximal role of metacognitive monitoring and control for learning and test outcomes, on the other side. In the present study, two larger samples of elementary school children (9- and 11-year-olds) were included and their mastery-oriented motivation, metacognitive monitoring and control skills were integrated into structural equation models testing and comparing the relative impact of these different constituents for self-regulated learning. For one, results indicate that the factorial structure of monitoring, control and mastery motivation was invariant across the two age groups. Of specific interest was the finding that there were age-dependent structural links between monitoring, control, and test performance (closer links in the older compared to the younger children), with high confidence yielding a direct and positive effect on test performance and a direct and negative effect on adequate control behavior in the achievement test. Mastery-oriented motivation was not found to be substantially associated with monitoring (confidence), control (detection and correction of errors), or test performance underlining the importance of proximal, metacognitive factors for test performance in elementary school children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Colors have been found to affect psychological functioning. Empirical evidence suggests that, in test situations, brief perceptions of the color red or even the word "red" printed in black ink prime implicit anxious responses and consequently impair cognitive performance. However, we propose that this red effect depends on people's momentary capacity to exert control over their prepotent responses (i.e., self-control). In three experiments (Ns = 66, 78, and 130), first participants' self-control strength was manipulated. Participants were then primed with the color or word red versus gray prior to completing an arithmetic test or an intelligence test. As expected, self-control strength moderated the red effect. While red had a detrimental effect on performance of participants with depleted self-control strength (ego depletion), it did not affect performance of participants with intact self-control strength. We discuss implications of the present findings within the current debate on the robustness of priming results

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND A single non-invasive gene expression profiling (GEP) test (AlloMap®) is often used to discriminate if a heart transplant recipient is at a low risk of acute cellular rejection at time of testing. In a randomized trial, use of the test (a GEP score from 0-40) has been shown to be non-inferior to a routine endomyocardial biopsy for surveillance after heart transplantation in selected low-risk patients with respect to clinical outcomes. Recently, it was suggested that the within-patient variability of consecutive GEP scores may be used to independently predict future clinical events; however, future studies were recommended. Here we performed an analysis of an independent patient population to determine the prognostic utility of within-patient variability of GEP scores in predicting future clinical events. METHODS We defined the GEP score variability as the standard deviation of four GEP scores collected ≥315 days post-transplantation. Of the 737 patients from the Cardiac Allograft Rejection Gene Expression Observational (CARGO) II trial, 36 were assigned to the composite event group (death, re-transplantation or graft failure ≥315 days post-transplantation and within 3 years of the final GEP test) and 55 were assigned to the control group (non-event patients). In this case-controlled study, the performance of GEP score variability to predict future events was evaluated by the area under the receiver operator characteristics curve (AUC ROC). The negative predictive values (NPV) and positive predictive values (PPV) including 95 % confidence intervals (CI) of GEP score variability were calculated. RESULTS The estimated prevalence of events was 17 %. Events occurred at a median of 391 (inter-quartile range 376) days after the final GEP test. The GEP variability AUC ROC for the prediction of a composite event was 0.72 (95 % CI 0.6-0.8). The NPV for GEP score variability of 0.6 was 97 % (95 % CI 91.4-100.0); the PPV for GEP score variability of 1.5 was 35.4 % (95 % CI 13.5-75.8). CONCLUSION In heart transplant recipients, a GEP score variability may be used to predict the probability that a composite event will occur within 3 years after the last GEP score. TRIAL REGISTRATION Clinicaltrials.gov identifier NCT00761787.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Only few standardized apraxia scales are available and they do not cover all domains and semantic features of gesture production. Therefore, the objective of the present study was to evaluate the reliability and validity of a newly developed test of upper limb apraxia (TULIA), which is comprehensive and still short to administer. METHODS: The TULIA consists of 48 items including imitation and pantomime domain of non-symbolic (meaningless), intransitive (communicative) and transitive (tool related) gestures corresponding to 6 subtests. A 6-point scoring method (0-5) was used (score range 0-240). Performance was assessed by blinded raters based on videos in 133 stroke patients, 84 with left hemisphere damage (LHD) and 49 with right hemisphere damage (RHD), as well as 50 healthy subjects (HS). RESULTS: The clinimetric findings demonstrated mostly good to excellent internal consistency, inter- and intra-rater (test-retest) reliability, both at the level of the six subtests and at individual item level. Criterion validity was evaluated by confirming hypotheses based on the literature. Construct validity was demonstrated by a high correlation (r = 0.82) with the De Renzi-test. CONCLUSION: These results show that the TULIA is both a reliable and valid test to systematically assess gesture production. The test can be easily applied and is therefore useful for both research purposes and clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions, as well as to find appropriate cut-off values. METHODS: One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined, then either opened or not, after which their laser fluorescence was measured. Forty-three lesions were opened, the caries removed and the clinically identified caries depths were registered in addition to the radiographical scoring. Seventy-four sites were radiographically deemed sound or had enamel caries and were not opened. Here, the radiographical scorings were registered. RESULTS: Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D(0), n=40) showed significantly lower laser fluorescence measurements than carious sites (D(1-4), n=77) (Mann-Whitney test, P<0.025) suggesting a cut-off at 7 (sensitivity=0.68, specificity=0.7). Comparing measurements of D(0-2) (n=74) and D(3,4) (n=43), the results were also different by a statistically significant amount (P<0.025) and the cut-off calculated to be 16 (sensitivity=0.6, specificity=0.84). A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho=+0.47, P<0.01). Analysing the 43 opened lesions with their clinically found lesion depths as gold standard, there was a fair positive correlation to the laser fluorescence values (rho=+0.34, P=0.03) and a moderately strong correlation to the radiographic scoring (rho=+0.67, P<0.01). CONCLUSION: The device may be an adjunct tool in the approximal detection of caries along with established procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20°C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of the present work was to verify whether calculating a ratio between clotting times obtained with the sensitive PTT-LA and a less sensitive activated partial thromboplastin time (aPTT)-reagent may represent a valuable aPTT-based screening strategy for lupus anticoagulants (LA). Methods: For the pilot study, plasma samples from normal subjects (n = 15) and from patients with LA (n = 10), therapeutic anticoagulation with vitamin K-antagonists (VKA) (n = 15) or unfractionated heparin (n = 15), coagulation factors deficiency (n = 16), and inhibitory antibodies against factor VIII or IX (n = 11) were studied. For the evaluation study, 1553 consecutive plasma samples from nonanticoagulated patients investigated for LA between January 2005 and December 2007 at our institution were studied. Following screening strategies were employed: Pathromtin-SL (aPTT-SL), PTT-LA (aPTT-LA), ratio aPTT-LA/aPTT-SL (aPTT-ratio), and Russell's viper venom (RVV) based LA-Check. LA positive samples were identified by mixing studies and diluted RVV confirmation test (LA-Check/LA-Sure). Results: Pilot study: All screening strategies had a 100% sensitivity, and the aPTT-ratio reached the highest specificity (82%; 95%CI: 74-90%). Within the evaluation study, following sensitivities for LA screening were observed: aPTT-SL 59.0% (95%CI: 57-61%), aPTT-LA 82.1% (95%CI: 80-84%), aPTT-ratio 92.3% (95%CI: 91-94), and LA-Check 83.3% (95%CI: 82-85%). Conclusion: Calculating a ratio between the LA-sensitive PTT-LA and the less sensitive Pathromtin-SL improves the performance of the PTT-LA itself and represents a simple and sensitive aPTT-based integrated strategy for LA screening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Attempting to achieve the high diversity of training goals in modern competitive alpine skiing simultaneously can be difficult and may lead to compromised overall adaptation. Therefore, we investigated the effect of block training periodization on maximal oxygen consumption (VO2max) and parameters of exercise performance in elite junior alpine skiers. Six female and 15 male athletes were assigned to high-intensity interval (IT, N = 13) or control training groups (CT, N = 8). IT performed 15 high-intensity aerobic interval (HIT) sessions in 11 days. Sessions were 4 x 4 min at 90-95% of maximal heart rate separated by 3-min recovery periods. CT continued their conventionally mixed training, containing endurance and strength sessions. Before and 7 days after training, subjects performed a ramp incremental test followed by a high-intensity time-to-exhaustion (tlim) test both on a cycle ergometer, a 90-s high-box jump test as well as countermovement (CMJ) and squat jumps (SJ) on a force plate. IT significantly improved relative VO2max by 6.0% (P < 0.01; male +7.5%, female +2.1%), relative peak power output by 5.5% (P < 0.01) and power output at ventilatory threshold 2 by 9.6% (P < 0.01). No changes occurred for these measures in CT. tlim remained unchanged in both groups. High-box jump performance was significantly improved in males of IT only (4.9%, P < 0.05). Jump peak power (CMJ -4.8%, SJ -4.1%; P < 0.01), but not height decreased in IT only. For competitive alpine skiers, block periodization of HIT offers a promising way to efficiently improve VO2max and performance. Compromised explosive jump performance might be associated with persisting muscle fatigue.