245 resultados para nociceptive stimulation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To elicit and evaluate the NWR (nociceptive withdrawal reflex) in 2 and 11 day old foals, to investigate if buprenorphine causes antinociception and determine if the NWR response changes with increasing age. The effect of buprenorphine on behaviour was also evaluated. STUDY DESIGN Prospective, experimental cross-over trial. ANIMALS Nine Norwegian Fjord research foals. METHODS Buprenorphine, 10 μg kg(-1) was administered intramuscularly (IM) to the same foal at 2 days and at 11 days of age. The NWR and the effect of buprenorphine were evaluated by electromyograms recorded from the left deltoid muscle following electrical stimulation of the left lateral palmar nerve at the level of the pastern. Mentation, locomotor activity and respiratory rate were recorded before and after buprenorphine administration. RESULTS We were able to evoke the NWR and temporal summation in foals using this model. Buprenorphine decreased the root mean square amplitude following single electrical stimulation (p < 0.001) in both age groups, and increased the NWR threshold following single electrical stimulation in 2 day old foals (p = 0.0012). Repeated electrical stimulation at 2 Hz was more effective to elicit temporal summation compared to 5 Hz (p < 0.001). No effect of age upon the NWR threshold was found (p = 0.34). Sedation when left undisturbed (11 occasions), increased locomotor activity when handled (9 occasions) and tachypnea (13 occasions) were common side-effects of buprenorphine. CONCLUSION AND CLINICAL RELEVANCE These findings indicate that buprenorphine has antinociceptive effect in foals. Opioid side effects often recognized in adult horses also occur in foals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The nociceptive withdrawal reflex (NWR) model is used in animal pain research to quantify nociception. The aim of this study was to evaluate the NWR evoked by repeated stimulations in healthy, non-medicated standing sheep. Repeated electrical stimulations were applied at 5Hz for 2s to the digital nerves of the right thoracic and the pelvic limbs of 25 standing sheep. The stimulation intensities applied were fractions (0.5, 0.6, 0.7, 0.8, 0.9 and 1) of the individual previously determined nociceptive threshold (It) after single stimulation. Surface-electromyographic activity (EMG) was recorded from the deltoid, the femoral biceps or the peroneus tertius muscles. The repeated stimulation threshold (RS It) was reached if at least one stimulus in the train was followed by a reflex with a minimal root-mean-square-amplitude (RMSA) of 20μV. The behavioural reaction following each series of stimulations was scored on a scale from 0 (no reaction) to 5 (vigorous whole-body reaction). For the deltoid muscle, RS It was 2.3mA (1.6-3mA) with a reaction score of 2 (1-2) and at a fraction of 0.6 (0.5-0.8)×It. For the biceps femoris muscle, RS It was 2.9mA (2.6-4mA) with a reaction score of 1 (1-2) at a fraction of and 0.55 (0.4-0.7)×It while for the peroneus tertius muscle RS It was 3mA (2.8-3.5mA) with a reaction score of 1 (1-2) and at a fraction of 0.8 (0.8-0.95)×It. Both, RMSA and reaction scores increased significantly with increasing stimulation intensities in all muscles (p<0.001). The repeated application of electrical stimuli led to temporal summation of nociceptive inputs and therefore a reduction of the stimulus intensity evoking a withdrawal reaction in healthy, standing sheep. Data achieved in this study can now serve as reference for further clinical or experimental applications of the model in this species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the reliability of the conditioned pain modulation (CPM) paradigm assessed by an objective electrophysiological method, the nociceptive withdrawal reflex (NWR), and psychophysical measures, using hypothetical sample sizes for future studies as analytical goals. Thirty-four healthy volunteers participated in two identical experimental sessions, separated by 1 to 3 weeks. In each session, the cold pressor test (CPT) was used to induce CPM, and the NWR thresholds, electrical pain detection thresholds and pain intensity ratings after suprathreshold electrical stimulation were assessed before and during CPT. CPM was consistently detected by all methods, and the electrophysiological measures did not introduce additional variation to the assessment. In particular, 99% of the trials resulted in higher NWR thresholds during CPT, with an average increase of 3.4 mA (p<0.001). Similarly, 96% of the trials resulted in higher electrical pain detection thresholds during CPT, with an average increase of 2.2 mA (p<0.001). Pain intensity ratings after suprathreshold electrical stimulation were reduced during CPT in 84% of the trials, displaying an average decrease of 1.5 points in a numeric rating scale (p<0.001). Under these experimental conditions, CPM reliability was acceptable for all assessment methods in terms of sample sizes for potential experiments. The presented results are encouraging with regards to the use of the CPM as an assessment tool in experimental and clinical pain. Trial registration: Clinical Trials.gov NCT01636440.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypersensitivity of pain pathways is considered a relevant determinant of symptoms in chronic pain patients, but data on its prevalence are very limited. To our knowledge, no data on the prevalence of spinal nociceptive hypersensitivity are available. We studied the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity in 961 consecutive patients with various chronic pain conditions. Pain threshold and nociceptive withdrawal reflex threshold to electrical stimulation were used to assess pain hypersensitivity and spinal nociceptive hypersensitivity, respectively. Using 10th percentile cutoff of previously determined reference values, the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity (95% confidence interval) was 71.2 (68.3-74.0) and 80.0 (77.0-82.6), respectively. As a secondary aim, we analyzed demographic, psychosocial, and clinical characteristics as factors potentially associated with pain hypersensitivity and spinal nociceptive hypersensitivity using logistic regression models. Both hypersensitivity parameters were unaffected by most factors analyzed. Depression, catastrophizing, pain-related sleep interference, and average pain intensity were significantly associated with hypersensitivity. However, none of them was significant for both unadjusted and adjusted analyses. Furthermore, the odds ratios were very low, indicating modest quantitative impact. To our knowledge, this is the largest prevalence study on central hypersensitivity and the first one on the prevalence of spinal nociceptive hypersensitivity in chronic pain patients. The results revealed an impressively high prevalence, supporting a high clinical relevance of this phenomenon. Electrical pain thresholds and nociceptive withdrawal reflex explore aspects of pain processing that are mostly independent of sociodemographic, psychological, and clinical pain-related characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HP802-247 is a new-generation, allogeneic tissue engineering product consisting of growth-arrested, human keratinocytes (K) and fibroblasts (F) delivered in a fibrin matrix by a spray device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The noxious stimulation response index (NSRI) is a novel anesthetic depth index ranging between 100 and 0, computed from hypnotic and opioid effect-site concentrations using a hierarchical interaction model. The authors validated the NSRI on previously published data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The primary aim of the present study was to investigate whether there is a relationship between central hypersensitivity (assessed by pressure pain thresholds of uninjured tissues) and intradiscal pain threshold during discography. The secondary aim was to test the hypothesis that peripheral noxious stimulation dynamically modulates central hypersensitivity. PATIENTS: Twenty-four patients with positive provocation discography were tested for central hypersensitivity by pressure algometry before and after the intervention with assessments of pressure pain detection and tolerance thresholds. Intradiscal pain threshold was assessed by measuring intradiscal pressure at the moment of pain provocation during discography. Correlation analyses between intradiscal pain threshold and pressure algometry were made. For the secondary aim, pressure algometry data before and after discography were compared. RESULTS: Significant correlation with intradiscal pain threshold was found for pressure pain detection threshold at the toe (regression coefficient: 0.03, P = 0.05) and pressure pain tolerance thresholds at the nonpainful point at the back (0.02, P = 0.024). Tolerance threshold at the toe was a significant predictor for intradiscal pain threshold only in multiple linear regression (0.036, P = 0.027). Detection as well as tolerance thresholds significantly decreased after discography at the painful and the nonpainful point at the back, but not at the toe. CONCLUSIONS: Central hypersensitivity may influence intradiscal pain threshold, but with a modest quantitative impact. The diagnostic value of provocation discography is therefore not substantially impaired. Regional, but not generalized central hypersensitivity is dynamically modulated by ongoing peripheral nociceptive input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Articular cartilage injuries and degeneration affect a large proportion of the population in developed countries world wide. Stem cells can be differentiated into chondrocytes by adding transforming growth factor-beta1 and dexamethasone to a pellet culture, which are unfeasible for tissue engineering purposes. We attempted to achieve stable chondrogenesis without any requirement for exogenous growth factors. Human mesenchymal stem cells were transduced with an adenoviral vector containing the SRY-related HMG-box gene 9 (SOX9), and were cultured in a three-dimensional (3D) hydrogel scaffold composite. As an additional treatment, mechanical stimulation was applied in a custom-made bioreactor. SOX9 increased the expression level of its known target genes, as well as its cofactors: the long form of SOX5 and SOX6. However, it was unable to increase the synthesis of sulfated glycosaminoglycans (GAGs). Mechanical stimulation slightly enhanced collagen type X and increased lubricin expression. The combination of SOX9 and mechanical load boosted GAG synthesis as shown by (35)S incorporation. GAG production rate corresponded well with the amount of (endogenous) transforming growth factor-beta1. Finally, cartilage oligomeric matrix protein expression was increased by both treatments. These findings provide insight into the mechanotransduction of mesenchymal stem cells and demonstrate the potential of a transcription factor in stem cell therapy.