69 resultados para multi-way analysis


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The link between the atmospheric CO2 level and the ventilation state of the deep ocean is an important building block of the key hypotheses put forth to explain glacial-interglacial CO2 fluctuations. In this study, we systematically examine the sensitivity of atmospheric CO2 and its carbon isotope composition to changes in deep ocean ventilation, the ocean carbon pumps, and sediment formation in a global 3-D ocean-sediment carbon cycle model. Our results provide support for the hypothesis that a break up of Southern Ocean stratification and invigorated deep ocean ventilation were the dominant drivers for the early deglacial CO2 rise of ~35 ppm between the Last Glacial Maximum and 14.6 ka BP. Another rise of 10 ppm until the end of the Holocene is attributed to carbonate compensation responding to the early deglacial change in ocean circulation. Our reasoning is based on a multi-proxy analysis which indicates that an acceleration of deep ocean ventilation during early deglaciation is not only consistent with recorded atmospheric CO2 but also with the reconstructed opal sedimentation peak in the Southern Ocean at around 16 ka BP, the record of atmospheric δ13CCO2, and the reconstructed changes in the Pacific CaCO3 saturation horizon.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate and compare long-term functional outcome after partial carpal arthrodesis and pancarpal arthrodesis in dogs using kinetic gait analysis. METHODS: Fourteen dogs with 19 partial carpal or pancarpal arthrodeses were retrospectively examined and underwent force-plate gait analysis. Mean times since surgery were 29.4 and 24.4 months for pancarpal and partial carpal arthrodesis respectively. Vertical and braking-propulsive ground reaction force profiles were compared between treatment groups, and to those of normal dogs (control group) using Kruskal-Wallis one-way analysis of variance. RESULTS: With the exception of time to vertical peak that occurred earlier in dogs with pancarpal than in dogs with partial carpal arthrodesis (p <0.01), there was no difference between the two treatment groups. Several parameters differed significantly between operated and healthy dogs (p <0.01): vertical impulses were significantly lower in both treatment groups, braking forces and impulses were also reduced after both techniques. Propulsive forces and impulses were only reduced in dogs with pancarpal arthrodesis. When comparing gait parameters of sound limbs of unilateral operated dogs to those of control dogs, braking forces and impulses (p <0.01; p <0.05) were significantly higher in the sound legs of unilateral operated dogs. CLINICAL SIGNIFICANCE: Long-term outcome after partial carpal and pancarpal arthrodesis is good and comparable to each other. Propulsive action may be altered more in dogs with pancarpal arthrodesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study is to assess the structural and cross-cultural validity of the KIDSCREEN-27 questionnaire. METHODS: The 27-item version of the KIDSCREEN instrument was derived from a longer 52-item version and was administered to young people aged 8-18 years in 13 European countries in a cross-sectional survey. Structural and cross-cultural validity were tested using multitrait multi-item analysis, exploratory and confirmatory factor analysis, and Rasch analyses. Zumbo's logistic regression method was applied to assess differential item functioning (DIF) across countries. Reliability was assessed using Cronbach's alpha. RESULTS: Responses were obtained from n = 22,827 respondents (response rate 68.9%). For the combined sample from all countries, exploratory factor analysis with procrustean rotations revealed a five-factor structure which explained 56.9% of the variance. Confirmatory factor analysis indicated an acceptable model fit (RMSEA = 0.068, CFI = 0.960). The unidimensionality of all dimensions was confirmed (INFIT: 0.81-1.15). Differential item functioning (DIF) results across the 13 countries showed that 5 items presented uniform DIF whereas 10 displayed non-uniform DIF. Reliability was acceptable (Cronbach's alpha = 0.78-0.84 for individual dimensions). CONCLUSIONS: There was substantial evidence for the cross-cultural equivalence of the KIDSCREEN-27 across the countries studied and the factor structure was highly replicable in individual countries. Further research is needed to correct scores based on DIF results. The KIDSCREEN-27 is a new short and promising tool for use in clinical and epidemiological studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: AuTi alloys with 1.6% to 1.7% (wt%) Ti provide sufficient bond strength to veneering ceramics, but the strength of entire metal-ceramic restorations fabricated from these alloys is not known. However, this information is important to assess the clinical performance of such materials. PURPOSE: This in vitro study evaluated the fracture strength and thermal shock resistance of metal-ceramic crowns with AuTi frameworks produced by milling or casting. MATERIAL AND METHODS: Frameworks of the alloy Au-1.7Ti-0.1Ir (wt%) (Esteticor Vision) were produced by milling or casting (test groups). A high-gold alloy (Esteticor Special) was used as the control. The frameworks were veneered with ceramic (VMK 95). Specimens (n=7) were loaded until fracture. Loads at failure (N) were recorded and the mean values statistically evaluated using 1-way analysis of variance and a post hoc Dunnett test (alpha=.05). To assess the crazing resistance of the veneering ceramic, 6 additional crowns of each group were subjected to a thermal shock test. Fractured surfaces were documented by scanning electron microscopy. Coefficients of thermal expansion of the materials used were measured (n=2) to assess the thermal compatibility between alloys and ceramic. RESULTS: The mean fracture strength of the crowns with machined AuTi frameworks (1294 +/- 236 N) was significantly lower (P=.012) than that of the cast AuTi frameworks (1680 +/- 150 N), but statistically not different than the high-gold alloy (1449 +/- 159 N). Bonding failure to the AuTi alloy predominantly occurred at the alloy-oxide interface. For the high-gold alloy, more ceramic residues were observed. In the thermal shock test, crowns with milled AuTi frameworks showed significantly higher thermal shock resistance compared to the other groups. The coefficients of thermal expansion (Esteticor Vision cast: 14.5 microm/m.K; Esteticor Vision milled: 14.3 microm/m.K; Esteticor Special cast: 13.7 microm/m.K) did not correlate with the results of the thermal shock test. CONCLUSION: The in vitro fracture strength of crowns with milled AuTi frameworks is lower than that obtained with cast AuTi frameworks, but comparable to those crowns produced with a high-gold alloy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To prospectively compare cartilage T2 values after microfracture therapy (MFX) and matrix-associated autologous chondrocyte transplantation (MACT) repair procedures. MATERIALS AND METHODS: The study had institutional review board approval by the ethics committee of the Medical University of Vienna; informed consent was obtained. Twenty patients who underwent MFX or MACT (10 in each group) were enrolled. For comparability, patients of each group were matched by mean age (MFX, 40.0 years +/- 15.4 [standard deviation]; MACT, 41.0 years +/- 8.9) and postoperative interval (MFX, 28.6 months +/- 5.2; MACT, 27.4 months +/- 13.1). Magnetic resonance (MR) imaging was performed with a 3-T MR imager, and T2 maps were calculated from a multiecho spin-echo measurement. Global, as well as zonal, quantitative T2 values were calculated within the cartilage repair area and within cartilage sites determined to be morphologically normal articular cartilage. Additionally, with consideration of the zonal organization, global regions of interest were subdivided into deep and superficial areas. Differences between cartilage sites and groups were calculated by using a three-way analysis of variance. RESULTS: Quantitative T2 assessment of normal native hyaline cartilage showed similar results for all patients and a significant trend of increasing T2 values from deep to superficial zones (P < .05). In cartilage repair areas after MFX, global mean T2 was significantly reduced (P < .05), whereas after MACT, mean T2 was not reduced (P > or = .05). For zonal variation, repair tissue after MFX showed no significant trend between different depths (P > or = .05), in contrast to repair tissue after MACT, in which a significant increase from deep to superficial zones (P < .05) could be observed. CONCLUSION: Quantitative T2 mapping seems to reflect differences in repair tissues formed after two surgical cartilage repair procedures. (c) RSNA, 2008.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to evaluate the bonding of glass ionomer cements (GICs) to sound and caries-affected dentin by microtensile bond strength (μTBS) and nanoleakage (NL) tests. METHODS Occlusal cavity preparations were made in 36 sound primary molars. Half of the specimens were submitted to a pH-cycling model to create simulated caries-affected dentin. Teeth were randomly restored with one of the three materials: (1) resin-modified GIC with nanoparticles (Ketac N100; KN); (2) resin-modified GIC (Vitremer; VI); and (3) high-viscosity GIC (Ketac Molar Easy Mix; KM). Specimens were tested using a microtensile test (1 mm/minute). One specimen from each tooth was immersed in ammoniacal silver nitrate for 24 hours and revealed after eight hours to assess interfacial NL. The μTBS means were analyzed by 2-way analysis of variance and Tukey's post hoc test. For NL, Kruskal-Wallis and Mann-Whitney tests were used (P<.05). RESULTS No difference was found between sound and caries-affected dentin (P>.05). KM showed the lowest GIC-dentin μTBS values, while VI and KN showed higher values. Infiltration of ammoniacal silver nitrate into the adhesive interface was not affected by sound or caries-affected dentin. CONCLUSION Caries-affected dentin does not jeopardize the bonding of glass ionomer cements to primary tooth dentin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

SUMMARY A recent systematic review demonstrated that, overall, orthodontic treatment might result in a small worsening of periodontal status. The aim of this retrospective study was to test the hypothesis that a change of mandibular incisor inclination promotes development of labial gingival recessions. One hundred and seventy-nine subjects who met the following inclusion criteria were selected: age 11-14 years at start of orthodontic treatment (TS), bonded retainer placed immediately after treatment (T₀), dental casts and lateral cephalograms available pre-treatment (TS), post-treatment (T₀), 2 years post-treatment (T₂), and 5 years post-treatment (T₅). Depending on the change of lower incisor inclination during treatment (ΔInc_Incl), the sample was divided into three groups: Retro (N = 34; ΔInc_Incl ≤ -1 degree), Stable (N = 22; ΔInc_Incl > -1 degree and ≤1 degree), and Pro (N = 123; ΔInc_Incl > 1 degree). Clinical crown heights of mandibular incisors and the presence of gingival recessions in this region were assessed on plaster models. Fisher's exact tests, one-way analysis of variance, and regression models were used for analysis of inter-group differences. The mean increase of clinical crown heights (T₀ to T₅) of mandibular incisors ranged from 0.6 to 0.91 mm in the Retro, Stable, and Pro groups, respectively; the difference was not significant (P = 0.534). At T₅, gingival recessions were present in 8.8, 4.5, and 16.3 per cent patients from the Retro, Stable, and Pro groups, respectively. The difference was not significant (P = 0.265). The change of lower incisors inclination during treatment did not affect development of labial gingival recessions in this patient group.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To biomechanically test the properties of three different Universal Micro External Fixator (UMEX™) configurations with regard to their use in very small animals (<5kg) and compare the UMEX system to the widely used IMEX External Skeletal Fixation (SK™) system in terms of stiffness, space needed for pin placement and weight. METHODS Three different UMEX configurations (type Ia, type Ib, and type II modified) and one SK configuration type Ia were used to stabilize Delrin plastic rods in a 1 cm fracture gap model. These constructs were tested in axial compression, craniocaudal bending, mediolateral bending, and torsion. Testing was conducted within the elastic range and mean stiffness in each mode was determined from the slope of the linear portion of the load-deformation curve. A Kruskal Wallis one-way analysis of variance on ranks test was utilized to assess differences between constructs (p <0.05). RESULTS The UMEX type II modified configuration was significantly stiffer than the other UMEX configurations and the SK type Ia, except in craniocaudal bending, where the SK type Ia configuration was stiffer than all UMEX constructs. The UMEX type Ia configuration was significantly the weakest of those frames. The UMEX constructs were lighter and smaller than the SK, thus facilitating closer pin placement. CONCLUSIONS Results supported previous reports concerning the superiority of more complex constructs regarding stiffness. The UMEX system appears to be a valid alternative for the treatment of long-bone fractures in very small animals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Obesity is a growing problem in western societies. The aim of this retrospective cohort study was to determine the association between the overweight and obese polytrauma patients and pneumonia after injury. METHODS A total of 628 patients with an Injury Severity Score (ISS) of 16 or greater and 16 years or older were included in this retrospective study. The sample was subdivided into three groups as follows: body mass index (BMI) of less than 25 kg/m2; BMI of 25 kg/m2 to 30 kg/m2; and BMI more than 30 kg/m2. The Murray score was assessed at admission and at its maximum during hospitalization to determine pulmonary problems. Pneumonia was defined as bacteriologically positive sputum with appropriate radiologic and laboratory changes (C-reactive protein and interleukin 6). Data are given as mean ± SEM. One-way analysis of variance and the Kruskal-Wallis test were used for the analyses, and the significance level was set at p < 0.05; Bonferroni-Dunn test was performed as post hoc analysis. RESULTS The Abbreviated Injury Scale (AIS) score for the thorax was 3.2 ± 0.1 in the group with a BMI of less than 25 kg/m2, 3.3 ± 0.1 in the group with a BMI of 25 kg/m2 to 30 kg/m2, and 2.8 ± 0.2 in the group with BMI of more than 30 kg/m2 (p = 0.044). The Murray score at admission was elevated with increasing BMI (0.8 ± 0.8 for BMI < 25 kg/m2, 0.9 ± 0.9 for BMI 25–30 kg/m2, and 1.0 ± 0.8 for BMI > 30 kg/m2; p = 0.137); the maximum Murray score during hospitalization revealed significant differences (1.2 ± 0.9 for BMI < 25 kg/m2, 1.6 ± 1.0 for BMI 25–30 kg/m2, and 1.5 ± 0.9 for BMI > 30 kg/m2; p < 0.001). The incidence of pneumonia also increased with increasing BMI (1.6% for BMI < 25 kg/m2, 2.0% for BMI 25–30 kg/m2, and 3.1% for BMI > 30 kg/m2; p = 0.044). CONCLUSION Obesity leads to an increased incidence of pneumonia in a polytrauma situation. LEVEL OF EVIDENCE Prognostic/epidemiologic study, level IV.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Obesity is a growing problem in industrial nations. The aim of this study was to determine the relationship between the body mass index (BMI) and the pattern of injury after polytrauma. Methods: This retrospective study included 651 patients with an injury severity score (ISS) ≥16 and aged ≥16 years who were subdivided into three groups: BMI < 25 kg/m2, BMI 25–30 kg/m2, and BMI > 30 kg/m2. The Abbreviated Injury Scale (AIS) was used to quantify the injuries in the different anatomical regions. The Murray score was assessed at admission and at its maximum during hospitalization to evaluate pulmonary problems. Data are presented as means ± standard errors of the means. One way analysis of variance, χ2 test and Kruskal-Wallis test were used for the analyses and the significance level was set at p < 0.05. Results: The AIS of the thorax was 3.2 ± 0.1 in the BMI < 25 kg/m2 group, 3.3 ± 0.1 in the BMI 25–30 kg/m2 group, and 2.8 ± 0.2 in the BMI > 30 kg/m2 group; p < 0.05. The Murray score at admission increased significantly with increasing BMI (0.8 ± 0.8 for BMI < 25 kg/m2, 0.9 ± 0.9 for BMI 25–30 kg/m2, and 1.0 ± 0.8 for BMI > 30 kg/m2; p < 0.05) as was the maximum Murray score during hospitalization (1.2 ± 0.9 for BMI < 25 kg/m2, 1.6 ± 1.0 for BMI 25–30 kg/m2, and 1.5 ± 0.9 for BMI > 30 kg/m2; p < 0.001). The number of ventilator days was also elevated significantly with increasing BMI (5.9 ± 0.4 for BMI < 25 kg/m2, 7.7 ± 0.8 for BMI 25–30 kg/m2, and 7.9 ± 1.6 for BMI > 30 kg/m2; p < 0.05). Conclusion: Overweight and obesity lead to a higher incidence of thoracic trauma in a polytrauma situation and may additionally handicap ventilation in an obstructive manner.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To determine whether diffusion-weighted (DW) magnetic resonance (MR) imaging in living renal allograft donation allows monitoring of potential changes in the nontransplanted remaining kidney of the donor because of unilateral nephrectomy and changes in the transplanted kidney before and after transplantation in donor and recipient, respectively, and whether DW MR parameters are correlated in the same kidney before and after transplantation. Materials and Methods The study protocol was approved by the local ethics committee; written informed consent was obtained. Thirteen healthy kidney donors and their corresponding recipients prospectively underwent DW MR imaging (multiple b values) in donors before donation and in donors and recipients at day 8 and months 3 and 12 after donation. Total apparent diffusion coefficient (ADCT) values were determined; contribution of microcirculation was quantified in perfusion fraction (FP). Longitudinal changes of diffusion parameters were compared (repeated-measures one-way analysis of variance with post hoc pairwise comparisons). Correlations were tested (linear regression). Results ADCT values in nontransplanted kidney of donors increased from a preexplantation value of (188 ± 9 [standard deviation]) to (202 ± 11) × 10(-5) mm(2)/sec in medulla and from (199 ± 11) to (210 ± 13) × 10(-5) mm(2)/sec in cortex 1 week after donation (P < .004). Medullary, but not cortical, ADCT values stayed increased up to 1 year. ADCT values in allografts in recipients were stable. Compared with values obtained before transplantation in donors, the corticomedullary difference was reduced in allografts (P < .03). Cortical ADCT values correlated with estimated glomerular filtration rate in recipients (R = 0.56, P < .001) but not donors. Cortical ADCT values in the same kidney before transplantation in donors correlated with those in recipients on day 8 after transplantation (R = 0.77, P = .006). FP did not show significant changes. Conclusion DW MR imaging depicts early adaptations in the remaining nontransplanted kidney of donors after nephrectomy. All diffusion parameters remained constant in allograft recipients after transplantation. This method has potential monitoring utility, although assessment of clinical relevance is needed. © RSNA, 2013 Online supplemental material is available for this article.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Volunteering rates in Switzerland vary substantially across language regions. In this article, we investigate the cultural roots of this variation by presenting and empirically testing two different conceptualizations of how linguistic culture is related to individual volunteering. Whereas the first perspective perceives the individual as belonging to a particular language community and its norms and values as crucial for individual volunteering, the other sees the linguistic culture mainly as an important context in which an individual lives and which therefore influences individual volunteering. Empirically, we base our analysis on new survey data from 60 Swiss communes and apply a Bayesian multi-level analysis in order to disentangle the linguistic group from contextual effects. Our analysis supports the view that cultural patterns of civic self-organization can indeed explain regional volunteering behaviour in Switzerland. Whereas the propensity to volunteer is generally highest in German-speaking Switzerland, our findings reveal that it is the group of French speakers that exhibits the highest propensity to volunteer when controlling for language region.