21 resultados para low threshold pumping
Resumo:
BACKGROUND: In women with chronic anovulation, the choice of the FSH starting dose and the modality of subsequent dose adjustments are critical in controlling the risk of overstimulation. The aim of this prospective randomized study was to assess the efficacy and safety of a decremental FSH dose regimen applied once the leading follicle was 10-13 mm in diameter in women treated for WHO Group II anovulation according to a chronic low-dose (CLD; 75 IU FSH for 14 days with 37.5 IU increment) step-up protocol. METHODS: Two hundred and nine subfertile women were treated with recombinant human FSH (r-hFSH) (Gonal-f) for ovulation induction according to a CLD step-up regimen. When the leading follicle reached a diameter of 10-13 mm, 158 participants were randomized by means of a computer-generated list to receive either the same FSH dose required to achieve the threshold for follicular development (CLD regimen) or half of this FSH dose [sequential (SQ) regimen]. HCG was administered only if not more than three follicles >or=16 mm in diameter were present and/or serum estradiol (E(2)) values were <1200 pg/ml. The primary outcome measure was the number of follicles >or=16 mm in size at the time of hCG administration. RESULTS: Clinical characteristics and ovarian parameters at the time of randomization were similar in the two groups. Both CLD and SQ protocols achieved similar follicular growth as regards the total number of follicles and medium-sized or mature follicles (>/=16 mm: 1.5 +/- 0.9 versus 1.4 +/- 0.7, respectively). Furthermore, serum E(2) levels were equivalent in the two groups at the time of hCG administration (441 +/- 360 versus 425 +/- 480 pg/ml for CLD and SQ protocols, respectively). The rate of mono-follicular development was identical as well as the percentage of patients who ovulated and achieved pregnancy. CONCLUSIONS: The results show that the CLD step-up regimen for FSH administration is efficacious and safe for promoting mono-follicular ovulation in women with WHO Group II anovulation. This study confirms that maintaining the same FSH starting dose for 14 days before increasing the dose in step-up regimen is critical to adequately control the risk of over-response. Strict application of CLD regimen should be recommended in women with WHO Group II anovulation.
Resumo:
OBJECTIVES: To investigate the modulation of the nociceptive withdrawal reflex (NWR) and temporal summation (TS) by low-dose acepromazine (ACP) in conscious dogs. To assess the short- and long-term stability of the reflex thresholds. STUDY DESIGN: Randomized, blinded, placebo-controlled cross-over experimental study. ANIMALS: Eight adult male Beagles. METHODS: The NWR was elicited using single transcutaneous electrical stimulation of the ulnar nerve. Repeated stimuli (10 pulses, 5 Hz) were applied to evoke TS. The responses of the deltoideus muscle were recorded and quantified by surface electromyography and the behavioural reactions were scored. Each dog received 0.01 mg kg(-1) ACP or an equal volume saline intravenously (IV) at 1 week intervals. Measurements were performed before (baseline) and 20, 60 and 100 minutes after drug administration. Sedation was scored before drug administration and then at 10 minutes intervals. Data were analyzed with Friedman repeated measures analysis of variance on ranks and Wilcoxon signed rank tests. RESULTS: Acepromazine resulted in a mild tranquilization becoming obvious at 20 minutes and peaking 30 minutes after injection. Single (I(t)) and repeated stimuli (TS(t)) threshold intensities, NWR and TS characteristics and behavioural responses were not affected by the ACP at any time point. Both I(t) and TS(t) were stable over time. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, 0.01 mg kg(-1) ACP IV had no modulatory action on the NWR evoked by single or repeated stimuli, suggesting no antinociceptive activity on phasic nociceptive stimuli. The evidence of the stability of the NWR thresholds supports the use of the model as an objective tool to investigate nociception in conscious dogs. A low dose of ACP administered as the sole drug, can be used to facilitate the recordings in anxious subjects without altering the validity of this model.
Resumo:
We obtain the next-to-next-to-leading order corrections to transverse-momentum spectra of W, Z and Higgs bosons near the partonic threshold. In the threshold limit, the electroweak boson recoils against a low-mass jet and all radiation is either soft, or collinear to the jet or the beam directions. We extract the virtual corrections from known results for the relevant two-loop four-point amplitudes and combine them with the soft and collinear two-loop functions as defined in Soft-Collinear Effective Theory. We have implemented these results in a public code PeTeR and present numerical results for the threshold resummed cross section of W and Z bosons at next-to-next-to-next-to-leading logarithmic accuracy, matched to next-to-leading fixed-order perturbation theory. The two-loop corrections lead to a moderate increase in the cross section and reduce the scale uncertainty by about a factor of two. The corrections are significantly larger for Higgs production.
Resumo:
Degeneration of the intervertebral disc, sometimes associated with low back pain and abnormal spinal motions, represents a major health issue with high costs. A non-invasive degeneration assessment via qualitative or quantitative MRI (magnetic resonance imaging) is possible, yet, no relation between mechanical properties and T2 maps of the intervertebral disc (IVD) has been considered, albeit T2 relaxation time values quantify the degree of degeneration. Therefore, MRI scans and mechanical tests were performed on 14 human lumbar intervertebral segments freed from posterior elements and all soft tissues excluding the IVD. Degeneration was evaluated in each specimen using morphological criteria, qualitative T2 weighted images and quantitative axial T2 map data and stiffness was calculated from the load-deflection curves of in vitro compression, torsion, lateral bending and flexion/extension tests. In addition to mean T2, the OTSU threshold of T2 (TOTSU), a robust and automatic histogram-based method that computes the optimal threshold maximizing the distinction of two classes of values, was calculated for anterior, posterior, left and right regions of each annulus fibrosus (AF). While mean T2 and degeneration schemes were not related to the IVDs' mechanical properties, TOTSU computed in the posterior AF correlated significantly with those classifications as well as with all stiffness values. TOTSU should therefore be included in future degeneration grading schemes.
Resumo:
OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.
Resumo:
BACKGROUND AND OBJECTIVES Reliability is an essential condition for using quantitative sensory tests (QSTs) in research and clinical practice, but information on reliability in patients with chronic pain is sparse. The aim of this study was to evaluate the reliability of different QST in patients with chronic low back pain. METHODS Eighty-nine patients with chronic low back pain participated in 2 identical experimental sessions, separated by at least 7 days. The following parameters were recorded: pressure pain detection and tolerance thresholds at the toe, electrical pain thresholds to single and repeated stimulation, heat pain detection and tolerance thresholds at the arm and leg, cold pain detection threshold at the arm and leg, and conditioned pain modulation using the cold pressor test.Reliability was analyzed using the coefficient of variation, the coefficient of repeatability, and the intraclass correlation coefficient. It was judged as acceptable or not based primarily on the analysis of the coefficient of repeatability. RESULTS The reliability of most tests was acceptable. Exceptions were cold pain detection thresholds at the leg and arm. CONCLUSIONS Most QST measurements have acceptable reliability in patients with chronic low back pain.