45 resultados para inflation bousière
Resumo:
Observable quantities in cosmology are dimensionless, and therefore independent of the units in which they are measured. This is true of all physical quantities associated with the primordial perturbations that source cosmic microwave background anisotropies such as their amplitude and spectral properties. However, if one were to try and infer an absolute energy scale for inflation—a priori, one of the more immediate corollaries of detecting primordial tensor modes—one necessarily makes reference to a particular choice of units, the natural choice for which is Planck units. In this note, we discuss various aspects of how inferring the energy scale of inflation is complicated by the fact that the effective strength of gravity as seen by inflationary quanta necessarily differs from that seen by gravitational experiments at presently accessible scales. The uncertainty in the former relative to the latter has to do with the unknown spectrum of universally coupled particles between laboratory scales and the putative scale of inflation. These intermediate particles could be in hidden as well as visible sectors or could also be associated with Kaluza–Klein resonances associated with a compactification scale below the scale of inflation. We discuss various implications for cosmological observables.
Resumo:
Lung recruitment maneuvers (RMs), used to reopen atelectatic lung units and to improve oxygenation during mechanical ventilation, may result in hemodynamic impairment. We hypothesize that pulmonary arterial hypertension aggravates the consequences of RMs in the splanchnic circulation. Twelve anesthetized pigs underwent laparotomy and prolonged postoperative ventilation. Systemic, regional, and organ blood flows were monitored. After 6 h (= baseline), a recruitment maneuver was performed with sustained inflation of the lungs. Thereafter, the pigs were randomly assigned to group C (control, n = 6) or group E with endotoxin-induced pulmonary arterial hypertension (n = 6). Endotoxemia resulted in a normotensive and hyperdynamic state and a deterioration of the oxygenation index by 33%. The RM was then repeated in both groups. Pulmonary artery pressure increased during lipopolysaccharide infusion from 17 ± 2 mmHg (mean ± SD) to 31 ± 10 mmHg and remained unchanged in controls (P < 0.05). During endotoxemia, RM decreased aortic pulse pressure from 37 ± 14 mmHg to 27 ± 13 mmHg (mean ± SD, P = 0.024). The blood flows of the renal artery, hepatic artery, celiac trunk, superior mesenteric artery, and portal vein decreased to 71% ± 21%, 69% ± 20%, 76% ± 16%, 79% ± 18%, and 81% ± 12%, respectively, of baseline flows before RM (P < 0.05 all). Organ perfusion of kidney cortex, kidney medulla, liver, and jejunal mucosa in group E decreased to 65% ± 19%, 77% ± 13%, 66% ± 26%, and 71% ± 12%, respectively, of baseline flows (P < 0.05 all). The corresponding recovery to at least 90% of baseline regional blood flow and organ perfusion lasted 1 to 5 min. Importantly, the decreases in regional blood flows and organ perfusion and the time to recovery of these flows did not differ from the controls. In conclusion, lipopolysaccharide-induced pulmonary arterial hypertension does not aggravate the RM-induced significant but short-lasting decreases in systemic, regional, and organ blood flows.
Resumo:
The optical characteristics of the human cornea depends on the mechanical balance between the intra-ocular pressure and intrinsic tissue stiffness. A wide range of ophthalmic surgical procedures alter corneal biomechanics to induce local or global curvature changes for the correction of visual acuity. Due to the large number of surgical interventions performed every day, a deeper understanding of corneal biomechanics is needed to improve the safety of these procedures and medical devices. The aim of this study is to propose a biomechanical model of the human cornea, based on stromal microstructure. The constitutive mechanical law includes collagen fiber distribution based on X-ray scattering analysis, collagen cross-linking, and fiber uncrimping. Our results showed that the proposed model reproduced inflation and extensiometry experimental data [Elsheikh et al., Curr. Eye Res., 2007; Elsheikh et al., Exp. Eye Res., 2008] successfully. The mechanical properties obtained for different age groups demonstrated an increase in collagen cross-linking for older specimens. In future work such a model could be used to simulate non-symmetric interventions, and provide better surgical planning.
Resumo:
The optical quality of the human eye mainly depends on the refractive performance of the cornea. The shape of the cornea is a mechanical balance between intraocular pressure and tissue intrinsic stiffness. Several surgical procedures in ophthalmology alter the biomechanics of the cornea to provoke local or global curvature changes for vision correction. Legitimated by the large number of surgical interventions performed every day, the demand for a deeper understanding of corneal biomechanics is rising to improve the safety of procedures and medical devices. The aim of our work is to propose a numerical model of corneal biomechanics, based on the stromal microstructure. Our novel anisotropic constitutive material law features a probabilistic weighting approach to model collagen fiber distribution as observed on human cornea by Xray scattering analysis (Aghamohammadzadeh et. al., Structure, February 2004). Furthermore, collagen cross-linking was explicitly included in the strain energy function. Results showed that the proposed model is able to successfully reproduce both inflation and extensiometry experimental data (Elsheikh et. al., Curr Eye Res, 2007; Elsheikh et. al., Exp Eye Res, May 2008). In addition, the mechanical properties calculated for patients of different age groups (Group A: 65-79 years; Group B: 80-95 years) demonstrate an increased collagen cross-linking, and a decrease in collagen fiber elasticity from younger to older specimen. These findings correspond to what is known about maturing fibrous biological tissue. Since the presented model can handle different loading situations and includes the anisotropic distribution of collagen fibers, it has the potential to simulate clinical procedures involving nonsymmetrical tissue interventions. In the future, such mechanical model can be used to improve surgical planning and the design of next generation ophthalmic devices.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
Recently, a clinical study on patients with stable coronary artery disease (CAD) showed that external counterpulsation therapy (ECP) at high (300 mmHg) but not at low inflation pressure (80 mmHg) promoted coronary collateral growth, most likely due to shear stress-induced arteriogenesis. The exact molecular mechanisms behind shear stress-induced arteriogenesis are still obscure. We therefore characterized plasma levels of circulating microparticles (MPs) from these CAD patients because of their ambivalent nature as a known cardiovascular risk factor and as a promoter of neovascularization in the case of platelet-derived MPs. MPs positive for Annexin V and CD31CD41 were increased, albeit statistically significant (P<0.05, vs. baseline) only in patients receiving high inflation pressure ECP as determined by flow cytometry. MPs positive for CD62E, CD146, and CD14 were unaffected. In high, but not in low, inflation pressure treatment, change of CD31CD41 was inversely correlated to the change in collateral flow index (CFI), a measure for collateral growth. MPs from the high inflation pressure group had a more sustained pro-angiogenic effect than the ones from the low inflation pressure group, with the exception of one patient showing also an increased CFI after treatment. A total of 1005 proteins were identified by a label-free proteomics approach from MPs of three patients of each group applying stringent acceptance criteria. Based on semi-quantitative protein abundance measurements, MPs after ECP therapy contained more cellular proteins and increased CD31, corroborating the increase in MPs. Furthermore, we show that MP-associated factors of the innate immune system were decreased, many membrane-associated signaling proteins, and the known arteriogenesis stimulating protein transforming growth factor beta-1 were increased after ECP therapy. In conclusion, our data show that ECP therapy increases platelet-derived MPs in patients with CAD and that the change in protein cargo of MPs is likely in favor of a pro angiogenic/arteriogenic property.
Resumo:
Anaesthesia causes a respiratory impairment, whether the patient is breathing spontaneously or is ventilated mechanically. This impairment impedes the matching of alveolar ventilation and perfusion and thus the oxygenation of arterial blood. A triggering factor is loss of muscle tone that causes a fall in the resting lung volume, functional residual capacity. This fall promotes airway closure and gas adsorption, leading eventually to alveolar collapse, that is, atelectasis. The higher the oxygen concentration, the faster will the gas be adsorbed and the aleveoli collapse. Preoxygenation is a major cause of atelectasis and continuing use of high oxygen concentration maintains or increases the lung collapse, that typically is 10% or more of the lung tissue. It can exceed 25% to 40%. Perfusion of the atelectasis causes shunt and cyclic airway closure causes regions with low ventilation/perfusion ratios, that add to impaired oxygenation. Ventilation with positive end-expiratory pressure reduces the atelectasis but oxygenation need not improve, because of shift of blood flow down the lung to any remaining atelectatic tissue. Inflation of the lung to an airway pressure of 40 cmH2O recruits almost all collapsed lung and the lung remains open if ventilation is with moderate oxygen concentration (< 40%) but recollapses within a few minutes if ventilation is with 100% oxygen. Severe obesity increases the lung collapse and obstructive lung disease and one-lung anesthesia increase the mismatch of ventilation and perfusion. CO2 pneumoperitoneum increases atelectasis formation but not shunt, likely explained by enhanced hypoxic pulmonary vasoconstriction by CO2. Atelectasis may persist in the postoperative period and contribute to pneumonia.