40 resultados para importance performance analysis
Meta-analysis: diagnostic performance of low-radiation-dose coronary computed tomography angiography
Resumo:
A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.
Resumo:
Patients with penetrating eye injuries are a very heterogeneous group both medically and economically. Since 2009, treatment involving sutures for open eye injuries and cases requiring amniotic membrane transplantation (AMT) were allocated to DRG C01B of the German diagnosis-related group system. However, given the significant clinical differences between these treatments, an inhomogeneity of costs to performance is postulated. This analysis describes case allocation problems within the G-DRG C01B category and presents solutions.
Resumo:
Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland.
Resumo:
To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT).
Resumo:
Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.
Resumo:
This survey was conducted in developing a final specialized examination for all arts therapists in Switzerland by the Council of Swiss Arts Therapy Associations (CSATA). Forty-eight generic key competencies (GKC) were sent to all 1235 arts therapists in five different disciplines in Switzerland (response 47.5%) and to 384 referring professionals and employers (RPE) listed by therapists (response 42%). The mean importance of GKC was rated high (4 points of 5) by practitioners and RPE. Different opinions on importance of GKC in disciplines included artistic ability and psychotherapeutic relative to medical orientation. The training of competencies was rated lower by practitioners (3.48 points) and different in the eight competence categories and five disciplines. Areas of weak training were identified. The performance of GKC was rated by referring professionals equally to its importance (mean +0.3 points) and showed a good understanding of competencies by RPE. Judging of performance was difficult for RPE in more than 20% of items. The results provide criteria for detailed outcome assessments and the advancement of a final examination for arts therapists in Switzerland.
Resumo:
BACKGROUND: In HIV type-1-infected patients starting highly active antiretroviral therapy (HAART), the prognostic value of haemoglobin when starting HAART, and of changes in haemoglobin levels, are not well defined. METHODS: We combined data from 10 prospective studies of 12,100 previously untreated individuals (25% women). A total of 4,222 patients (35%) were anaemic: 131 patients (1.1%) had severe (<8.0 g/dl), 1,120 (9%) had moderate (male 8.0-<11.0 g/dl and female 8.0- < 10.0 g/dl) and 2,971 (25%) had mild (male 11.0- < 13.0 g/ dl and female 10.0- < 12.0 g/dl) anaemia. We separately analysed progression to AIDS or death from baseline and from 6 months using Weibull models, adjusting for CD4+ T-cell count, age, sex and other variables. RESULTS: During 48,420 person-years of follow-up 1,448 patients developed at least one AIDS event and 857 patients died. Anaemia at baseline was independently associated with higher mortality: the adjusted hazard ratio (95% confidence interval) for mild anaemia was 1.42 (1.17-1.73), for moderate anaemia 2.56 (2.07-3.18) and for severe anaemia 5.26 (3.55-7.81). Corresponding figures for progression to AIDS were 1.60 (1.37-1.86), 2.00 (1.66-2.40) and 2.24 (1.46-3.42). At 6 months the prevalence of anaemia declined to 26%. Baseline anaemia continued to predict mortality (and to a lesser extent progression to AIDS) in patients with normal haemoglobin or mild anaemia at 6 months. CONCLUSIONS: Anaemia at the start of HAART is an important factor for short- and long-term prognosis, including in patients whose haemoglobin levels improved or normalized during the first 6 months of HAART.
Resumo:
An in vitro biomechanical investigation in the human lumbar spine focuses on the functional significance of vertebral bone density and intervertebral disc degenerations.
Resumo:
This paper presents problems arising from the lack of standardized methods for recording skeletal remains. Using practical examples it is shown how preservation and representation of bones can distort observations and how this can be reduced by systematic data acquisition.