41 resultados para formal verification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open-ended interviews of 90 min length of 38 patients were analyzed with respect to speech stylistics, shown by Schucker and Jacobs to differentiate individuals with type A personality features from those with type B. In our patients, Type A/B had been assessed by the Bortner Personality Inventory. The stylistics studied were: repeated words swallowed words, interruptions, simultaneous speech, silence latency (between question and answer) (SL), speed of speech, uneven speed of speech (USS), explosive words (PW), uneven speech volume (USV), and speech volume. Correlations between both raters for all speech categories were high. Positive correlations between extent of type A and SL (r = 0.33; p = 0.022), USS (r = 0.51; p = 0.002), PW (r = 0.46; p = 0.003) and USV (r = 0.39; p = 0.012) were found. Our results indicate that the speech in nonstress open-ended interviews of type A individuals tends to show a higher emotional tension (positive correlations for USS PW and USV) and is more controlled in conversation (positive correlation for SL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The role of the language network in the pathophysiology of formal thought disorder has yet to be elucidated. AIMS: To investigate whether specific grey-matter deficits in schizophrenic formal thought disorder correlate with resting perfusion in the left-sided language network. METHOD: We investigated 13 right-handed patients with schizophrenia and formal thought disorder of varying severity and 13 matched healthy controls, using voxel-based morphometry and magnetic resonance imaging perfusion measurement (arterial spin labelling). RESULTS: We found positive correlations between perfusion and the severity of formal thought disorder in the left frontal and left temporoparietal language areas. We also observed bilateral deficits in grey-matter volume, positively correlated with the severity of thought disorder in temporoparietal areas and other brain regions. The results of the voxel-based morphometry and the arterial spin labelling measurements overlapped in the left posterior superior temporal gyrus and left angular gyrus. CONCLUSIONS: Specific grey-matter deficits may be a risk factor for state-related dysfunctions of the left-sided language system, leading to local hyperperfusion and formal thought disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Optimal surgery for pleomorphic adenoma of the parotid is controversial. In the present review, we discuss the advantages and disadvantages of the various approaches after addressing the surgical pathology of the parotid pleomorphic adenoma capsule and its influence on surgery. DATA SOURCES PubMed literature searches were performed to identify original studies. CONCLUSIONS Almost all pleomorphic adenomas can be effectively treated by formal parotidectomy, but the procedure is not mandatory. Extracapsular dissection is a minimal margin surgery; therefore, in the hands of a novice or occasional parotid surgeon, it may result in higher rates of recurrence. Partial superficial parotidectomy may be a good compromise. The tumor is removed with a greater cuff of healthy parotid tissue than in extracapsular dissection. This may minimize the recurrence rate. On the other hand, the removal of healthy parotid tissue compared with formal parotidectomy is limited, thus minimizing complications such as facial nerve dysfunction and Frey syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.