67 resultados para eterogeneità, texture, analysis, CT, perfusionale, tumore
Resumo:
Recently, the field of forensics has experienced a rapid increase in the use of modern cross-sectional imaging in forensic investigations. We examined the value of post-mortem computed tomography (CT) imaging relative to autopsy for distinguishing aspiration into the lungs from airways, from lung alterations due to other causes, and for identifying the aspirated material. We selected 54 bodies submitted to whole-body CT scanning prior to autopsy. All cases had autopsy findings of blood (31 cases), fresh water (12 cases), or gastric content (11 cases) aspiration. The radiological images were retrospectively analyzed for airway and lung aspiration. In all cases, CT imaging detected pulmonary abnormalities suggestive of aspiration. Nevertheless, analysis of the CT images alone was not able to identify the aspirated material or to distinguish pulmonary findings of aspiration from lung changes due to other causes, except for a few cases of hemo-aspiration. However, due to its ability to visualize the entire parenchyma, CT imaging was superior to autopsy in providing additional data about the distribution and severity of the aspiration as well as in detecting small abnormalities. Post-mortem CT imaging should be considered as a superior tool for forensic investigations of aspiration due to its ability to document diagnostic conclusions and to guide the forensic pathologist during lung tissue examination.
Resumo:
Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.
Resumo:
We describe a case of exhumation, performed to investigate the circumstances and cause of death, one year after burial. Post mortem computed tomography (PMCT) revealed a mass in the pharynx. Imaging directed the subsequent forensic autopsy to careful retrieval of a foreign body. Histological analysis revealed a non-cellular composition. The detection of foreign material in the pharynx and its composition indicated accidental, rather than natural death, secondary to choking on food. This unusual case illustrates how post mortem imaging can significantly contribute to forensic investigation and stresses the importance of interdisciplinary collaboration between forensic pathologists and radiologists.
Resumo:
Sex determination in forensic practice is performed mostly on sexually dimorphic bones, including pelvic bones such as the os sacrum. Postmortem CT scan provides an easy and fast method for depicting and measuring bone structures prior to elaborate autopsy preparations. To develop a simple and objective method for sex determination in postmortem CT, metric data were evaluated from CT images of the pelvic-associated os sacrum of 95 corpses (49 men and 46 women) from the Canton of Bern, Switzerland. Discriminant function analysis of the data showed that the best accuracy in determining sex was 76.8% and 78.9% with two different observers. It is concluded that measuring the os sacrumin postmortem CT for sex determination has moderate accuracy and should only be applied in combination with other methods.
Resumo:
Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.
Resumo:
PURPOSE: The aim of this paper is to demonstrate that computed tomography (CT) and three-dimensional (3D) CT imaging techniques can be useful tools for evaluating gunshot wounds of the skull in forensic medicine. Three purposes can be achieved: (1) identifying and recognising the bullet entrance wound - and exit wound, if present; (2) recognising the bullet's intracranial course by studying damage to bone and brain tissue; (3) suggesting hypotheses as to the dynamics of the event. MATERIALS AND METHODS: Ten cadavers of people who died of a fatal head injury caused by a single gunshot were imaged with total-body CT prior to conventional autoptic examination. Three-dimensional-CT reconstructions were obtained with the volume-rendering technique, and data were analysed by two independent observers and compared with autopsy results. RESULTS: In our experience, CT analysis and volumetric reconstruction techniques allowed the identification of the bullet entrance and exit wounds and intracranial trajectory, as well as helping to formulate a hypothesis on the extracranial trajectory to corroborate circumstantial evidence. CONCLUSIONS: CT imaging techniques are excellent tools for addressing the most important questions of forensic medicine in the case of gunshot wounds of the skull, with results as good as (or sometimes better than) traditional autoptic methods.
Meta-analysis: diagnostic performance of low-radiation-dose coronary computed tomography angiography
Resumo:
A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.
Resumo:
BACKGROUND AND PURPOSE: Perfusion CT (P-CT) is used for acute stroke management, not, however, for evaluating epilepsy. To test the hypothesis that P-CT may identify patients with increased regional cerebral blood flow during subtle status epilepticus (SSE), we compared P-CT in SSE to different postictal conditions. METHODS: Fifteen patients (mean age 47 years, range 21-74) underwent P-CT immediately after evaluation in our emergency room. Asymmetry indices between affected and unaffected hemispheres were calculated for regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and mean transit time (MTT). Regional perfusion changes were compared to EEG findings. RESULTS: Three patients in subtle status epilepticus (group 1) had increased regional perfusion with electro-clinical correlate. Six patients showed postictal slowing on EEG corresponding to an area of regional hypoperfusion (group 2). CT and EEG were normal in six patients with a first epileptic seizure (group 3). Cluster analysis of asymmetry indices separated SSE from the other two groups in all three parameters, while rCBF helped to distinguish between chronic focal epilepsies and single events. CONCLUSION: Preliminary results indicate that P-CT may help to identify patients with SSE during emergency workup. This technique provides important information to neurologists or emergency physicians in the difficult clinical differential diagnosis of altered mental status due to subtle status epilepticus.
Resumo:
OBJECTIVES: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann dental implants with an SLA surface. MATERIAL AND METHODS: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). RESULTS: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. CONCLUSION: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact.
Resumo:
Objectives: - to monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics during the early phases of healing and incorporation of Straumann® dental implants with an SLA surface. Material and methods: 17 Straumann 4.1mm implants (10mm) and 7 Straumann 4.8mm implants (10mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). Results: Pocket probing depths ranged between 2-4mm and bleeding on probing between 5-20%. At baseline, BVD varied between 24 and 65% and BTC between 4.9 and 25.4 for the 4.1mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8mm diameter implants baseline ISQ values ranged from 57 – 70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. Conclusion: ISQ values of 57 – 70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since decease occurred after the fact.
Resumo:
The Cannabis plant and its products consist of an enormous variety of chemicals. Some of the 483 compounds identified are unique to Cannabis, for example, the more than 60 cannabinoids, whereas the terpenes, with about 140 members forming the most abundant class, are widespread in the plant kingdom. The term “cannabinoids” [note: “ ” represents a group of C21 terpenophenolic compounds found until now uniquely in Cannabis sativa L. (1). As a consequence of the development of synthetic cannabinoids (e.g., nabilone [2], HU-211 [dexanabinol; ref. (3), or ajulemic acid [CT-3; ref. 4]) and the discovery of the chemically different endogenous cannabinoid receptor ligands (“endocannabinoids,” e.g., anandamide, 2-arachidonoylglycerol) (5,6), the term ’“phytocannabinoids’” was proposed for these particular Cannabis constituents (7).
Resumo:
OBJECTIVES: We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND: Percutaneous coronary intervention in small-vessel disease is associated with an increased risk of major adverse cardiac events (MACE). METHODS: A total of 1,012 patients were randomly assigned to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of angiographic and clinical outcome was performed up to 2 years after PCI according to size of the treated vessel (reference vessel diameter < or =2.75 vs. >2.75 mm). RESULTS: Of 1,012 patients, 370 patients (37%) with 495 lesions underwent stent implantation in small vessels only, 504 patients (50%) with 613 lesions in large vessels only, and 138 patients (14%) with 301 lesions in both small and large vessels (mixed). In patients with small-vessel stents, SES reduced MACE by 55% (10.4% vs. 21.4%; p = 0.004), mainly driven by a 69% reduction of target lesion revascularization (TLR) (6.0% vs. 17.7%; p = 0.001) compared with PES at 2 years. In patients with large- and mixed-vessel stents, rates of MACE (large: 10.4% vs. 13.1%; p = 0.33; mixed: 16.7% vs. 18.0%; p = 0.83) and TLR (large: 6.9% vs. 8.6%; p = 0.47; mixed: 16.7% vs. 15.4%; p = 0.86) were similar for SES and PES. There were no significant differences with respect to death and myocardial infarction between the 3 groups. CONCLUSIONS: Compared with PES, SES more effectively reduced MACE and TLR in small-vessel disease. Differences between SES and PES appear less pronounced in patients with large- and mixed-vessel disease. (The SIRTAX trial; http://clinicaltrials.gov/ct/show/NCT00297661?order=1; NCT00297661).
Resumo:
Recent developments in clinical radiology have resulted in additional developments in the field of forensic radiology. After implementation of cross-sectional radiology and optical surface documentation in forensic medicine, difficulties in the validation and analysis of the acquired data was experienced. To address this problem and for the comparison of autopsy and radiological data a centralized database with internet technology for forensic cases was created. The main goals of the database are (1) creation of a digital and standardized documentation tool for forensic-radiological and pathological findings; (2) establishing a basis for validation of forensic cross-sectional radiology as a non-invasive examination method in forensic medicine that means comparing and evaluating the radiological and autopsy data and analyzing the accuracy of such data; and (3) providing a conduit for continuing research and education in forensic medicine. Considering the infrequent availability of CT or MRI for forensic institutions and the heterogeneous nature of case material in forensic medicine an evaluation of benefits and limitations of cross-sectional imaging concerning certain forensic features by a single institution may be of limited value. A centralized database permitting international forensic and cross disciplinary collaborations may provide important support for forensic-radiological casework and research.
Resumo:
Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients. METHODS: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with (99m)Tc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion. RESULTS: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P<0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P=0.004) and involvement of diagonal branches (P=0.01). CONCLUSION: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.
Resumo:
OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.