41 resultados para defect


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iatrogenic atrial septal defects are described in 2 patients. They occurred after implantation of Amplatzer occluders to close a patent foramen ovale. While device erosions to the extra-atrial space have been described, erosion induced atrial septal defects are a new medical entity. They may be fairly common in the situation of an atrial septal aneurysm whipping the rim of the device incessantly. They are clinically silent and benign and require echocardiography for detection. A second device solved the problem in the cases described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of irreversible pulmonary hypertension in patients with atrial septal defect (ASD) is thought to preclude shunt closure. We report the case of a woman with plexiform pulmonary arteriopathy secondary to an ostium secundum ASD who was able to successfully undergo percutaneous shunt closure following therapy with chronic intravenous prostacyclin (Flolan). One year after closure, the patient was weaned off Flolan over a period of 7 months following the institution of oral Bosentan therapy. Our case illustrates how aggressive vasodilator therapy with prostaglandins may be capable of reducing pulmonary artery pressure and permitting shunt closure in a patient once considered to have "inoperable" pulmonary arteriopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical study prospectively evaluated the healing outcome 1 year after apical surgery in relation to bony crypt dimensions measured intraoperatively. The study cohort included 183 teeth in an equal number of patients. For statistical analysis, results were dichotomized (healed versus non-healed cases). The overall success rate was 83% (healed cases). Healing outcome was not significantly related to the level and height of the facial bone plate. In contrast, a significant difference was found for the mean size of the bony crypt when healed cases (395 mm(3)) were compared with non-healed cases (554 mm(3)). In addition, healed cases had a significantly shorter mean distance (4.30 mm) from the facial bone surface to the root canal (horizontal access) compared with non-healed cases (5.13 mm). With logistic regression, however, the only parameter found to be significantly related to healing outcome was the length of the access window to the bony crypt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of how CFTR mutations other than F508del translate into the basic defect in cystic fibrosis (CF) is scarce due to the low incidence of homozygous index cases. METHODS: 17 individuals who are homozygous for deletions, missense, stop or splice site mutations in the CFTR gene were investigated for clinical symptoms of CF and assessed in CFTR function by sweat test, nasal potential difference and intestinal current measurement. RESULTS: CFTR activity in sweat gland, upper airways and distal intestine was normal for homozygous carriers of G314E or L997F and in the range of F508del homozygotes for homozygous carriers of E92K, W1098L, R553X, R1162X, CFTRdele2(ins186) or CFTRdele2,3(21 kb). Homozygotes for M1101K, 1898+3 A-G or 3849+10 kb C-T were not consistent CF or non-CF in the three bioassays. 14 individuals exhibited some chloride conductance in the airways and/or in the intestine which was identified by the differential response to cAMP and DIDS as being caused by CFTR or at least two other chloride conductances. DISCUSSION: CFTR mutations may lead to unusual electrophysiological or clinical manifestations. In vivo and ex vivo functional assessment of CFTR function and in-depth clinical examination of the index cases are indicated to classify yet uncharacterised CFTR mutations as either disease-causing lesions, risk factors, modifiers or neutral variants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial septal defects (ASDs) are typically asymptomatic in infancy and early childhood, and elective defect closure is usually performed at ages of 4 to 6 years. Severe pulmonary hypertension (PH) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PH complicating an isolated ASD and requiring early surgical correction. During a 10-year period (1996 to 2006), 355 pediatric patients underwent treatment for isolated ASDs either surgically or by catheter intervention at 2 tertiary referral centers. Two hundred ninety-seven patients had secundum ASDs, and 58 had primum ASDs with mild to moderate mitral regurgitation. Eight infants were found with isolated ASDs (6 with secundum ASDs and 2 with primum ASDs) associated with significant PH, accounting for 2.2% of all patients with ASDs at the centers. These 8 infants had invasively measured pulmonary artery pressures of 50% to 100% of systemic pressure. They were operated in the first year of life and had complicated postoperative courses requiring specific treatment for PH for up to 16 weeks postoperatively. The ultimate outcomes in all 8 infants were good, with persistent normalization of pulmonary pressures during midterm follow-up of up to 60 months (median 28). All other patients with ASDs had normal pulmonary pressures, and the mean age at defect closure was significantly older, at 6.2 years for secundum ASDs and 3.2 years for primum ASDs. In conclusion, ASDs were rarely associated with significant PH in infancy but then required early surgery and were associated with excellent midterm outcomes in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical magnetic resonance imaging (MRI) is the method of choice for the non-invasive evaluation of articular cartilage defects and the follow-up of cartilage repair procedures. The use of cartilage-sensitive sequences and a high spatial-resolution technique enables the evaluation of cartilage morphology even in the early stages of disease, as well as assessment of cartilage repair. Sequences that offer high contrast between articular cartilage and adjacent structures, such as the fat-suppressed, 3-dimensional, spoiled gradient-echo sequence and the fast spin-echo sequence, are accurate and reliable for evaluating intrachondral lesions and surface defects of articular cartilage. These sequences can also be performed together in reasonable examination times. In addition to morphology, new MRI techniques provide insight into the biochemical composition of articular cartilage and cartilage repair tissue. These techniques enable the diagnosis of early cartilage degeneration and help to monitor the effect and outcome of various surgical and non-surgical cartilage repair therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the case of a patient who presented with acute inferior myocardial infarction and embolic occlusion of the distal left anterior descending and proximal right coronary artery. A large atrial septal defect (ASD) was seen on transesophageal echocardiography and the ASD was closed during the same session as coronary angiography and percutaneous coronary intervention. The presence of embolic or thrombotic occlusions of coronary arteries should prompt interventional cardiologists to look for a patent foramen ovale or ASD and perform percutaneous closure right away.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 83-year-old woman underwent percutaneous closure of postinfarction ventricular septal defect following anteroseptal myocardial infarction and percutaneous coronary intervention with stent implantation of the left anterior descending coronary artery. Postinfarction percutaneous ventricular septal defect closure was initially complicated by an iatrogenic left ventricular free-wall perforation. Both defects were closed using two Amplatzer muscular VSD occluders during the same session.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the growing recognition of the patent foramen ovale (PFO), particularly when associated with an atrial septal aneurysm, as risk factor for several disease manifestations (above all paradoxical embolism), the optimal treatment strategy for symptomatic patients remains controversial. Percutaneous PFO closure is a minimally invasive procedure which can be performed with high success and low morbidity. For secondary prevention of recurrent embolic events, it appears to be clinically at least as effective as oral anticoagulation. Ventricular septal defects (VSDs) are the most common congenital heart defects. Percutaneous VSD closure is more intricate than PFO closure. It is associated with a significant risk of both peri-interventional and mid-term complications. In suitable patients with congenital VSD, device closure may well be the preferred treatment both for muscular or perimembranous VSDs and for residual defects after surgical VSD closure. The risk of complete atrioventricular conduction block remains a concern in the perimembranous group. The history, technique and clinical role of percutaneous PFO and VSD closure are discussed, with emphasis on current problems and future developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quickly localize defects, we want our attention to be focussed on relevant failing tests. We propose to improve defect localization by exploiting dependencies between tests, using a JUnit extension called JExample. In a case study, a monolithic white-box test suite for a complex algorithm is refactored into two traditional JUnit style tests and to JExample. Of the three refactorings, JExample reports five times fewer defect locations and slightly better performance (-8-12\%), while having similar maintenance characteristics. Compared to the original implementation, JExample greatly improves maintainability due the improved factorization following the accepted test quality guidelines. As such, JExample combines the benefits of test chains with test quality aspects of JUnit style testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sr2+ co-doped LaBr3:5%Ce scintillators show a record low energy resolution of 2% at 662 keV and a considerably better proportional response compared to standard LaBr3:5%Ce. This paper reports on the optical properties and time response of Sr co-doped LaBr3:5%Ce. Multiple excitation and emission bands were observed in X-ray and optically excited luminescence measurements. Those bands are ascribed to three different Ce3+ sites. The first is the unperturbed site with the same luminescence properties as those of standard LaBr3:Ce. The other two are perturbed sites with red-shifted 4f-5d1 Ce3+ excitation and emission bands, longer Ce3+ decay times, and smaller Stokes shifts. The lowering of the lowest 5d level of Ce3+ was ascribed to larger crystal field interactions at the perturbed sites. Two types of point defects in the LaBr3 matrix were proposed to explain the observed results. No Ce4+ ions were detected in Sr co-doped LaBr3:5%Ce by diffuse reflectance measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Osteochondral autograft transfer (OAT) aims at restoring normal articular cartilage surface geometry and articular contact mechanics. To date, no studies have evaluated the contact mechanics of the canine stifle following OAT. Additionally, there are no studies that evaluated the role of the meniscus in contact mechanics following OAT in human or canine femorotibial joints. The objective of this study was to measure the changes in femorotibial contact areas (CA), mean contact pressure (MCP) and peak contact pressure (PCP) before and after osteochondral autograft transplantation (OAT) of a simulated lateral femoral condylar cartilage defect with an intact lateral meniscus and following lateral meniscectomy. RESULTS With an intact lateral meniscus, creation of an osteochondral defect caused a decrease in MCP and PCP by 11% and 30%, respectively, compared to the intact stifle (p < 0.01). With an intact meniscus, implanting an osteochondral graft restored MCP and PCP to 96% (p = 0.56) and 92% (p = 0.41) of the control values. Lateral meniscectomy with grafting decreased CA by 54% and increased PCP by 79% compared to the intact stifle (p < 0.01). CONCLUSIONS OAT restored contact pressures in stifles with a simulated lateral condylar defect when the meniscus was intact. The lateral meniscus has a significant role in maintaining normal contact pressures in both stifles with a defect or following OAT. Meniscectomy should be avoided when a femoral condylar defect is present and when performing OAT.