45 resultados para compliant cryptologic protocols


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased fracture risk has been reported for the adjacent vertebral bodies after vertebroplasty. This increase has been partly attributed to the high Young's modulus of commonly used polymethylmethacrylate (PMMA). Therefore, a compliant bone cement of PMMA with a bulk modulus closer to the apparent modulus of cancellous bone has been produced. This compliant bone cement was achieved by introducing pores in the cement. Due to the reduced failure strength of that porous PMMA cement, cancellous bone augmented with such cement could deteriorate under dynamic loading. The aim of the present study was to assess the potential of acute failure, particle generation and mechanical properties of cancellous bone augmented with this compliant cement in comparison to regular cement. For this purpose, vertebral biopsies were augmented with porous- and regular PMMA bone cement, submitted to dynamic tests and compression to failure. Changes in Young's modulus and height due to dynamic loading were determined. Afterwards, yield strength and Young's modulus were determined by compressive tests to failure and compared to the individual composite materials. No failure occurred and no particle generation could be observed during dynamical testing for both groups. Height loss was significantly higher for the porous cement composite (0.53+/-0.21%) in comparison to the biopsies augmented with regular cement (0.16+/-0.1%). Young's modulus of biopsies augmented with porous PMMA was comparable to cancellous bone or porous cement alone (200-700 MPa). The yield strength of those biopsies (21.1+/-4.1 MPa) was around two times higher than for porous cement alone (11.6+/-3.3 MPa).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the feasibility of and interactions among three software-driven critical care protocols. DESIGN: Prospective cohort study. SETTING: Intensive care units in six European and American university hospitals. PATIENTS: 174 cardiac surgery and 41 septic patients. INTERVENTIONS: Application of software-driven protocols for cardiovascular management, sedation, and weaning during the first 7 days of intensive care. MEASUREMENTS AND RESULTS: All protocols were used simultaneously in 85% of the cardiac surgery and 44% of the septic patients, and any one of the protocols was used for 73 and 44% of study duration, respectively. Protocol use was discontinued in 12% of patients by the treating clinician and in 6% for technical/administrative reasons. The number of protocol steps per unit of time was similar in the two diagnostic groups (n.s. for all protocols). Initial hemodynamic stability (a protocol target) was achieved in 26+/-18 min (mean+/-SD) in cardiac surgery and in 24+/-18 min in septic patients. Sedation targets were reached in 2.4+/-0.2h in cardiac surgery and in 3.6 +/-0.2h in septic patients. Weaning protocol was started in 164 (94%; 154 extubated) cardiac surgery and in 25 (60%; 9 extubated) septic patients. The median (interquartile range) time from starting weaning to extubation (a protocol target) was 89 min (range 44-154 min) for the cardiac surgery patients and 96 min (range 56-205 min) for the septic patients. CONCLUSIONS: Multiple software-driven treatment protocols can be simultaneously applied with high acceptance and rapid achievement of primary treatment goals. Time to reach these primary goals may provide a performance indicator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Facial esthetics play an important role in social interactions. However, children with a repaired complete unilateral cleft lip and palate usually show some disfigurement of the nasolabial area. To date, few studies have assessed the nasolabial appearance after different treatment protocols. The aim of the present study was to compare the nasolabial esthetics after 1- and 3-stage treatment protocols. MATERIALS AND METHODS: Four components of the nasolabial appearance (nasal form, nasal deviation, mucocutaneous junction, and profile view) were assessed by 4 raters in 108 consecutively treated children who had undergone either 1-stage closure (Warsaw group, 41 boys and 19 girls, mean age 10.8 years, SD 2.0) or 3-stage (Nijmegen group, 30 boys and 18 girls, mean age 8.9 years, SD 0.7). A 5-grade esthetic index of Asher-McDade was used, in which grade 1 indicates the most esthetic and grade 5 the least esthetic outcome. RESULTS: The nasal form was judged the least esthetic in both groups and graded 3.1 (SD 1.1) and 3.2 (SD 1.1). The nasal deviation, mucocutaneous junction, and profile view were scored from 2.1 (SD 0.8) to 2.3 (SD 1.0) in both groups. The treatment outcome after the Warsaw and Nijmegen protocols was comparable. Neither overall nor any of the 4 components of the nasolabial appearance showed intercenter differences (P > .1). CONCLUSIONS: The nasolabial appearance after the Warsaw (1-stage) and Nijmegen (3-stage) protocols was comparable. The technique of lip repair (triangular flap in Warsaw and Millard rotation advancement in Nijmegen) gave comparable results for the esthetics of the nasolabial area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate early and immediate loading of implants in the posterior maxilla and to investigate whether there is a difference in success rates, survival rates, and peri-implant parameters, including marginal bone level changes. MATERIALS AND METHODS: A comprehensive systematic review of the literature was conducted. The selection of publications reporting on human clinical studies was based on predetermined inclusion criteria and was agreed upon by two reviewers. RESULTS: Twelve papers were identified on early loading (two randomized controlled clinical trials [RCTs] and 10 prospective case series studies). Six papers were found on immediate loading (one RCT, four prospective case series, and one retrospective study). CONCLUSIONS: Under certain circumstances it is possible to successfully load dental implants in the posterior maxilla early or immediately after their placement in selected patients. The success rate appears to be technique sensitive, although no study has directly assessed this. A high degree of primary implant stability (high value of insertion torque) and implant surface characteristics play an important role. It is not possible to draw evidence-based conclusions concerning contraindications, threshold values for implant stability, bone quality and quantity needed, or impact of occlusal loading forces. As for the impact of the surgical technique on implant outcome in different bone densities, no studies prove significant superior results with one technique over another. Well-designed RCTs with a large number of patients are necessary to make early/immediate loading protocols in posterior maxilla evidence based, but ethical and practical considerations may limit the real possibility of such studies in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection rate of pulmonary emboli (PE) with computed tomography angiography (CTA) using either a standard or a low-dose protocol, combining reduced radiation exposure and iodine delivery rate, was retrospectively analyzed in a matched cohort of 120 patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND There is weak evidence to support the benefit of periodontal maintenance therapy in preventing tooth loss. In addition, the effects of long-term periodontal treatment on general health are unclear. METHODS Patients who were compliant and partially compliant (15 to 25 years' follow-up) in private practice were observed for oral and systemic health changes. RESULTS A total of 219 patients who were compliant (91 males and 128 females) were observed for 19.1 (range 15 to 25; SD ± 2.8) years. Age at reassessment was 64.6 (range: 39 to 84; SD ± 9.0) years. A total of 145 patients were stable (0 to 3 teeth lost), 54 were downhill (4 to 6 teeth lost), and 21 patients extreme downhill (>6 teeth lost); 16 patients developed hypertension, 13 developed type 2 diabetes, and 15 suffered myocardial infarcts (MIs). A minority developed other systemic diseases. Risk factors for MI included overweight (odds ratio [OR]: 9.04; 95% confidence interval [CI]: 2.9 to 27.8; P = 0.000), family history with cardiovascular disease (OR: 3.10; 95% CI: 1.07 to 8.94; P = 0.029), type 1 diabetes at baseline (P = 0.02), and developing type 2 diabetes (OR: 7.9; 95% CI: 2.09 to 29.65; P = 0.000). A total of 25 patients who were partially compliant (17 males and eight females) were observed for 19 years. This group had a higher proportion of downhill and extreme downhill cases and MI. CONCLUSIONS Patients who left the maintenance program in a periodontal specialist practice in Norway had a higher rate of tooth loss than patients who were compliant. Patients who were compliant with maintenance in a specialist practice in Norway have a similar risk of developing type 2 diabetes as the general population. A rate of 0.0037 MIs per patient per year was recorded for this group. Due to the lack of external data, it is difficult to assess how this compares with patients who have periodontal disease and are untreated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND To standardize multiple-breath washout (MBW) measurements, 1L tidal volume (VT) protocols were suggested. The effect on MBW derived ventilation inhomogeneity (VI) indices is unclear. METHODS We compared VI indices from free breathing MBW at baseline to 1L VT MBW performed in triplicates in 35 children (20 with CF). Mean (range) age was 12.8 (7.0-16.7) years, weight 42 (20-64) kg and height 151 (117-170) cm. RESULTS Baseline lung clearance index (LCI) increased from mean (SD) 11.0 (2.2) to 13.0 (2.6), p=0.011, in CF and from 6.8 (0.5) to 7.7 (1.4), p=0.004, in controls. Moment ratio and Scond similarly increased. While change in VI indices was heterogeneous in individuals, decrease in functional residual capacity was most strongly associated with LCI increase. CONCLUSION MBW protocols strongly influence measures of VI. The 1L VT MBW protocol leads to overestimation of VI and is not recommended in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable and robust routing service for Flying Ad-Hoc Networks (FANETs) must be able to adapt to topology changes, and also to recover the quality level of the delivered multiple video flows under dynamic network topologies. The user experience on watching live videos must also be satisfactory even in scenarios with network congestion, buffer overflow, and packet loss ratio, as experienced in many FANET multimedia applications. In this paper, we perform a comparative simulation study to assess the robustness, reliability, and quality level of videos transmitted via well-known beaconless opportunistic routing protocols. Simulation results shows that our developed protocol XLinGO achieves multimedia dissemination with Quality of Experience (QoE) support and robustness in a multi-hop, multi-flow, and mobile networks, as required in many multimedia FANET scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate if pre-anaesthetic thoracic radiographs contribute to the anaesthetic management of trauma patients by comparing American Society of Anesthesiologists Physical Status Classification (ASA grade) with and without information from thoracic radiography findings. Case records of 157 dogs and cats being anaesthetized with or without post-traumatic, pre-anaesthetic chest radiographs were retrospectively evaluated for clinical parameters, radiographic abnormalities and anaesthetic protocol. Animals were retrospectively assigned an ASA grade. ASA grades, clinical signs of respiratory abnormalities and anaesthesia protocols were compared between animals with and without chest radiographs. The group of animals without pre-anaesthetic radiographs was anaesthetized earlier after trauma and showed less respiratory abnormalities at presentation. The retrospectively evaluated ASA grade significantly increased with the information from thoracic radiography. Animals with a higher ASA grade were less frequently mechanically ventilated. Pre-anaesthetic radiographs may provide important information to assess the ASA grade in traumatized patients and may therefore influence the anesthesia protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.