85 resultados para cofenetic correlation coefficient


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose Orthognathic surgery has the objective of altering facial balance to achieve esthetic results in patients who have severe disharmony of the jaws. The purpose was to quantify the soft tissue changes after orthognathic surgery, as well as to assess the differences in 3D soft tissue changes in the middle and lower third of the face between the 1- and 2-jaw surgery groups, in mandibular prognathism patients. Materials and Methods We assessed soft tissue changes of patients who have been diagnosed with mandibular prognathism and received either isolated mandibular surgery or bimaxillary surgery. The quantitative surface displacement was assessed by superimposing preoperative and postoperative volumetric images. An observer measured a surface-distance value that is shown as a contour line. Differences between the groups were determined by the Mann-Whitney U test. The Spearman correlation coefficient was used to evaluate a potential correlation between patients' surgical and cephalometric variables and soft tissue changes after orthognathic surgery in each group. Results There were significant differences in the middle third of the face between the 1- and 2-jaw surgery groups. Soft tissues in the lower third of the face changed in both surgery groups, but not significantly. The correlation patterns were more evident in the lower third of the face. Conclusion The overall soft tissue changes of the midfacial area were more evident in the 2-jaw surgery group. In 2-jaw surgery, significant changes would be expected in the midfacial area, but caution should be exercised in patients who have a wide alar base.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tumor budding is recognized by the World Health Organization as an additional prognostic factor in colorectal cancer but remains unreported in diagnostic work due to the absence of a standardized scoring method. This study aims to assess the most prognostic and reproducible scoring systems for tumor budding in colorectal cancer. Tumor budding on pancytokeratin-stained whole tissue sections from 105 well-characterized stage II patients was scored by 3 observers using 7 methods: Hase, Nakamura, Ueno, Wang (conventional and rapid method), densest high-power field, and 10 densest high-power fields. The predictive value for clinicopathologic features, the prognostic significance, and interobserver variability of each scoring method was analyzed. Pancytokeratin staining allowed accurate evaluation of tumor buds. Interobserver agreement for 3 observers was excellent for densest high-power field (intraclass correlation coefficient, 0.83) and 10 densest high-power fields (intraclass correlation coefficient, 0.91). Agreement was moderate to substantial for the conventional Wang method (κ = 0.46-0.62) and moderate for the rapid method (κ = 0.46-0.58). For Nakamura, moderate agreement (κ = 0.41-0.52) was reached, whereas concordance was fair to moderate for Ueno (κ = 0.39-0.56) and Hase (κ = 0.29-0.51). The Hase, Ueno, densest high-power field, and 10 densest high-power field methods identified a significant association of tumor budding with tumor border configuration. In multivariate analysis, only tumor budding as evaluated in densest high-power field and 10 densest high-power fields had significant prognostic effects on patient survival (P < .01), with high prognostic accuracy over the full 10-year follow-up. Scoring tumor buds in 10 densest high-power fields is a promising method to identify stage II patients at high risk for recurrence in daily diagnostics; it is highly reproducible, accounts for heterogeneity, and has a strong predictive value for adverse outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although tumor budding is linked to adverse prognosis in colorectal cancer, it remains largely unreported in daily diagnostic work due to the absence of a standardized scoring method. Our aim was to assess the inter-observer agreement of a novel 10-high-power-fields method for assessment of tumor budding at the invasive front and to confirm the prognostic value of tumor budding in our setting of colorectal cancers. Whole tissue sections of 215 colorectal cancers with full clinico-pathological and follow-up information were stained with cytokeratin AE1/AE3 antibody. Presence of buds was scored across 10-high-power fields at the invasive front by two pathologists and two additional observers were asked to score 50 cases of tumor budding randomly selected from the larger cohort. The measurements were correlated to the patient and tumor characteristics. Inter-observer agreement and correlation between observers' scores were excellent (P<0.0001; intraclass correlation coefficient=0.96). A test subgroup of 65 patients (30%) was used to define a valid cutoff score for high-grade tumor budding and the remaining 70% of the patients were entered into the analysis. High-grade budding was defined as an average of ≥10 buds across 10-high-power fields. High-grade budding was associated with a higher tumor grade (P<0.0001), higher TNM stage (P=0.0003), vascular invasion (P<0.0001), infiltrating tumor border configuration (P<0.0001) and reduced survival (P<0.0001). Multivariate analysis confirmed its independent prognostic effect (P=0.007) when adjusting for TNM stage and adjuvant therapy. Using 10-high-power fields for evaluating tumor budding has independent prognostic value and shows excellent inter-observer agreement. Like the BRE and Gleason scores in breast and prostate cancers, respectively, tumor budding could be a basis for a prognostic score in colorectal cancer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new approach for the determination of free and total valproic acid in small samples of 140 μL human plasma based on capillary electrophoresis with contactless conductivity detection is proposed. A dispersive liquid-liquid microextraction technique was employed in order to remove biological matrices prior to instrumental analysis. The free valproic acid was determined by isolating free valproic acid from protein-bound valproic acid by ultrafiltration under centrifugation of 100 μL sample. The filtrate was acidified to turn valproic acid into its protonated neutral form and then extracted. The determination of total valproic acid was carried out by acidifying 40 μL untreated plasma to release the protein-bound valproic acid prior to extraction. A solution consisting of 10 mM histidine, 10 mM 3-(N-morpholino)propanesulfonic acid and 10 μM hexadecyltrimethylammonium bromide of pH 6.5 was used as background electrolyte for the electrophoretic separation. The method showed good linearity in the range of 0.4-300 μg/mL with a correlation coefficient of 0.9996. The limit of detection was 0.08 μg/mL, and the reproducibility of the peak area was excellent (RSD=0.7-3.5%, n=3, for the concentration range from 1 to 150 μg/mL). The results for the free and total valproic acid concentration in human plasma were found to be comparable to those obtained with a standard immunoassay. The corresponding correlation coefficients were 0.9847 for free and 0.9521 for total valproic acid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Available evidence suggests that the use of CO(2) insufflation in endoscopy is more comfortable for the patient. The safety of CO(2) use in colonoscopy remains contentious, particularly in sedated patients. The objective of the present prospective trial was to assess the safety of CO(2) colonoscopies. Methods. 109 patients from our previous randomized CO(2) colonoscopy study and an additional 238 subsequent consecutive unselected patients who had a routine colonoscopy performed in a private practice were enrolled from April 2008 through September 2008. All but 2 patients were sedated. All patients were routinely monitored with transcutaneous CO(2) measurement. Volumes of CO(2) administered were correlated with capnographic measurements from transcutaneous monitoring. Results. Of the 347 patients examined, 57% were women; mean (SD) age of participants was of 60.2 years (12.8). Mean propofol dosage was 136 mg (64 mg). Mean CO(2) values were 34.7 mm Hg (5.3) at baseline, 38.9 mm Hg (5.5) upon reaching the ileum, and 36.9 mm Hg (5.0) at examination's end. Mean maximum increase of CO(2) was 4.5 mm Hg (3.6). No correlation was observed between volume of CO(2) administered and increase in level of CO(2) (correlation coefficient: 0.01; P value: 0.84). No complications were observed. Conclusions. The present prospective study, which was based on one of the largest sedated patient sample reported to date in this setting, provides compelling evidence that CO(2) insufflation in colonoscopy is safe and unassociated with relevant increases in transcutaneously measured levels of CO(2).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. DESIGN: Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. PATIENTS: One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. RESULTS: The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. CONCLUSION: This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA) measurements that are independent of corneal thickness and curvature, and to assess variables of observer agreement. METHODS: In a multivariate cluster analysis on 223 eyes, the relationship between central corneal thickness, corneal curvature, axial length, anterior chamber depth, intraocular pressure, sex, age, and OPA measurements was assessed. Intraobserver and interobserver variabilities were calculated from repeated measurements obtained from 8 volunteers by 4 observers. RESULTS: The OPA readings were not affected by central corneal thickness (P = .08), corneal curvature (P = .47), anterior chamber depth (P = .80), age (P = .60), or sex (P = .73). There was a positive correlation between OPA and intraocular pressure (0.12 mm Hg/1 mm Hg of intraocular pressure; P<.001) and a negative correlation between OPA and axial length (0.27 mm Hg/1 mm of length; P<.001). Intraobserver and interobserver variabilities were 0.08 and 0.02 mm Hg, respectively, and the intraclass correlation coefficient was 0.89. CONCLUSIONS: The OPA readings obtained with dynamic contour tonometry in healthy subjects are not influenced by the structure of the anterior segment of the eye but are affected by intraocular pressure and axial length. We found a high amount of agreement within and between observers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to compare the maximum urethral closure pressure (MUCP) measures with two different techniques: water perfused catheter and microtip transducer catheters with respect to reproducibility and comparability for urethral pressure measurements. Eighteen women with stress urinary incontinence had repeat static urethral pressure profilometry on a different day using a dual microtip transducer and water perfused catheter (Brown and Wickham). The investigators were blinded to the results of the other. The microtip measurements were taken in the 45 degrees upright sitting position with the patient at rest at a bladder capacity of 250 ml using an 8 Fr Gaeltec(R) double microtip transducer withdrawn at 1 mm/s, and the transducer was orientated in the three o'clock position. Three different measures were taken for each patient. Three water perfusion measurements were performed with the patient at rest in the 45 degrees upright position at a bladder capacity of 250 ml using an 8 Fr BARD dual lumen catheter withdrawn at 1 mm/s. The mean water perfusion MUCP measure was 26.1 cm H(2)0, significantly lower than the mean microtip measure of 35.7 cm H(2)0. The correlation coefficient comparing each water perfusion measurement with the other water perfusion measures in the same patient was excellent, at 0.95 (p = 0.01). Correlation coefficient comparing each microtip measure with the other microtip measure in the same patient was also good, ranging from 0.70 to 0.80. This study confirms that both water perfusion catheters and microtip transducers have excellent or very good reproducibility with an acceptable intraindividual variation for both methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To develop and evaluate a short form of the 24-item Geriatric Pain Measure (GPM) for use in community-dwelling older adults. DESIGN: Derivation and validation of a 12-item version of the GPM in a European and an independent U.S. sample of community-dwelling older adults. SETTING: Three community-dwelling sites in London, United Kingdom; Hamburg, Germany; Solothurn, Switzerland; and two ambulatory geriatrics clinics in Los Angeles, California. PARTICIPANTS: European sample: 1,059 community-dwelling older persons from three sites (London, UK; Hamburg, Germany; Solothurn, Switzerland); validation sample: 50 persons from Los Angeles, California, ambulatory geriatric clinics. MEASUREMENTS: Multidimensional questionnaire including self-reported demographic and clinical information. RESULTS: Based on item-to-total scale correlations in the European sample, 11 of 24 GPM items were selected for inclusion in the short form. One additional item (pain-related sleep problems) was included based on clinical relevance. In the validation sample, the Cronbach alpha of GPM-12 was 0.92 (individual subscale range 0.77-0.92), and the Pearson correlation coefficient (r) between GPM-12 and the original GPM was 0.98. The correlation between the GPM-12 and the McGill Pain Questionnaire was 0.63 (P<.001), similar to the correlation between the original GPM and the McGill Pain Questionnaire (Pearson r=0.63; P<.001). Exploratory factor analysis indicated that the GPM-12 covers three subfactors (pain intensity, pain with ambulation, disengagement because of pain). CONCLUSION: The GPM-12 demonstrated good validity and reliability in these European and U.S. populations of older adults. Despite its brevity, the GPM-12 captures the multidimensional nature of pain in three subscales. The self-administered GPM-12 may be useful in the clinical assessment process and management of pain and in pain-related research in older persons.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

SETTING: Kinshasa Province, Democratic Republic of Congo. OBJECTIVE: To identify and validate register-based indicators of acid-fast bacilli (AFB) microscopy quality. DESIGN: Selection of laboratories based on reliability and variation in routine smear rechecking results. Calculation of relative sensitivity (RS) compared to recheckers and its correlation coefficient (R) with candidate indicators based on a fully probabilistic analysis incorporating vague prior information using WinBUGS. RESULTS: The proportion of positive follow-up smears correlated well (median R 0.81, 95% credibility interval [CI] 0.58-0.93), and the proportion of first smear-positive cases fairly (median R 0.70, 95% CI 0.38-0.89) with RS. The proportions of both positive suspect and low positive case smears showed poor correlations (median R 0.27 and -0.22, respectively, with ranges including zero). CONCLUSIONS: The proportion of positives in follow-up smears is the most promising indicator of AFB smear sensitivity, while the proportion of positive suspects may be more indicative of accessibility and suspect selection. Both can be obtained from simple reports, and should be used for internal and external monitoring and as guidance for supervision. As proportion of low positive suspect smears and consistency within case series are more difficult to interpret, they should be used only on-site by laboratory professionals. All indicators require more research to define their optimal range in various settings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A CT-based method ("HipMotion") for the noninvasive three-dimensional assessment of femoroacetabular impingement (FAI) was developed, validated, and applied in a clinical pilot study. The method allows for the anatomically based calculation of hip range of motion (ROM), the exact location of the impingement zone, and the simulation of quantified surgical maneuvers for FAI. The accuracy of HipMotion was 0.7 +/- 3.1 degrees in a plastic bone setup and -5.0 +/- 5.6 degrees in a cadaver setup. Reliability and reproducibility were excellent [intraclass correlation coefficient (ICC) > 0.87] for all measures except external rotation (ICC = 0.48). The normal ROM was determined from a cohort of 150 patients and was compared to 31 consecutive hips with FAI. Patients with FAI had a significantly decreased flexion, internal rotation, and abduction in comparison to normal hips (p < 0.001). Normal hip flexion and internal rotation are generally overestimated in a number of orthopedic textbooks. HipMotion is a useful tool for further assessment of impinging hips and for appropriate planning of the necessary amount of surgical intervention, which represents the basis for future computer-assisted treatment of FAI with less invasive surgical approaches, such as hip arthroscopy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nitrous oxide fluxes were measured at the Lägeren CarboEurope IP flux site over the multi-species mixed forest dominated by European beech and Norway spruce. Measurements were carried out during a four-week period in October–November 2005 during leaf senescence. Fluxes were measured with a standard ultrasonic anemometer in combination with a quantum cascade laser absorption spectrometer that measured N2O, CO2, and H2O mixing ratios simultaneously at 5 Hz time resolution. To distinguish insignificant fluxes from significant ones it is proposed to use a new approach based on the significance of the correlation coefficient between vertical wind speed and mixing ratio fluctuations. This procedure eliminated roughly 56% of our half-hourly fluxes. Based on the remaining, quality checked N2O fluxes we quantified the mean efflux at 0.8±0.4 μmol m−2 h−1 (mean ± standard error). Most of the contribution to the N2O flux occurred during a 6.5-h period starting 4.5 h before each precipitation event. No relation with precipitation amount could be found. Visibility data representing fog density and duration at the site indicate that wetting of the canopy may have as strong an effect on N2O effluxes as does below-ground microbial activity. It is speculated that above-ground N2O production from the senescing leaves at high moisture (fog, drizzle, onset of precipitation event) may be responsible for part of the measured flux.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Heart rate variability (HRV) and cardiorespiratory coordination, i.e. the temporal interplay between oscillations of heartbeat and respiration, reflect information related to the cardiovascular and autonomic nervous system. The purpose of this study was to investigate the relationship between spectral measures of HRV and measures of cardiorespiratory coordination. In 127 subjects from a normal population a 24 h Holter ECG was recorded. Average heart rate (HR) and the following HRV parameters were calculated: very low (VLF), low (LF) and high frequency (HF) oscillations and LF/HF. Cardiorespiratory coordination was quantified using average respiratory rate (RespR), the ratio of heart rate and respiratory rate (HRR), the phase coordination ratio (PCR) and the extent of cardiorespiratory coordination (PP). Pearson's correlation coefficient r was used to quantify the relationship between each pair of the variables across all subjects. HR and HRR correlated strongest during daytime (r = 0.89). LF/HF and PP showed a negative correlation to a reasonable degree (r = -0.69). During nighttime sleep these correlations decreased whereas the correlation between HRR and RespR (r = -0.47) as well as between HRR and PCR (r = 0.73) increased substantially. In conclusion, HRR and PCR deliver considerably different information compared to HRV measures whereas PP is partially linked reciprocally to LF/HF.