19 resultados para attrition and chipping


Relevância:

30.00% 30.00%

Publicador:

Resumo:

River bedload surveyed at 50 sites in Westland is dominated by Alpine Schist or Torlesse Greywacke from the Alpine Fault hanging wall, with subordinate Pounamu Ultramafics or footwall-derived Western Province rocks. Tumbling experiments found ultramafics to have the lowest attrition rates, compared with greywacke sandstone and granite (which abrade to produce silt to medium-sand), or incompetent schist (which fragments). Arahura has greater total concentrations (103–105 t/km2) and proportions (5–40%) of ultramafic bedload compared with Hokitika and Taramakau catchments (101–104 t/km2, mostly <10%), matching relative areas of mapped Pounamu Ultramafic bedrock, but enriched relative to absolute areal proportions. Western Province rocks downthrown by the Alpine Fault are under-represented in the bedload. Enriched concentrations of ultramafic bedload decrease rapidly with distance downstream from source rock outcrops, changing near prominent ice-limit moraines. Bedload evolution with transport involves both downstream fining and dilution from tributaries, in a sediment supply regime more strongly influenced by tectonics and the imprint of past glaciation. Treasured New Zealand pounamu (jade) is associated with ultramafic rocks. Chances of discovery vary between catchments, are increased near glacial moraines, and are highest near source-rock outcrops in remote mountain headwaters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Febrile neutropenia (FN) and other infectious complications are some of the most serious treatment-related toxicities of chemotherapy for cancer, with a mortality rate of 2% to 21%. The two main types of prophylactic regimens are granulocyte (macrophage) colony-stimulating factors (G(M)-CSF) and antibiotics, frequently quinolones or cotrimoxazole. Current guidelines recommend the use of colony-stimulating factors when the risk of febrile neutropenia is above 20%, but they do not mention the use of antibiotics. However, both regimens have been shown to reduce the incidence of infections. Since no systematic review has compared the two regimens, a systematic review was undertaken. OBJECTIVES To compare the efficacy and safety of G(M)-CSF compared to antibiotics in cancer patients receiving myelotoxic chemotherapy. SEARCH METHODS We searched The Cochrane Library, MEDLINE, EMBASE, databases of ongoing trials, and conference proceedings of the American Society of Clinical Oncology and the American Society of Hematology (1980 to December 2015). We planned to include both full-text and abstract publications. Two review authors independently screened search results. SELECTION CRITERIA We included randomised controlled trials (RCTs) comparing prophylaxis with G(M)-CSF versus antibiotics for the prevention of infection in cancer patients of all ages receiving chemotherapy. All study arms had to receive identical chemotherapy regimes and other supportive care. We included full-text, abstracts, and unpublished data if sufficient information on study design, participant characteristics, interventions and outcomes was available. We excluded cross-over trials, quasi-randomised trials and post-hoc retrospective trials. DATA COLLECTION AND ANALYSIS Two review authors independently screened the results of the search strategies, extracted data, assessed risk of bias, and analysed data according to standard Cochrane methods. We did final interpretation together with an experienced clinician. MAIN RESULTS In this updated review, we included no new randomised controlled trials. We included two trials in the review, one with 40 breast cancer patients receiving high-dose chemotherapy and G-CSF compared to antibiotics, a second one evaluating 155 patients with small-cell lung cancer receiving GM-CSF or antibiotics.We judge the overall risk of bias as high in the G-CSF trial, as neither patients nor physicians were blinded and not all included patients were analysed as randomised (7 out of 40 patients). We considered the overall risk of bias in the GM-CSF to be moderate, because of the risk of performance bias (neither patients nor personnel were blinded), but low risk of selection and attrition bias.For the trial comparing G-CSF to antibiotics, all cause mortality was not reported. There was no evidence of a difference for infection-related mortality, with zero events in each arm. Microbiologically or clinically documented infections, severe infections, quality of life, and adverse events were not reported. There was no evidence of a difference in frequency of febrile neutropenia (risk ratio (RR) 1.22; 95% confidence interval (CI) 0.53 to 2.84). The quality of the evidence for the two reported outcomes, infection-related mortality and frequency of febrile neutropenia, was very low, due to the low number of patients evaluated (high imprecision) and the high risk of bias.There was no evidence of a difference in terms of median survival time in the trial comparing GM-CSF and antibiotics. Two-year survival times were 6% (0 to 12%) in both arms (high imprecision, low quality of evidence). There were four toxic deaths in the GM-CSF arm and three in the antibiotics arm (3.8%), without evidence of a difference (RR 1.32; 95% CI 0.30 to 5.69; P = 0.71; low quality of evidence). There were 28% grade III or IV infections in the GM-CSF arm and 18% in the antibiotics arm, without any evidence of a difference (RR 1.55; 95% CI 0.86 to 2.80; P = 0.15, low quality of evidence). There were 5 episodes out of 360 cycles of grade IV infections in the GM-CSF arm and 3 episodes out of 334 cycles in the cotrimoxazole arm (0.8%), with no evidence of a difference (RR 1.55; 95% CI 0.37 to 6.42; P = 0.55; low quality of evidence). There was no significant difference between the two arms for non-haematological toxicities like diarrhoea, stomatitis, infections, neurologic, respiratory, or cardiac adverse events. Grade III and IV thrombopenia occurred significantly more frequently in the GM-CSF arm (60.8%) compared to the antibiotics arm (28.9%); (RR 2.10; 95% CI 1.41 to 3.12; P = 0.0002; low quality of evidence). Neither infection-related mortality, incidence of febrile neutropenia, nor quality of life were reported in this trial. AUTHORS' CONCLUSIONS As we only found two small trials with 195 patients altogether, no conclusion for clinical practice is possible. More trials are necessary to assess the benefits and harms of G(M)-CSF compared to antibiotics for infection prevention in cancer patients receiving chemotherapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To identify the influence of fixed prosthesis type on biologic and technical complication rates in the context of screw versus cement retention. Furthermore, a multivariate analysis was conducted to determine which factors, when considered together, influence the complication and failure rates of fixed implant-supported prostheses. MATERIALS AND METHODS Electronic searches of MEDLINE (PubMed), EMBASE, and the Cochrane Library were conducted. Selected inclusion and exclusion criteria were used to limit the search. Data were analyzed statistically with simple and multivariate random-effects Poisson regressions. RESULTS Seventy-three articles qualified for inclusion in the study. Screw-retained prostheses showed a tendency toward and significantly more technical complications than cemented prostheses with single crowns and fixed partial prostheses, respectively. Resin chipping and ceramic veneer chipping had high mean event rates, at 10.04 and 8.95 per 100 years, respectively, for full-arch screwed prostheses. For "all fixed prostheses" (prosthesis type not reported or not known), significantly fewer biologic and technical complications were seen with screw retention. Multivariate analysis revealed a significantly greater incidence of technical complications with cemented prostheses. Full-arch prostheses, cantilevered prostheses, and "all fixed prostheses" had significantly higher complication rates than single crowns. A significantly greater incidence of technical and biologic complications was seen with cemented prostheses. CONCLUSION Screw-retained fixed partial prostheses demonstrated a significantly higher rate of technical complications and screw-retained full-arch prostheses demonstrated a notably high rate of veneer chipping. When "all fixed prostheses" were considered, significantly higher rates of technical and biologic complications were seen for cement-retained prostheses. Multivariate Poisson regression analysis failed to show a significant difference between screw- and cement-retained prostheses with respect to the incidence of failure but demonstrated a higher rate of technical and biologic complications for cement-retained prostheses. The incidence of technical complications was more dependent upon prosthesis and retention type than prosthesis or abutment material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Little information is yet available on zirconia-based prostheses supported by implants. PURPOSE To evaluate technical problems and failures of implant-supported zirconia-based prostheses with exclusive screw-retention. MATERIAL AND METHODS Consecutive patients received screw-retained zirconia-based prostheses supported by implants and were followed over a time period of 5 years. The implant placement and prosthetic rehabilitation were performed in one clinical setting, and all patients participated in the maintenance program. The treatment comprised single crowns (SCs) and fixed dental prostheses (FDPs) of three to 12 units. Screw-retention of the CAD/CAM-fabricated SCs and FDPs was performed with direct connection at the implant level. The primary outcome was the complete failure of zirconia-based prostheses; outcome measures were fracture of the framework or extensive chipping resulting in the need for refabrication. A life table analysis was performed, the cumulative survival rate (CSR) calculated, and a Kaplan-Meier curve drawn. RESULTS Two hundred and ninety-four implants supported 156 zirconia-based prostheses in 95 patients (52 men, 43 women, average age 59.1 ± 11.7 years). Sixty-five SCs and 91 FDPs were identified, comprising a total of 441 units. Fractures of the zirconia framework and extensive chipping resulted in refabrication of nine prostheses. Nearly all the prostheses (94.2%) remained in situ during the observation period. The 5-year CSR was 90.5%, and 41 prostheses (14 SCs, 27 FDPs) comprising 113 units survived for an observation time of more than 5 years. Six SCs exhibited screw loosening, and polishing of minor chipping was required for five prostheses. CONCLUSIONS This study shows that zirconia-based implant-supported fixed prostheses exhibit satisfactory treatment outcomes and that screw-retention directly at the implant level is feasible.