232 resultados para aorta valve regurgitation
Resumo:
OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).
Resumo:
The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.
Resumo:
Gerbode's defect, a left ventricular-to-right atrial communication, with involvement of the tricuspid valve acquired after bacterial endocarditis can be challenging to repair. We report a modified technique for a shunt closure and reconstruction of the tricuspid valve using a plicated bovine pericardial patch. Combining such a repair with a left ventricular patch resulted in a complete defect closure and competent tricuspid valve without regurgitation.
Resumo:
Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.
Resumo:
It is not well known if the size of the ascending thoracic aorta at presentation predicts features of presentation, management, and outcomes in patients with acute type B aortic dissection. The International Registry of Acute Aortic Dissection (IRAD) database was queried for all patients with acute type B dissection who had documentation of ascending thoracic aortic size at time of presentation. Patients were categorized according to ascending thoracic aortic diameters ≤4.0, 4.1 to 4.5, and ≥4.6 cm. Four hundred eighteen patients met inclusion criteria; 291 patients (69.6%) were men with a mean age of 63.2 ± 13.5 years. Ascending thoracic aortic diameter ≤4.0 cm was noted in 250 patients (59.8%), 4.1 to 4.5 cm in 105 patients (25.1%), and ≥4.6 cm in 63 patients (15.1%). Patients with an ascending thoracic aortic diameter ≥4.6 cm were more likely to be men (p = 0.01) and have Marfan syndrome (p <0.001) and known bicuspid aortic valve disease (p = 0.003). In patients with an ascending thoracic aorta ≥4.1 cm, there was an increased incidence of surgical intervention (p = 0.013). In those with an ascending thoracic aorta ≥4.6 cm, the root, ascending aorta, arch, and aortic valve were more often involved in surgical repair. Patients with an ascending thoracic aorta ≤4.0 were more likely to have endovascular therapy than those with larger ascending thoracic aortas (p = 0.009). There was no difference in overall mortality or cause of death. In conclusion, ascending thoracic aortic enlargement in patients with acute type B aortic dissection is common. Although its presence does not appear to predict an increased risk of mortality, it is associated with more frequent open surgical intervention that often involves replacement of the proximal aorta. Those with smaller proximal aortas are more likely to receive endovascular therapy.
Resumo:
Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.
Resumo:
A 77-year-old woman underwent aortic valve replacement and coronary bypass grafting in 2007 in the Emirates. Evolution was uneventful until December 2011. After repeated episodes of unspecific infections, a computed tomographic scan showed a large pseudoaneurysm of the distal ascending aorta. The site of aortic rupture was closed with a Gore-Tex patch and a Staphylococcus aureus infection treated appropriately. Two months later, a small cutaneous lesion on the cranial part of the sternotomy started bleeding. Computed tomographic scan demonstrated recurrence of a false aneurysm with erosion of the sternum and a large subcutaneous hematoma caused by the fistula. The patient was transferred to our institution. The challenges of this case included safe surgical approach (sternotomy, cannulation, perfusion, cerebral protection) as well as complete removal and extensive debridement of the infected material and reconstruction of the aortic arch. Using fully biological material, reconstruction of the ascending aorta and proximal arch was successfully performed.
Resumo:
In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.
Resumo:
A 49-year-old male patient presented with a paravalvular leakage 18 years after aortic valve replacement. The patient received a mechanical valve and was weaned uneventfully from cardiopulmonary bypass. After a drop in the pressure curve of the left radial artery an additional line was placed in the proximal ascending aorta showing normal systemic pressure. Transesophageal echocardiography showed a massive circular thrombosis of the distal aortic arch. The patient received a covered stent to expand the residual aortic lumen and left the hospital in good health.
Resumo:
OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.