55 resultados para Valves.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The characteristic features of Whipple's disease include abdominal pain, diarrhoea, wasting, and arthralgias, with the causative agent, Tropheryma whipplei, being detected mainly in intestinal biopsies. PCR technology has led to the identification of T. whipplei in specimens from various other locations, including the central nervous system and the heart. T. whipplei is now recognized as one of the causes of culture-negative endocarditis, and endocarditis can be the only manifestation of the infection with T. whipplei. Although it is considered a rare disease, the true incidence of endocarditis due to T. whipplei is not clearly established. With the increasing use of molecular methods, it is likely that T. whipplei will be more frequently identified. Questions also remain about the genetic variability of T. whipplei strains, optimal diagnostic procedures and therapeutic options. In the present study, we provide clinical data on four new patients with documented endocarditis due to T. whipplei in the context of the available published literature. There was no clinical involvement of the gastrointestinal tract. Genetic analysis of the T. whipplei strains with DNA isolated from the excised heart valves revealed little to no genetic variability. In a selected case, we describe acridine orange staining for early detection of the disease, prompting early adaptation of the antibiotic therapy. We provide long-term follow-up data on the patients. In our hands, an initial 2-week course of intravenous antibiotics followed by cotrimoxazole for at least 1 year was a suitable treatment option for T. whipplei endocarditis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiac papillary fibroelastoma is a benign tumor that mainly affects cardiac valves. The tumor has the potential to cause angina and myocardial infarction due to embolization of tumor fragments. We describe a rare case of right coronary artery ostial obstruction by a 12 x 19 mm sized papillary fibroelastoma located in the sinus of Valsalva. The report underlies the importance of echocardiography in diagnosis and intraoperative treatment of this type of cardiac mass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sinotubular junction dilation is one of the most frequent pathologies associated with aortic root incompetence. Hence, we create a finite element model considering the whole root geometry; then, starting from healthy valve models and referring to measures of pathological valves reported in the literature, we reproduce the pathology of the aortic root by imposing appropriate boundary conditions. After evaluating the virtual pathological process, we are able to correlate dimensions of non-functional valves with dimensions of competent valves. Such a relation could be helpful in recreating a competent aortic root and, in particular, it could provide useful information in advance in aortic valve sparing surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Giulio Cesare Aranzio in Italian (Julius Caesar Arantius in Latin) has not received full acclaim for his achievements in the field of anatomy and surgery that remain unknown to most physicians. His anatomical books Observationes Anatomicas, and De Humano Foetu Opusculum and surgical books De Tumoribus Secundum Locos Affectos and Hippocratis librum de vulneribus capitis commentarius brevis printed in Latin and additional existing literature on Aranzio from medical history books and journals were analysed extensively. Aranzio became Professor of Anatomy and Surgery at the University of Bologna in 1556. He established anatomy as a distinguished branch of medicine for the first time in medical history. Aranzio combined anatomy with a description of pathological processes. He discovered the 'Nodules of Aranzio' in the semilunar valves of the heart. He gave the first description of the superior levator palpebral and the coracobrachialis muscles. Aranzio wrote on surgical techniques for a wide spectrum of conditions that range from hydrocephalus, nasal polyp, goitre and tumours to phimosis, ascites, haemorrhoids, anal abscess and fistulae, and much more. Aranzio had an extensive knowledge in surgery and anatomy based in part on the ancient Greek and his contemporaries in the 16th century but essentially on his personal experience and practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New anticoagulants promise to have better efficacy, more safety and/or a better manageability than traditional anticoagulants. However, knowledge is limited regarding special situations such as renal insufficiency, obesity, pregnancy, long-term therapy, heparin-induced thrombocytopenia, treatment in patients with mechanical heart valves, use for children, and in patients with a high risk of thromboembolic complications. These situations have rarely or even never been the objective of randomised controlled trials. The purpose of the present article is to summarize and discuss available data on efficacy and safety in these special situations for one of the first new anticoagulants, the indirect factor-Xa inhibitor fondaparinux. Furthermore, we discuss safety in licensed indications and management of bleeding complications and comment on measuring of drug concentration in plasma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is rapidly evolving as an alternative treatment option for elderly patients with severe symptomatic aortic stenosis and excessive risk for surgical intervention. Transcatheter valve-in-valve implantation is an alternative approach to redo-surgery for patients with degeneration of a bioprosthetic valve. Herein are reported three cases of successful transcatheter aortic valve-in-valve implantation for severely regurgitant bioprosthetic valves with a clinical follow up of more than 12 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The ultrastructure of venous valves and walls in chronic venous disease was investigated. METHODS: Consecutive patients were categorised into one of three groups (group A: patients with C1 venous disease in accordance with CEAP (Clinical severity, Etiology, Anatomy, Pathophysiology); group B: C2 and C3; group C: C4, C5 and C6). The terminal or preterminal valve and adjacent vessel wall was harvested from the great saphenous vein. Sections were examined with a transmission electron microscope. The volumes of elastin and of collagen per unit surface area of valve were assessed, as well as the surface endothelium of valve and vessel wall. RESULTS: The study population consisted of 17 patients. The elastin ratio was analysed by means of stereology. Mean values were: in group A, 0.45 μm3/m2; in group B, 0.67 μm3/m2; in group C, 0.97 μm3/m2. The ratio was similar for collagen (A, 15.7 μm3/m2; B, 26.8 μm3/m2; C, 30.1 μm3/m2). Surface analysis of the valve endothelium and the adjacent vessel wall endothelium showed a trend towards increasing damage with more severe disease. CONCLUSIONS: With progression of venous disease, the valve elastin content, assessed morphologically, seems to increase, and the endothelium of the venous valve and the vein wall tend to show more damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study sought to report on the pathology of transcatheter aortic valves explanted at early and late time points after transcatheter aortic valve implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.