57 resultados para VALIDITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary aim was to examine the utility of DSM-IV criteria in predicting treatment outcome in a sample of adolescents with eating disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To examine the validity of multi-fiber muscle velocity recovery cycles (VRCs) recorded by direct muscle stimulation with submaximal stimuli.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient-orientated outcome questionnaires are essential to evaluate treatment success. To compare different treatments, hospitals, and surgeons, standardised questionnaires are required. The present study examined the validity and responsiveness of the Core Outcome Measurement Index for neck pain (COMI-neck), a short, multidimensional outcome instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Basic symptom (BS) criteria have been suggested to complement ultra-high risk (UHR) criteria in the early detection of psychosis in adults and in children and adolescents. To account for potential developmental particularities and a different clustering of BS in children and adolescents, the Schizophrenia Proneness Instrument, Child and Youth version (SPI-CY) was developed. Aims The SPI-CY was evaluated for its practicability and discriminative validity. Method The SPI-CY was administered to 3 groups of children and adolescents (mean age 16; range=8–18; 61% male): 23 at-risk patients meeting UHR and/or BS criteria (AtRisk), 22 clinical controls (CC), and 19 children and adolescents from the general population (GPS) matched to AtRisk in age, gender, and education. We expected AtRisk to score highest on the SPI-CY, and GPS lowest. Results The groups differed significantly on all 4 SPI-CY subscales. Pairwise post-hoc comparisons confirmed our expectations for all subscales and, at least on a descriptive level, most items. Pairwise subscale differences indicated at least moderate group effects (r≥0.37) which were largest for Adynamia (0.52≤r≥0.70). Adynamia also performed excellent to outstanding in ROC analyses (0.813≤AUC≥0.981). Conclusion The SPI-CY could be a helpful tool for detecting and assessing BS in the psychosis spectrum in children and adolescents, by whom it was well received. Furthermore, its subscales possess good discriminative validity. However, these results require validation in a larger sample, and the psychosis-predictive ability of the subscales in different age groups, especially the role of Adynamia, will have to be explored in longitudinal studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Methods Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. Results All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. Conclusions The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this paper was to review the clinical literature on the Resonance frequency analysis (RFA) and Periotest techniques in order to assess the validity and prognostic value of each technique to detect implants at risk for failure. Material and methods: A search was made using the PubMed database to find clinical studies using the RFA and/or Periotest techniques. Results: A limited number of clinical reports were found. No randomized-controlled clinical trials or prospective cohort studies could be found for validity testing of the techniques. Consequently, only a narrative review was prepared to cover general aspects of the techniques, factors influencing measurements and the clinical relevance of the techniques. Conclusions: Factors such as bone density, upper or lower jaw, abutment length and supracrestal implant length seem to influence both RFA and Periotest measurements. Data suggest that high RFA and low Periotest values indicate successfully integrated implants and that low/decreasing RFA and high/increasing Periotest values may be signs of ongoing disintegration and/or marginal bone loss. However, single readings using any of the techniques are of limited clinical value. The prognostic value of the RFA and Periotest techniques in predicting loss of implant stability has yet to be established in prospective clinical studies. To cite this article: Aparicio C, Lang N P, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin. Oral Imp. Res., 17 (Suppl. 2), 2006; 2-7.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study is to assess the structural and cross-cultural validity of the KIDSCREEN-27 questionnaire. METHODS: The 27-item version of the KIDSCREEN instrument was derived from a longer 52-item version and was administered to young people aged 8-18 years in 13 European countries in a cross-sectional survey. Structural and cross-cultural validity were tested using multitrait multi-item analysis, exploratory and confirmatory factor analysis, and Rasch analyses. Zumbo's logistic regression method was applied to assess differential item functioning (DIF) across countries. Reliability was assessed using Cronbach's alpha. RESULTS: Responses were obtained from n = 22,827 respondents (response rate 68.9%). For the combined sample from all countries, exploratory factor analysis with procrustean rotations revealed a five-factor structure which explained 56.9% of the variance. Confirmatory factor analysis indicated an acceptable model fit (RMSEA = 0.068, CFI = 0.960). The unidimensionality of all dimensions was confirmed (INFIT: 0.81-1.15). Differential item functioning (DIF) results across the 13 countries showed that 5 items presented uniform DIF whereas 10 displayed non-uniform DIF. Reliability was acceptable (Cronbach's alpha = 0.78-0.84 for individual dimensions). CONCLUSIONS: There was substantial evidence for the cross-cultural equivalence of the KIDSCREEN-27 across the countries studied and the factor structure was highly replicable in individual countries. Further research is needed to correct scores based on DIF results. The KIDSCREEN-27 is a new short and promising tool for use in clinical and epidemiological studies.