115 resultados para Upper semicontinuity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is paucity of data on bacillus Calmette-Guérin (BCG) perfusion in patients with non-muscle-invasive urothelial carcinoma (NMIUC) of the upper urinary tract (UUT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin cancer of the lip is frequent, and reconstruction after Mohs surgery might be challenging mostly when the postsurgical defect has a size of more than 1 cm(2) and is situated adjacent to the philtrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain mechanisms associated with artistic talents or skills are still not well understood. This exploratory study investigated differences in brain activity of artists and non-artists while drawing previously presented perspective line-drawings from memory and completing other drawing-related tasks. Electroencephalography (EEG) data were analyzed for power in the frequency domain by means of a Fast Fourier Transform (FFT). Low Resolution Brain Electromagnetic Tomography (LORETA) was applied to localize emerging significances. During drawing and related tasks, decreased power was seen in artists compared to non-artists mainly in upper alpha frequency ranges. Decreased alpha power is often associated with an increase in cognitive functioning and may reflect enhanced semantic memory performance and object recognition processes in artists. These assumptions are supported by the behavioral data assessed in this study and complement previous findings showing increased parietal activations in non-artists compared to artists while drawing. However, due to the exploratory nature of the analysis, additional confirmatory studies will be needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extension of 3-D atmospheric data products back into the past is desirable for a wide range of applications. Historical upper-air data are important in this endeavour, particularly in the maritime regions of the tropics and the southern hemisphere, where observations are extremely sparse. Here we present newly digitized and re-evaluated early ship-based upper-air data from two cruises: (1) kite and registering balloon profiles from onboard the ship SMS Planet on a cruise from Europe around South Africa and across the Indian Ocean to the western Pacific in 1906/1907, and (2) ship-based radiosonde data from onboard the MS Schwabenland on a cruise from Europe across the Atlantic to Antarctica and back in 1938/1939. We describe the data and provide estimations of the errors. We compare the data with a recent reanalysis (the Twentieth Century Reanalysis Project, 20CR, Compo et al., 2011) that provides global 3-D data back to the 19th century based on an assimilation of surface pressure data only (plus monthly mean sea-surface temperatures). In cruise (1), the agreement is generally good, but large temperature differences appear during a period with a strong inversion. In cruise (2), after a subset of the data are corrected, close agreement between observations and 20CR is found for geopotential height (GPH) and temperature notwithstanding a likely cold bias of 20CR at the tropopause level. Results are considerably worse for relative humidity, which was reportedly inaccurately measured. Note that comparing 20CR, which has limited skill in the tropical regions, with measurements from ships in remote regions made under sometimes difficult conditions can be considered a worst case assessment. In view of that fact, the anomaly correlations for temperature of 0.3–0.6 in the lower troposphere in cruise (1) and of 0.5–0.7 for tropospheric temperature and GPH in cruise (2) are considered as promising results. Moreover, they are consistent with the error estimations. The results suggest room for further improvement of data products in remote regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thromboangiitis obliterans (Buerger's disease) is a rare, non-atherosclerotic, segmental, inflammatory vasculitis that most commonly involves small and medium-sized arteries, veins and nerves of the extremities and affects tobacco smokers between the ages of 25 and 45 years. The manifestations of Buerger's disease can be extremely variable and, therefore, awareness of the condition is important for both general and musculoskeletal radiologists. This paper presents the radiological appearance of the sequelae of Buerger's disease involving the upper and lower limbs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the clinical outcome of a 46-year-old man referred for percutaneous closure of an atrial septal defect under transthoracic echocardiographic and fluoroscopic guidance, whose upper left pulmonary vein was erroneously obliterated using an Amplatzer atrial septal defect occluder. Various medical conditions have been associated with pulmonary vein stenosis including dyspnea on exertion or at rest, cough, and hemoptysis. However, there were no short- or long-term symptoms in this patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. Aim: Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. Methods: Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. Results: Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. Conclusions: In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.