40 resultados para Uniform Rotundity In Every Direction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lung cancer is the leading cause of cancer death worldwide. The overall 5-year survival after therapy is about 16% and there is a clear need for better treatment options, such as therapies targeting specific molecular structures. G-protein coupled receptors (GPCRs), as the largest family of cell surface receptors, represent an important group of potential targets for diagnostics and therapy. We therefore used laser capture microdissection and GPCR-focused Affymetrix microarrays to examine the expression of 929 GPCR transcripts in tissue samples of 10 patients with squamous cell carcinoma and 7 with adenocarcinoma in order to identify novel targets in non-small cell lung carcinoma (NSCLC). The relative gene expression levels were calculated in tumour samples compared to samples of the neighbouring alveolar tissue in every patient. Based on this unique study design, we identified 5 significantly overexpressed GPCRs in squamous cell carcinoma, in the following decreasing order of expression: GPR87 > CMKOR1 > FZD10 > LGR4 > P2RY11. All are non-olfactory and GRAFS (glutamate, rhodopsin, adhesion, frizzled/taste2, secretin family) classified. GPR87, LGR4 and CMKOR1 are orphan receptors. GPR87 stands out as a candidate for further target validation due to its marked overexpression and correlation on a mutation-based level to squamous cell carcinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research in autophagy continues to accelerate,(1) and as a result many new scientists are entering the field. Accordingly, it is important to establish a standard set of criteria for monitoring macroautophagy in different organisms. Recent reviews have described the range of assays that have been used for this purpose.(2,3) There are many useful and convenient methods that can be used to monitor macroautophagy in yeast, but relatively few in other model systems, and there is much confusion regarding acceptable methods to measure macroautophagy in higher eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers of autophagosomes versus those that measure flux through the autophagy pathway; thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from fully functional autophagy that includes delivery to, and degradation within, lysosomes (in most higher eukaryotes) or the vacuole (in plants and fungi). Here, we present a set of guidelines for the selection and interpretation of the methods that can be used by investigators who are attempting to examine macroautophagy and related processes, as well as by reviewers who need to provide realistic and reasonable critiques of papers that investigate these processes. This set of guidelines is not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to verify an autophagic response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the steady-state function of the ubiquitous mammalian Na/H exchanger (NHE)1 isoform in voltage-clamped Chinese hamster ovary cells, as well as other cells, using oscillating pH-sensitive microelectrodes to quantify proton fluxes via extracellular pH gradients. Giant excised patches could not be used as gigaseal formation disrupts NHE activity within the patch. We first analyzed forward transport at an extracellular pH of 8.2 with no cytoplasmic Na (i.e., nearly zero-trans). The extracellular Na concentration dependence is sigmoidal at a cytoplasmic pH of 6.8 with a Hill coefficient of 1.8. In contrast, at a cytoplasmic pH of 6.0, the Hill coefficient is <1, and Na dependence often appears biphasic. Results are similar for mouse skin fibroblasts and for an opossum kidney cell line that expresses the NHE3 isoform, whereas NHE1(-/-) skin fibroblasts generate no proton fluxes in equivalent experiments. As proton flux is decreased by increasing cytoplasmic pH, the half-maximal concentration (K(1/2)) of extracellular Na decreases less than expected for simple consecutive ion exchange models. The K(1/2) for cytoplasmic protons decreases with increasing extracellular Na, opposite to predictions of consecutive exchange models. For reverse transport, which is robust at a cytoplasmic pH of 7.6, the K(1/2) for extracellular protons decreases only a factor of 0.4 when maximal activity is decreased fivefold by reducing cytoplasmic Na. With 140 mM of extracellular Na and no cytoplasmic Na, the K(1/2) for cytoplasmic protons is 50 nM (pH 7.3; Hill coefficient, 1.5), and activity decreases only 25% with extracellular acidification from 8.5 to 7.2. Most data can be reconstructed with two very different coupled dimer models. In one model, monomers operate independently at low cytoplasmic pH but couple to translocate two ions in "parallel" at alkaline pH. In the second "serial" model, each monomer transports two ions, and translocation by one monomer allosterically promotes translocation by the paired monomer in opposite direction. We conclude that a large fraction of mammalian Na/H activity may occur with a 2Na/2H stoichiometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: In order to use a single implant with one treatment plan in fractionated high-dose-rate brachytherapy (HDR-B), applicator position shifts must be corrected prior to each fraction. The authors investigated the use of gold markers for X-ray-based setup and position control between the single fractions. PATIENTS AND METHODS: Caudad-cephalad movement of the applicators prior to each HDR-B fraction was determined on radiographs using two to three gold markers, which had been inserted into the prostate as intraprostatic reference, and one to two radiopaque-labeled reference applicators. 35 prostate cancer patients, treated by HDR-B as a monotherapy between 10/2003 and 06/2006 with four fractions of 9.5 Gy each, were analyzed. Toxicity was scored according to the CTCAE Score, version 3.0. Median follow-up was 3 years. RESULTS: The mean change of applicators positions compared to baseline varied substantially between HDR-B fractions, being 1.4 mm before fraction 1 (range, -4 to 2 mm), -13.1 mm before fraction 2 (range, -36 to 0 mm), -4.1 mm before fraction 3 (range, -21 to 9 mm), and -2.6 mm at fraction 4 (range, -16 to 9 mm). The original position of the applicators could be readjusted easily prior to each fraction in every patient. In 18 patients (51%), the applicators were at least once readjusted > 10 mm, however, acute or late grade > or = 2 genitourinary toxicity was not increased (p = 1.0) in these patients. CONCLUSION: Caudad position shifts up to 36 mm were observed. Gold markers represent a valuable tool to ensure setup accuracy and precise dose delivery in fractionated HDR-B monotherapy of prostate cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Current guidelines for the management of acute coronary syndrome clearly recommend that clopidogrel should be started before diagnostic coronary angiography. If patients undergo coronary artery bypass grafting (CABG) early after clopidogrel loading or during continued exposure, it seems reasonable to expect an increase in bleeding complications. RECENT FINDINGS: Earlier studies may have overestimated the risk of bleeding in patient undergoing CABG with prior clopidogrel exposure (5-10-fold increase). Some conflicting results are reported in literature. As reexploration because of excessive bleeding is concerned, a two to three-fold increase must be expected, which is demonstrated in actual trials properly matched to confounding factors. Discontinuation of clopidogrel for 5-7 days prior to urgent CABG as recommended by guidelines is not well adopted in clinical practice for several reasons. SUMMARY: There is a moderately elevated risk of bleeding complications after CABG due to prior clopidogrel exposure alone. However, in clinical practice this risk is added often to patients who carry already elevated surgical risks (urgent procedures, worse coronary anatomy, history of previous myocardial infarction and prior percutaneous intervention), and after bleeding complications singular patients may suffer from consecutive adverse outcome. Cessation of clopidogrel in patients before CABG clearly prolongs hospitalization time and has an estimated 1% risk of coronary events during the waiting period. Risk and benefit have to be balanced in every individual case.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pathologically elevated body core temperature, measured at the death scene, is an important finding in medico-legal investigation of violent deaths. An abnormally high rectal temperature at any death scene may point to an underlying pathology, the influence of certain drugs or a hidden cerebral traumatism, and death by suffocation which would remain undetected without further medico-legal investigations. Furthermore, hyperthermia and fever, if unrecognized, may result in an erroneous forensic estimation of time since death in the early postmortem period by the "Henssge method." By a retrospective study of 744 cases, the authors demonstrate that hyperthermia is a finding with an incidence of 10% of all cases of violent death. The main causes are: influence of drugs, malignant tumors, cerebral hypoxia as a result of suffocation, infections, and systemic inflammatory disorders. As a consequence it must be stated, that hyperthermia must be excluded in every medico-legal death scene investigation by a correct measurement of body core temperature and a comparison between the cooling rate of the body and the behavior of early postmortem changes, notably livor and rigor mortis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Patients' health related quality of life (HRQoL) has rarely been systematically monitored in general practice. Electronic tools and practice training might facilitate the routine application of HRQoL questionnaires. Thorough piloting of innovative procedures is strongly recommended before the conduction of large-scale studies. Therefore, we aimed to assess i) the feasibility and acceptance of HRQoL assessment using tablet computers in general practice, ii) the perceived practical utility of HRQoL results and iii) to identify possible barriers hindering wider application of this approach. Methods Two HRQoL questionnaires (St. George's Respiratory Questionnaire SGRQ and EORTC QLQ-C30) were electronically presented on portable tablet computers. Wireless network (WLAN) integration into practice computer systems of 14 German general practices with varying infrastructure allowed automatic data exchange and the generation of a printout or a PDF file. General practitioners (GPs) and practice assistants were trained in a 1-hour course, after which they could invite patients with chronic diseases to fill in the electronic questionnaire during their waiting time. We surveyed patients, practice assistants and GPs regarding their acceptance of this tool in semi-structured telephone interviews. The number of assessments, HRQoL results and interview responses were analysed using quantitative and qualitative methods. Results Over the course of 1 year, 523 patients filled in the electronic questionnaires (1–5 times; 664 total assessments). On average, results showed specific HRQoL impairments, e.g. with respect to fatigue, pain and sleep disturbances. The number of electronic assessments varied substantially between practices. A total of 280 patients, 27 practice assistants and 17 GPs participated in the telephone interviews. Almost all GPs (16/17 = 94%; 95% CI = 73–99%), most practice assistants (19/27 = 70%; 95% CI = 50–86%) and the majority of patients (240/280 = 86%; 95% CI = 82–91%) indicated that they would welcome the use of electronic HRQoL questionnaires in the future. GPs mentioned availability of local health services (e.g. supportive, physiotherapy) (mean: 9.4 ± 1.0 SD; scale: 1 – 10), sufficient extra time (8.9 ± 1.5) and easy interpretation of HRQoL results (8.6 ± 1.6) as the most important prerequisites for their use. They believed HRQoL assessment facilitated both communication and follow up of patients' conditions. Practice assistants emphasised that this process demonstrated an extra commitment to patient centred care; patients viewed it as a tool, which contributed to the physicians' understanding of their personal condition and circumstances. Conclusion This pilot study indicates that electronic HRQoL assessment is technically feasible in general practices. It can provide clinically significant information, which can either be used in the consultation for routine care, or for research purposes. While GPs, practice assistants and patients were generally positive about the electronic procedure, several barriers (e.g. practices' lack of time and routine in HRQoL assessment) need to be overcome to enable broader application of electronic questionnaires in every day medical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eye-movement abnormalities in schizophrenia are a well-established phenomenon that has been observed in many studies. In such studies, visual targets are usually presented in the center of the visual field, and the subject's head remains fixed. However, in every-day life, targets may also appear in the periphery. This study is among the first to investigate eye and head movements in schizophrenia by presenting targets in the periphery of the visual field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the introduction of cone beam computed tomography (CBCT), this 3-dimensional diagnostic imaging technique has been established in a growing number of fields in dental medicine. It has become an important tool for both diagnosis and treatment planning, and is also able to support endodontic treatments. However, the higher effective dose of ionizing radiation compared to conventional 2-dimensional radiographs is not justifiable in every case. CBCT allows for a more precise diagnosis of periapical lesions, root fractures as well as external and internal resorptions. Concerning the utility of CBCT in treatment planning decisions, the gain of information through 3-dimensional imaging for any of these pathologies has to be evaluated carefully on an individual basis. Moreover, radioopaque materials such as root canal filling and posts often create artefacts, which may compromise diagnosis. The aim of this review is to summarize the possibilities and limits of CBCT imaging in endodontology as well as introduce guidelines for daily clinical practice. Furthermore, the article presents possible therapeutic advantages of preexisting CBCT scans for root canal treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Chronic pain is associated with generalized hypersensitivity and impaired endogenous pain modulation (conditioned pain modulation; CPM). Despite extensive research, their prevalence in chronic pain patients is unknown. This study investigated the prevalence and potential determinants of widespread central hypersensitivity and described the distribution of CPM in chronic pain patients. METHODS We examined 464 consecutive chronic pain patients for generalized hypersensitivity and CPM using pressure algometry at the second toe and cold pressor test. Potential determinants of generalized central hypersensitivity were studied using uni- and multivariate regression analyses. Prevalence of generalized central hypersensitivity was calculated for the 5th, 10th and 25th percentile of normative values for pressure algometry obtained by a previous large study on healthy volunteers. CPM was addressed on a descriptive basis, since normative values are not available. RESULTS Depending on the percentile of normative values considered, generalized central hypersensitivity affected 17.5-35.3% of patients. 23.7% of patients showed no increase in pressure pain threshold after cold pressor test. Generalized central hypersensitivity was more frequent and CPM less effective in women than in men. Unclearly classifiable pain syndromes showed higher frequencies of generalized central hypersensitivity than other pain syndromes. CONCLUSIONS Although prevalent in chronic pain, generalized central hypersensitivity is not present in every patient. An individual assessment is therefore required in order to detect altered pain processing. The broad basic knowledge about central hypersensitivity now needs to be translated into concrete clinical consequences, so that patients can be offered an individually tailored mechanism-based treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital analysis of the occlusal contacts can be performed with the T-scan device (T Scan III, TekScan, Boston, USA). However, the thickness of the interocclusal T-scan sheet (100 μm) may lead to a displacement of the mandible. Thus, the aim of this study was to investigate the impact of the T-scan sheet on the position of the mandibular condyles in maximum intercuspidation. Twenty dentate subjects with healthy jaw function were enrolled in the study. An ultrasonic axiography device was used to measure the position of the condyles. Ten 3D condyle positions in maximum intercuspidation of the teeth were recorded: first the reference position without the sheet, then 3 times without the sheet, 3 times with the sheet, and finally again 3 times without the sheet. There was a statistically significant difference (Wilcoxon matched pairs test) between the condyle positions with and without the interocclusally positioned T-scan sheet (P < 0.0005). The T-scan device lead to a displacement of the condyles of about 1 mm mainly in ventral direction (P = 0.005). Thus, occlusal analysis is not performed in physiological, maximum intercuspidation. This has to be considered when interpreting the measured contact points.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe long-term follow-up and difference in immune reactions in the tear film following penetrating keratoplasty (PK) in horses when differently preserved corneas were utilised. This report describes for the first time the use of corneal grafts preserved in tissue culture media in equine PK. Eight experimental horses with normal eyes were included and freshly harvested, frozen or preserved corneal grafts were used for the PK. The graft-taking technique and storage, PK surgery, postoperative treatments and complications are described. The mean postoperative follow-up time was 286 days. Tear film samples taken before and periodically after surgery were measured for IgM, IgG and IgA contents by direct ELISA. All grafts were incorporated into the donor horse but were rejected to some degree. The differently harvested corneal grafts healed in the same manner and looked similar. Preoperatively, the clear corneas meant low risk for graft failure, and the fresh or stored tissues provided intact endothelium, although there were no clear graft sites postoperatively. The presence of IgA, IgG and IgM was demonstrated in the tear film from the early postoperative period. IgG levels were lower than IgA or IgM and had a constant baseline in every case, as IgA and IgM had great variability with time and an individual pattern in each eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The combination of scaled analogue experiments, material mechanics, X-ray computed tomography (XRCT) and Digital Volume Correlation techniques (DVC) is a powerful new tool not only to examine the 3 dimensional structure and kinematic evolution of complex deformation structures in scaled analogue experiments, but also to fully quantify their spatial strain distribution and complete strain history. Digital image correlation (DIC) is an important advance in quantitative physical modelling and helps to understand non-linear deformation processes. Optical non-intrusive (DIC) techniques enable the quantification of localised and distributed deformation in analogue experiments based either on images taken through transparent sidewalls (2D DIC) or on surface views (3D DIC). X-ray computed tomography (XRCT) analysis permits the non-destructive visualisation of the internal structure and kinematic evolution of scaled analogue experiments simulating tectonic evolution of complex geological structures. The combination of XRCT sectional image data of analogue experiments with 2D DIC only allows quantification of 2D displacement and strain components in section direction. This completely omits the potential of CT experiments for full 3D strain analysis of complex, non-cylindrical deformation structures. In this study, we apply digital volume correlation (DVC) techniques on XRCT scan data of “solid” analogue experiments to fully quantify the internal displacement and strain in 3 dimensions over time. Our first results indicate that the application of DVC techniques on XRCT volume data can successfully be used to quantify the 3D spatial and temporal strain patterns inside analogue experiments. We demonstrate the potential of combining DVC techniques and XRCT volume imaging for 3D strain analysis of a contractional experiment simulating the development of a non-cylindrical pop-up structure. Furthermore, we discuss various options for optimisation of granular materials, pattern generation, and data acquisition for increased resolution and accuracy of the strain results. Three-dimensional strain analysis of analogue models is of particular interest for geological and seismic interpretations of complex, non-cylindrical geological structures. The volume strain data enable the analysis of the large-scale and small-scale strain history of geological structures.