94 resultados para Total Hip Prosthesis
Resumo:
INTRODUCTION: We report the results of a titanium acetabular reinforcement ring with a hook (ARRH) in primary total hip arthroplasty (THA), which was introduced in 1987 and continues to be used routinely in our center. The favorable results of this device in arthroplasty for developmental dysplasia and difficult revisions motivated its use in primary THA. With this implant only minimal acetabular reaming is necessary, anatomic positioning is achieved by placing the hook around the teardrop and a homogenous base for cementing the polyethylene cup is provided. MATERIALS AND METHODS: Between April 1987 and December 1991, 241 THAs with insertion of an ARRH were performed in 178 unselected, consecutive patients (average age 58 years; range 30-84 years) with a secondary osteoarthrosis in 41% of the cases. RESULTS: At the time of the latest follow-up, 33 patients (39 hips) had died and 17 cases had been lost to follow-up. The median follow-up was 122 months with a minimum of 10 years. Eight hips had been revised, leaving 177 hips in 120 living patients without revision. Six cups were revised because of aseptic loosening. Two hips were revised for sepsis. The mean Merle d'Aubigné score for the remaining hips was 16 (range 7-18) at the latest follow-up. For aseptic loosening, the probability of survival of the cup was 0.97 (95% confidence interval, 0.94-0.99). However, analysis of radiographs implied loosening in seven other cups without clinical symptoms. CONCLUSIONS: The results of primary THA using an acetabular reinforcement ring parallel the excellent results of these implants often observed in difficult primary and revision arthroplasty at a minimum of 10 years. Survivorship is comparable to modern cementless implants. Medial migration that occurs with loosening of the acetabular component seems to be prevented with this implant. Radiographic loosening signs can exist without clinical symptoms.
Resumo:
BACKGROUND While surgical navigation offers the opportunity to accurately place an acetabular component, questions remain as to the best goal for acetabular component positioning in individual patients. Overall functional orientation of the pelvis after surgery is one of the most important variables for the surgeon to consider when determining the proper goal for acetabular component orientation. QUESTIONS/PURPOSES We measured the variation in pelvic tilt in 30 patients before THA and the effect of THA on pelvic tilt in the same patients more than a year after THA. METHODS Each patient had a CT study for CT-based surgical navigation and standing and supine radiographs before and after surgery. Pelvic tilt was calculated for each of the radiographs using a novel and validated two-dimensional/three-dimensional matching technique. RESULTS Mean supine pelvic tilt changed less than 2°, from 4.4° ± 6.4° (range, -7.7° to 20.8°) before THA to 6.3° ± 6.6° (range, -5.7° to 19.6°) after THA. Mean standing pelvic tilt changed less than 1°, from 1.5° ± 7.2° (range, -13.1° to 12.8°) before THA to 2.0° ± 8.3° (range, -12.3° to 16.8°) after THA. Preoperative pelvic tilt correlated with postoperative tilt in both the supine (r(2) = 0.75) and standing (r(2) = 0.87) positions. CONCLUSIONS In this population, pelvic tilt had a small and predictable change after surgery. However, intersubject variability of pelvic tilt was high, suggesting preoperative pelvic tilt should be considered when determining desired acetabular component positioning on a patient-specific basis.
Resumo:
Background: The published data on pain and physical function before and after revision of total hip arthroplasty (THA) is scarce. The study reports the course and interrelationships of radiographic loosening, pain and physical function 5 year before and after a first revision THA. Methods: The study was based on the IDES-THA database. All patients with their first THA revision for aseptic loosening and a documented index surgery on the same side and at least one pre-revision and one post-revision follow-up were selected. Only patients with an intact contralateral hip joint (Charnley class-A) were included. Follow-ups within ±5.5 years around the revision time point were analyzed. Annual prevalences of radiographic component loosening and the non-desired outcomes (moderate/severe/intolerable pain, walking <30 minutes, hip flexion range <90°) were calculated. Results: Signs of radiographic component loosening started to increase about 4 years before revision surgery. Two years later, a sharp increase of painful hips from 15% to 80% in the revision year was observed. In the year after revision surgery, this rate dropped back to below 10%. Walking capacity started to noticeably deteriorate 3 years before revision and in the revision year about 65% of patients could not walk longer than 30 minutes. As opposed to pain, walking capacity did not recover to pre-revision levels and the best outcome was only reached two years post-revision. Hip flexion range had the slowest and least extent of deterioration (≈45% flexed <70° in the revision year) but with the best outcomes at only three years after revision surgery it took the longest to recover. Conclusion: Prevalence of radiological loosening signs and/or pain intensity follow an almost parallel course around the first revision of a THA for aseptic component loosening. This process begins about 4 years (radiographic loosening) before the actual revision surgery and intensifies about 2 years later (pain). It also involves walking capacity and hip range of motion. While pain levels go back to levels similar to those after primary surgery, range of motion and even more walking capacity remain moderately compromised.
Resumo:
Purpose Malposition of the acetabular component in total hip arthroplasty (THA) is a common surgical problem that can lead to hip dislocation, reduced range of motion and may result in early loosening. The aim of this study is to validate the accuracy and reproducibility of a single x-ray image based 2D/3D reconstruction technique in determining cup inclination and anteversion against two different computer tomography (CT)-based measurement techniques. Methods Cup anteversion and inclination of 20 patients after cementless primary THA was measured on standard anteroposterior (AP) radiographs with the help of the single x-ray 2D/3D reconstruction program and compared with two different 3D CT-based analyses [Ground Truth (GT) and MeVis (MV) reconstruction model]. Results The measurements from the single x-ray 2D/3D reconstruction technique were strongly correlated with both types of CT image-processing protocols for both cup inclination [R²=0.69 (GT); R²=0.59 (MV)] and anteversion [R²=0.89 (GT); R²=0.80 (MV)]. Conclusions The single x-ray image based 2D/3D reconstruction technique is a feasible method to assess cup position on postoperative x-rays. CTscans remain the golden standard for a more complex biomechanical evaluation when a lower tolerance limit (+/-2 degrees) is required.
Resumo:
Background Complete-pelvis segmentation in antero-posterior pelvic radiographs is required to create a patient-specific three-dimensional pelvis model for surgical planning and postoperative assessment in image-free navigation of total hip arthroplasty. Methods A fast and robust framework for accurately segmenting the complete pelvis is presented, consisting of two consecutive modules. In the first module, a three-stage method was developed to delineate the left hemipelvis based on statistical appearance and shape models. To handle complex pelvic structures, anatomy-specific information processing techniques were employed. As the input to the second module, the delineated left hemi-pelvis was then reflected about an estimated symmetry line of the radiograph to initialize the right hemi-pelvis segmentation. The right hemi-pelvis was segmented by the same three-stage method, Results Two experiments conducted on respectively 143 and 40 AP radiographs demonstrated a mean segmentation accuracy of 1.61±0.68 mm. A clinical study to investigate the postoperative assessment of acetabular cup orientations based on the proposed framework revealed an average accuracy of 1.2°±0.9° and 1.6°±1.4° for anteversion and inclination, respectively. Delineation of each radiograph costs less than one minute. Conclusions Despite further validation needed, the preliminary results implied the underlying clinical applicability of the proposed framework for image-free THA.
Resumo:
BACKGROUND Many orthopaedic surgical procedures can be performed with either regional or general anesthesia. We hypothesized that total hip arthroplasty with regional anesthesia is associated with less postoperative morbidity and mortality than total hip arthroplasty with general anesthesia. METHODS This retrospective propensity-matched cohort study utilizing the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database included patients who had undergone total hip arthroplasty from 2007 through 2011. After matching, logistic regression was used to determine the association between the type of anesthesia and deep surgical site infections, hospital length of stay, thirty-day mortality, and cardiovascular and pulmonary complications. RESULTS Of 12,929 surgical procedures, 5103 (39.5%) were performed with regional anesthesia. The adjusted odds for deep surgical site infections were significantly lower in the regional anesthesia group than in the general anesthesia group (odds ratio [OR] = 0.38; 95% confidence interval [CI] = 0.20 to 0.72; p < 0.01). The hospital length of stay (geometric mean) was decreased by 5% (95% CI = 3% to 7%; p < 0.001) with regional anesthesia, which translates to 0.17 day for each total hip arthroplasty. Regional anesthesia was also associated with a 27% decrease in the odds of prolonged hospitalization (OR = 0.73; 95% CI = 0.68 to 0.89; p < 0.001). The mortality rate was not significantly lower with regional anesthesia (OR = 0.78; 95% CI = 0.43 to 1.42; p > 0.05). The adjusted odds for cardiovascular complications (OR = 0.61; 95% CI = 0.44 to 0.85) and respiratory complications (OR = 0.51; 95% CI = 0.33 to 0.81) were all lower in the regional anesthesia group. CONCLUSIONS Compared with general anesthesia, regional anesthesia for total hip arthroplasty was associated with a reduction in deep surgical site infection rates, hospital length of stay, and rates of postoperative cardiovascular and pulmonary complications. These findings could have an important medical and economic impact on health-care practice.
Resumo:
This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.
Resumo:
Pelvic discontinuity is a complex problem in revision total hip arthroplasty. Although rare, the incidence is likely to increase due to the ageing population and the increasing number of total hip arthroplasties being performed. The various surgical options available to solve this problem include plating, massive allografts, reconstruction rings, custom triflanged components and tantalum implants. However, the optimal solution remains controversial. None of the known methods completely solves the major obstacles associated with this problem, such as restoration of massive bone loss, implant failure in the short- and long-term and high complication rates. This review discusses the diagnosis, decision making, and treatment options of pelvic discontinuity in revision total hip arthroplasty.
Resumo:
PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.
Resumo:
INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.