51 resultados para The performance of Christian and pagan storyworlds
Resumo:
Introduction: The aim of the present work was to verify whether calculating a ratio between clotting times obtained with the sensitive PTT-LA and a less sensitive activated partial thromboplastin time (aPTT)-reagent may represent a valuable aPTT-based screening strategy for lupus anticoagulants (LA). Methods: For the pilot study, plasma samples from normal subjects (n = 15) and from patients with LA (n = 10), therapeutic anticoagulation with vitamin K-antagonists (VKA) (n = 15) or unfractionated heparin (n = 15), coagulation factors deficiency (n = 16), and inhibitory antibodies against factor VIII or IX (n = 11) were studied. For the evaluation study, 1553 consecutive plasma samples from nonanticoagulated patients investigated for LA between January 2005 and December 2007 at our institution were studied. Following screening strategies were employed: Pathromtin-SL (aPTT-SL), PTT-LA (aPTT-LA), ratio aPTT-LA/aPTT-SL (aPTT-ratio), and Russell's viper venom (RVV) based LA-Check. LA positive samples were identified by mixing studies and diluted RVV confirmation test (LA-Check/LA-Sure). Results: Pilot study: All screening strategies had a 100% sensitivity, and the aPTT-ratio reached the highest specificity (82%; 95%CI: 74-90%). Within the evaluation study, following sensitivities for LA screening were observed: aPTT-SL 59.0% (95%CI: 57-61%), aPTT-LA 82.1% (95%CI: 80-84%), aPTT-ratio 92.3% (95%CI: 91-94), and LA-Check 83.3% (95%CI: 82-85%). Conclusion: Calculating a ratio between the LA-sensitive PTT-LA and the less sensitive Pathromtin-SL improves the performance of the PTT-LA itself and represents a simple and sensitive aPTT-based integrated strategy for LA screening.
Resumo:
Repeated Chlamydia trachomatis infections after treatment are common. One reason is reinfection from untreated partners in ongoing sexual partnerships. Mathematical models that are used to predict the impact of screening on reducing chlamydia prevalence often do not incorporate reinfection and might overestimate the expected impact. We describe a pair compartmental model that explicitly incorporates sexual partnership duration and reinfection. The pair model predicts a weaker impact of screening when compared directly with a model that does not accommodate partnerships. Effective management of sex partners to prevent reinfection might need to be strengthened in chlamydia control programs.
Resumo:
A long-term study over 25 months was conducted to evaluate the effects of genetically modified corn on performance of lactating dairy cows. Thirty-six dairy cows were assigned to two feeding groups and fed with diets based on whole-crop silage, kernels and whole-crop cobs from Bt-corn (Bt-MON810) or its isogenic not genetically modified counterpart (CON) as main components. The study included two consecutive lactations. There were no differences in the chemical composition and estimated net energy content of Bt-MON810 and CON corn components and diets. CON feed samples were negative for the presence of Cry1Ab protein, while in Bt-MON810 feed samples the Cry1Ab protein was detected. Cows fed Bt-MON810 corn had a daily Cry1Ab protein intake of 6.0 mg in the first lactation and 6.1 mg in the second lactation of the trial. Dry matter intake (DMI) was 18.8 and 20.7 kg/cow per day in the first and the second lactation of the trial, with no treatment differences. Similarly, milk yield (23.8 and 29.0 kg/cow per day in the first and the second lactation of the trial) was not affected by dietary treatment. There were no consistent effects of feeding MON810 or its isogenic CON on milk composition or body condition. Thus, the present long-term study demonstrated the compositional and nutritional equivalence of Bt-MON810 and its isogenic CON.
Resumo:
The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.
Resumo:
OBJECTIVE: To compare the effect of bimatoprost and the fixed combination of latanoprost and timolol (LTFC) on 24-hour mean intraocular pressure (IOP) after patients are switched from a nonfixed combination of latanoprost and timolol. DESIGN: Randomized, double-masked, multicenter clinical trial. PARTICIPANTS: Two hundred patients with glaucoma or ocular hypertension. METHODS: Included were patients who were controlled (IOP < 21 mmHg) on the nonfixed combination of latanoprost and timolol for at least 3 months before the baseline visit or patients on monotherapy with either latanoprost or timolol who were eligible for dual therapy not being fully controlled on monotherapy. The latter group of patients underwent a 6-week wash-in phase with the nonfixed combination of latanoprost and timolol before baseline IOP determination and study inclusion. Supine and sitting position IOPs were recorded at 8 pm, midnight, 5 am, 8 am, noon, and 4 pm at baseline, week 6, and week 12 visits. MAIN OUTCOME MEASURE: An analysis of covariance model was used for a noninferiority test of the primary efficacy variable, with mean area under the 24-hour IOP curve after 12 weeks of treatment as response variable and treatment, center, and baseline IOP as factors. A secondary analysis was performed on the within-treatment change from baseline. RESULTS: Mean baseline IOPs were 16.3+/-3.3 mmHg and 15.5+/-2.9.mmHg in the bimatoprost and LTFC groups, respectively. At week 12, mean IOPs were 16.1+/-2.5 mmHg for the bimatoprost group and 16.3+/-3.7 mmHg for the LTFC group, and no significant difference between the 2 treatment groups could be found. As compared with baseline, mean IOP increased by 0.3+/-3.6 mmHg during the day and decreased by 0.8+/-3.8 mmHg during the night in the bimatoprost group, whereas there were increases of 1.43+/-2.6 mmHg and 0.14+/-3.2 mmHg in the LTFC group, respectively. CONCLUSIONS: Bimatoprost is not inferior to the LTFC in maintaining IOP at a controlled level during a 24-hour period in patients switched from the nonfixed combination of latanoprost and timolol.
Resumo:
PURPOSE: The clinical role of CAD systems to detect breast cancer, which have not been on cancer containing mammograms not detected by the radiologist was proven retrospectively. METHODS: All patients from 1992 to 2005 with a histologically verified malignant breast lesion and a mammogram at our department, were analyzed in retrospect focussing on the time of detection of the malignant lesion. All prior mammograms were analyzed by CAD (CADx, USA). The resulting CAD printout was matched with the cancer containing images yielding to the radiological diagnosis of breast cancer. CAD performance, sensitivity as well as the association of CAD and radiological features were analyzed. RESULTS: 278 mammograms fulfilled the inclusion criteria. 111 cases showed a retrospectively visible lesion (71 masses, 23 single microcalcification clusters, 16 masses with microcalcifications, in one case two microcalcification clusters). 54/87 masses and 34/41 microcalcifications were detected by CAD. Detection rates varied from 9/20 (ACR 1) to 5/7 (ACR 4) (45% vs. 71%). The detection of microcalcifications was not influenced by breast tissue density. CONCLUSION: CAD might be useful in an earlier detection of subtle breast cancer cases, which might remain otherwise undetected.
Resumo:
BACKGROUND: The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. METHODS: The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. RESULTS: The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. CONCLUSIONS: For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. CLINICAL IMPLICATIONS: When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
The aim of this study was to assess the influence of the zero value subtraction on the performance of laser fluorescence (LFpen) for approximal caries detection. Three areas (cuspal, middle and cervical) of both mesial and distal buccal surfaces of 78 permanent molars were assessed using both wedge-shaped (WDG) and tapered wedge-shaped (TWDG) tips. With the addition of the average, one cut-off value for each area was obtained and the performance was assessed. The areas under the receiver operating characteristics (ROC) curve, specificity, sensitivity and accuracy with and without the zero value subtraction were calculated. The McNemar test revealed a statistically significant difference for specificity at thresholds D(1), D(2) and D(3) (WDG) and D(1) and D(2) (TWDG) when the zero value subtraction was not performed. Influence of the zero value subtraction on the LFpen performance was observed for approximal caries detection. However, when modified cut-off values were used, the zero value subtraction could be eliminated.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.