46 resultados para The Sound and the Fury


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We introduce a justification logic with a novel constructor for evidence terms, according to which the new information itself serves as evidence for believing it. We provide a sound and complete axiomatization for belief expansion and minimal change and explain how the minimality can be graded according to the strength of reasoning. We also provide an evidential analog of the Ramsey axiom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate the bonding of simplified adhesive systems to sound and caries-affected dentin of primary teeth with microtensile (µTBS) and nanoleakage (NL) tests. MATERIALS AND METHODS Occlusal cavities were prepared in 36 sound second primary molars. Half of the specimens were submitted to pH cycling to simulate caries-affected dentin. Teeth were randomly restored with one of three materials: the etch-and-rinse adhesive system Adper Single Bond 2 (SB), the two-step self-etching adhesive system Adper SE Plus (SE), and the one-step self-etching adhesive system Adper Easy One (EASY). After storage for 24 h, specimens with cross-sectional areas of 0.8 mm2 were prepared for microtensile testing (1 mm/min). One stick from each tooth was immersed in silver nitrate solution (24 h) and allowed to develop for 8 h in order to score the nano leakage with SEM. The fracture pattern was evaluated using a stereomicroscope (400X). The µTBS means were analyzed by two-way ANOVA and Tukey's post-hoc test. For NL, the Kruskal- Wallis and Mann-Whitney tests were used (α < 0.05). RESULTS SB (35.5 ± 3.5) showed the highest µTBS value to sound dentin, followed by EASY (26.3 ± 1.9) and SE (18.2 ± 6.5) (p < 0.05). No difference among materials was observed for caries-affected dentin (SB: 17.8 ± 4.2; SE: 13.9 ± 3.2; EASY: 14.4 ± 4.2, p > 0.05). For all groups, adhesive/mixed fracture prevailed. Caries affected dentin promoted silver nitrate uptake into the adhesive interface; however, with SE, the nano leakage was more pronounced than in the other adhesive systems, even in sound dentin. CONCLUSION Caries-affected dentin negatively influences the bond strength and nano leakage of the two-step etch-and-rinse and one-step self-etching adhesive systems tested in primary teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Starting off from the usual language of modal logic for multi-agent systems dealing with the agents’ knowledge/belief and common knowledge/belief we define so-called epistemic Kripke structures for intu- itionistic (common) knowledge/belief. Then we introduce corresponding deductive systems and show that they are sound and complete with respect to these semantics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although there has been a significant decrease in caries prevalence in developed countries, the slower progression of dental caries requires methods capable of detecting and quantifying lesions at an early stage. The aim of this study was to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent 2095 laser fluorescence device [LF], DIAGNOdent 2190 pen [LFpen], and VistaProof fluorescence camera [FC]) in monitoring the progression of noncavitated caries-like lesions on smooth surfaces. Caries-like lesions were developed in 60 blocks of bovine enamel using a bacterial model of Streptococcus mutans and Lactobacillus acidophilus . Enamel blocks were evaluated by two independent examiners at baseline (phase I), after the first cariogenic challenge (eight days) (phase II), and after the second cariogenic challenge (a further eight days) (phase III) by two independent examiners using the LF, LFpen, and FC. Blocks were submitted to surface microhardness (SMH) and cross-sectional microhardness analyses. The intraclass correlation coefficient for intra- and interexaminer reproducibility ranged from 0.49 (FC) to 0.94 (LF/LFpen). SMH values decreased and fluorescence values increased significantly among the three phases. Higher values for sensitivity, specificity, and area under the receiver operating characteristic curve were observed for FC (phase II) and LFpen (phase III). A significant correlation was found between fluorescence values and SMH in all phases and integrated loss of surface hardness (ΔKHN) in phase III. In conclusion, fluorescence-based methods were effective in monitoring noncavitated caries-like lesions on smooth surfaces, with moderate correlation with SMH, allowing differentiation between sound and demineralized enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM This study aimed to evaluate the effect of a digital learning tool on undergraduate dental students' performance in detecting dental caries using ICDAS. METHODS An experimental digital learning tool (DLT) was created using digital photographs of sound and carious teeth. Thirty-nine students were divided into three groups (n = 13) and each assessed 12 randomly allocated patients before and after learning strategies: G1, ICDAS e-learning program; G2, ICDAS e-learning program plus DLT; G3, no learning strategy. Students (n = 32) reassessed patients 2 weeks after training. RESULTS Comparing before and after the learning strategies, any difference in the values of specificity and area under the ROC curve for all groups was found. Sensitivity was statistically significantly higher for G1 and G2. Comparing the groups, G2 showed a significant increase in sensitivity at the D2 and D3 thresholds. Spearman's correlations with the gold standard before and after the learning strategy were 0.60 and 0.61 for G1, 0.57 and 0.63 for G2, and 0.54 and 0.54 for G3, respectively. The Wilcoxon test showed a statistically significant difference between the values obtained before and after learning strategies for G1 and G2. CONCLUSIONS Use of the DLT after the ICDAS e-learning program tended to increase the sensitivity of ICDAS used by undergraduate dental students. The DLT appeared to improve dental students' ability to use ICDAS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study evaluates the long-term effects of a preschool training in phonological awareness and letter- sound correspondence.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Existing lower-limb, region-specific, patient-reported outcome measures have clinimetric limitations, including limitations in psychometric characteristics (eg, lack of internal consistency, lack of responsiveness, measurement error) and the lack of reported practical and general characteristics. A new patient-reported outcome measure, the Lower Limb Functional Index (LLFI), was developed to address these limitations. Objective The purpose of this study was to overcome recognized deficiencies in existing lower-limb, region-specific, patient-reported outcome measures through: (1) development of a new lower-extremity outcome scale (ie, the LLFI) and (2) evaluation of the clinimetric properties of the LLFI using the Lower Extremity Functional Scale (LEFS) as a criterion measure. Design This was a prospective observational study. Methods The LLFI was developed in a 3-stage process of: (1) item generation, (2) item reduction with an expert panel, and (3) pilot field testing (n=18) for reliability, responsiveness, and sample size requirements for a larger study. The main study used a convenience sample (n=127) from 10 physical therapy clinics. Participants completed the LLFI and LEFS every 2 weeks for 6 weeks and then every 4 weeks until discharge. Data were used to assess the psychometric, practical, and general characteristics of the LLFI and the LEFS. The characteristics also were evaluated for overall performance using the Measurement of Outcome Measures and Bot clinimetric assessment scales. Results The LLFI and LEFS demonstrated a single-factor structure, comparable reliability (intraclass correlation coefficient [2,1]=.97), scale width, and high criterion validity (Pearson r=.88, with 95% confidence interval [CI]). Clinimetric performance was higher for the LLFI compared with the LEFS on the Measurement of Outcome Measures scale (96% and 95%, respectively) and the Bot scale (100% and 83%, respectively). The LLFI, compared with the LEFS, had improved responsiveness (standardized response mean=1.75 and 1.64, respectively), minimal detectable change with 90% CI (6.6% and 8.1%, respectively), and internal consistency (α=.91 and .95, respectively), as well as readability with reduced user error and completion and scoring times. Limitations Limitations of the study were that only participants recruited from outpatient physical therapy clinics were included and that no specific conditions or diagnostic subgroups were investigated. Conclusion The LLFI demonstrated sound clinimetric properties. There was lower response error, efficient completion and scoring, and improved responsiveness and overall performance compared with the LEFS. The LLFI is suitable for assessment of lower-limb function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To present the safety profile, the early healing phase and the clinical outcomes at 24 weeks following treatment of human intrabony defects with open flap debridement (OFD) alone or with OFD and rhGDF-5 adsorbed onto a particulate β-tricalcium phosphate (β-TCP) carrier. Twenty chronic periodontitis patients, each with at least one tooth exhibiting a probing depth ≥6 mm and an associated intrabony defect ≥4 mm entered the study. Ten subjects (one defect/patient) were randomized to receive OFD alone (control) and ten subjects OFD combined with rhGDF-5/β-TCP. Blood samples were collected at screening, and at weeks 2 and 24 to evaluate routine hematology and clinical chemistry, rhGDF-5 plasma levels, and antirhGDF-5 antibody formation. Plaque and gingival indices, bleeding on probing, probing depth, clinical attachment level, and radiographs were recorded pre- and 24 weeks postsurgery. Comparable safety profiles were found in the two treatment groups. Neither antirhGDF-5 antibody formation nor relevant rhGDF-5 plasma levels were detected in any patient. At 6 months, treatment with OFD + rhGDF-5/β-TCP resulted in higher but statistically not significant PD reduction (3.7 ± 1.2 vs. 3.1 ± 1.8 mm; p = 0.26) and CAL gain (3.2 ± 1.7 vs. 1.7 ± 2.2 mm; p = 0.14) compared to OFD alone. In the tested concentration, the use of rhGDF-5/β-TCP appeared to be safe and the material possesses a sound biological rationale. Thus, further adequately powered, randomized controlled clinical trials are warranted to confirm the clinical relevance of this new approach in regenerative periodontal therapy. rhGDF-5/β-TCP may represent a promising new techology in regenerative periodontal therapy.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: The diagnosis of lameness caused by proximal metacarpal and metatarsal pain can be challenging. Magnetic resonance imaging (MRI) offers the possibility for further diagnosis but there have been no studies on the normal MRI appearance of the origin of the suspensory ligament (OSL) in conjunction with ultrasonography and histology. OBJECTIVES: To describe the MRI appearance of the OSL in fore- and hindlimbs of sound horses and compare it to the ultrasonographic and histological appearance. The findings can be used as reference values to recognise pathology in the OSL. METHODS: The OSL in the fore- and hindlimbs of 6 sound horses was examined by ultrasonography prior to death, and MRI and histology post mortem. Qualitative evaluation and morphometry of the OSL were performed and results of all modalities compared. RESULTS: Muscular tissue, artefacts, variable SL size and shape complicated ultrasonographic interpretation. In MRI and histology the forelimb OSL consisted of 2 portions, the lateral being significantly thicker than medial. The hindlimb SL had a single large area of origin. In fore- and hindlimbs, the amount of muscular tissue was significantly larger laterally than medially. Overall SL measurements using MRI were significantly higher than using histology and ultrasonography and histological higher than ultrasonographic measurements. Morphologically, there was a good correlation between MRI and histology. CONCLUSIONS: MRI provides more detailed information than ultrasonography regarding muscle fibre detection and OSL dimension and correlates morphologically well with histology. Therefore, ultrasonographic results should be regarded with caution. POTENTIAL RELEVANCE: MRI may be a diagnostic aid when other modalities fail to identify clearly the cause of proximal metacarpal and metatarsal pain; and may improve selection of adequate therapy and prognosis for injuries in this region.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Human subjects overestimate the change of rising intensity sounds compared with falling intensity sounds. Rising sound intensity has therefore been proposed to be an intrinsic warning cue. In order to test this hypothesis, we presented rising, falling, and constant intensity sounds to healthy humans and gathered psychophysiological and behavioral responses. Brain activity was measured using event-related functional magnetic resonance imaging. We found that rising compared with falling sound intensity facilitates autonomic orienting reflex and phasic alertness to auditory targets. Rising intensity sounds produced neural activity in the amygdala, which was accompanied by activity in intraparietal sulcus, superior temporal sulcus, and temporal plane. Our results indicate that rising sound intensity is an elementary warning cue eliciting adaptive responses by recruiting attentional and physiological resources. Regions involved in cross-modal integration were activated by rising sound intensity, while the right-hemisphere phasic alertness network could not be supported by this study.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.