21 resultados para TN
Resumo:
BACKGROUND: Diabetic patients with transmetatarsal amputation (TMA) for chronic forefoot ulceration or necrosis are at high risk for postoperative skin breakdown and subsequent amputation. Locally applied antibiotics may reduce the revision rate and improve the outcome. MATERIAL AND METHODS: In a retrospective comparative study, 60 diabetic patients (65 feet) with forefoot ulceration or necrosis were treated with TMA by three surgeons in three hospitals. In the "beads group'' (46 patients, 49 feet) TMA was combined with local application of bioabsorbable, tobramycin impregnated calcium sulphate beads (OsteoSet-T beads, Wright Medical, Memphis, TN) as a single-stage procedure. The remaining 16 patients had transmetatarsal amputation without beads at the surgeon's discretion and acted as a control group. For all patients, time to healing, length of hospital stay, number of revisions for wound breakdown and conversions to a higher-level amputation were retrospectively reviewed. Of the 60 patients 17 had died and three were lost to followup, leaving 40 patients available for latest followup at 29 months. The Foot ; Ankle Outcome Score, Foot Function index, SF-36, and Comorbidity score were recorded. RESULTS: The revision rate for wound breakdown after TMA was 8.2% (4/49) in the beads group, and 25% (4/16) in the control group (p<0.05). At latest followup, 27% (13/49) in the beads group, and 25% (4/16) in the control group had to be converted to transtibial amputation. Patients in the beads group scored worse for activities of daily living in the FAOS and SF-36 (p < 0.05), and demonstrated more health problems in the Comorbidity scores (not significant), indicating sicker individuals in the beads group. CONCLUSION: Bioabsorbable calcium sulphate antibiotic beads may be a useful addition for TMA for patients with non-healing diabetic ulcerations of the forefoot. The single-stage procedure could have a significant impact on the management of diabetic forefoot ulcerations by preventing additional hospital stays, improving the patient's quality of life and minimizing cost.
Resumo:
OBJECTIVE: Multiple studies have proved that microvascular decompression (MVD) is the treatment of choice in cases of medically refractory trigeminal neuralgia (TN). In the elderly, however, the surgical risks related to MVD are assumed to be unacceptably high and various alternative therapies have been proposed. We evaluated the outcomes of MVD in patients aged older than 65 years of age and compared them with the outcomes in a matched group of younger patients. The focus was on procedure-related morbidity rate and long-term outcome. METHODS: This was a retrospective study of 112 patients with TN operated on consecutively over 22 years. The main outcome measures were immediate and long-term postoperative pain relief and neurological status, especially function of trigeminal, facial, and cochlear nerves, as well as surgical complications. A questionnaire was used to assess long-term outcome: pain relief, duration of a pain-free period, need for pain medications, time to recurrence, pain severity, and need for additional treatment. RESULTS: The mean age was 70.35 years. The second and third branches of the trigeminal nerve were most frequently affected (37.3%). The mean follow-up period was 90 months (range, 48-295 months). Seventy-five percent of the patients were completely pain free, 11% were never pain free, and 14% experienced recurrences. No statistically significant differences existed in the outcome between the younger and older patient groups. Postoperative morbidity included trigeminal hypesthesia in 6.25%, hypacusis in 5.4%, and complete hearing loss, vertigo, and partial facial nerve palsy in 0.89% each. Cerebrospinal fluid leak and meningitis occurred in 1 patient each. There were no mortalities in both groups. CONCLUSION: MVD for TN is a safe procedure even in the elderly. The risk of serious morbidity or mortality is similar to that in younger patients. Furthermore, no significant differences in short- and long-term outcome were found. Thus, MVD is the treatment of choice in patients with medically refractory TN, unless their general condition prohibits it.
Resumo:
Varved lake sediments are excellent natural archives providing quantitative insights into climatic and environmental changes at very high resolution and chronological accuracy. However, due to the multitude of responses within lake ecosystems it is often difficult to understand how climate variability interacts with other environmental pressures such as eutrophication, and to attribute observed changes to specific causes. This is particularly challenging during the past 100 years when multiple strong trends are superposed. Here we present a high-resolution multi-proxy record of sedimentary pigments and other biogeochemical data from the varved sediments of Lake Żabińskie (Masurian Lake District, north-eastern Poland, 54°N–22°E, 120 m a.s.l.) spanning AD 1907 to 2008. Lake Żabińskie exhibits biogeochemical varves with highly organic late summer and winter layers separated by white layers of endogenous calcite precipitated in early summer. The aim of our study is to investigate whether climate-driven changes and anthropogenic changes can be separated in a multi-proxy sediment data set, and to explore which sediment proxies are potentially suitable for long quantitative climate reconstructions. We also test if convoluted analytical techniques (e.g. HPLC) can be substituted by rapid scanning techniques (visible reflectance spectroscopy VIS-RS; 380–730 nm). We used principal component analysis and cluster analysis to show that the recent eutrophication of Lake Żabińskie can be discriminated from climate-driven changes for the period AD 1907–2008. The eutrophication signal (PC1 = 46.4%; TOC, TN, TS, Phe-b, high TC/CD ratios total carotenoids/chlorophyll-a derivatives) is mainly expressed as increasing aquatic primary production, increasing hypolimnetic anoxia and a change in the algal community from green algae to blue-green algae. The proxies diagnostic for eutrophication show a smooth positive trend between 1907 and ca 1980 followed by a very rapid increase from ca. 1980 ± 2 onwards. We demonstrate that PC2 (24.4%, Chl-a-related pigments) is not affected by the eutrophication signal, but instead is sensitive to spring (MAM) temperature (r = 0.63, pcorr < 0.05, RMSEP = 0.56 °C; 5-yr filtered). Limnological monitoring data (2011–2013) support this finding. We also demonstrate that scanning visible reflectance spectroscopy (VIS-RS) data can be calibrated to HPLC-measured chloropigment data and be used to infer concentrations of sedimentary Chl-a derivatives {pheophytin a + pyropheophytin a}. This offers the possibility for very high-resolution (multi)millennial-long paleoenvironmental reconstructions.
Resumo:
Einleitung und Ziel: Das Arbeiten mit Adhäsivsystemen und Kompositmaterialien ist techniksensitiv und oft auch zeitaufwändig. Adhäsivsysteme und Kompositmaterialien sind feuchtigkeitsanfällig, weswegen die Verwendung eines Kofferdams von den Herstellern empfohlen wird - nicht nur, um während des Arbeitens mit Adhäsivsystemen und Kompositmaterialien die Gefahr einer Blut- oder Speichelkontamination zu minimieren sondern auch, um die hohe relative Luftfeuchtigkeit in der Mundhöhle auf die Luftfeuchtigkeit der Umgebung zu reduzieren. Abgesehen davon bestehen viele Adhäsivsysteme aus mehreren Applikationsschritten und diese Applikationsschritte weisen jeweils von den Herstellern genau angegebene Applikationszeiten auf. Je nach Adhäsivsystem erscheinen diese Applikationszeiten relativ lang und im klinischen Alltag kann die Gefahr bestehen, dass es zu einer Reduktion der vom Hersteller angegeben Applikationszeiten kommt. Es ist sehr wahrscheinlich, dass sowohl erhöhte relative Luftfeuchtigkeit als auch reduzierte Applikationszeiten die Dentinhaftkraft von Adhäsivsystemen negativ beeinflussen. Das Ziel dieser Studie war folglich, den Einfluss von relativer Luftfeuchtigkeit und Applikationszeit auf die Dentinhaftkraft von sechs verschiedenen Adhäsivsystemen zu untersuchen. Material und Methoden: Insgesamt 360 extrahierte menschliche Molaren ohne Füllungen und/oder Karies wurden verwendet (n=15 pro Gruppe; 24 Gruppen). Die Molaren wurden gereinigt und von okklusal bis ins mittlere Zahnkronendentin plangeschliffen. Die plangeschliffenen Molaren wurden anschliessend in selbsthärtendem Kunststoff eingebettet. Danach wurden die Oberflächen des Zahnkronendentins mit einem von sechs Adhäsivsystemen behandelt und Komposit (Filtek Z250; 3M ESPE) in Form eines Zylinders appliziert. Die sechs Adhäsivsysteme umfassten: 1) Syntac Classic (Ivoclar Vivadent), 2) OptiBond FL (Kerr), 3) Clearfil SE Bond (Kuraray), 4) AdheSE (Ivoclar Vivadent), 5) Xeno Select (DENTSPLY DeTrey) sowie 6) Scotchbond Universal (3M ESPE). Die Applikation des Adhäsivsystems und des Kompositzylinders wurde unter vier experimentellen Bedingungen durchgeführt. Die vier experimentellen Bedingungen wurden in einer modifizierten Handschuhbox erstellt (Abb. 1; CSL-GB24, Cleaver Scientific, Rugby, Grossbritannien) und umfassten: a) relative Luftfeuchtigkeit der Umgebung (~45%) und Applikationszeit gemäss Herstellerangaben, b) relative Luftfeuchtigkeit der Umgebung (~45%) und reduzierte Applikationszeit, c) erhöhte relative Luftfeuchtigkeit (≥85%) und Applikationszeit gemäss Herstellerangaben sowie d) erhöhte relative Luftfeuchtigkeit (≥85%) und reduzierte Applikationszeit. Nach 24 Stunden Lagerung wurden die auf Dentin applizierten Kompositzylinder in einer Universalprüfmaschine (Abb. 2; zwicki Z1.0 TN, Zwick, Ulm, Deutschland) mittels Scherkrafttest belastet (Traversengeschwindigkeit: 1 mm/min) und so die Haftkraftwerte bestimmt. Die Haftkraftwerte wurden anschliessend mit einer nichtparametrischen Varianzanalyse statistisch analysiert, gefolgt von Kruskal-Wallis- und Mann Whitney U-Tests sowie einer Bonferroni-Holm Korrektur für multiples Testen. Das Signifikanzniveau wurde auf α = 0.05 festgelegt. Resultate: Erhöhte relative Luftfeuchtigkeit sowie reduzierte Applikationszeit hatten keinen signifikanten Einfluss auf die Haftkraft von zwei der sechs untersuchten Adhäsivsysteme (Clearfil SE Bond und Scotchbond Universal; p = 1.00). Die Haftkraft der anderen vier Adhäsivsysteme (Syntac Classic, OptiBond FL, AdheSE und Xeno Select) wurde durch eine reduzierte Applikationszeit nicht signifikant beeinflusst (p ≥ 0.403). Allerdings reduzierte eine erhöhte relative Luftfeuchtigkeit (ungeachtet der Applikationszeit) die Haftkraft von Syntac Classic, OptiBond FL und Xeno Select signifikant (p ≤ 0.003). Eine erhöhte relative Luftfeuchtigkeit reduzierte die Haftkraft von AdheSE nur dann signifikant, wenn das Adhäsivsystem mit Applikationszeit gemäss Herstellerangaben verwendet wurde (p = 0.002). Hinsichtlich Unterschiede in der Haftkraft zwischen den sechs Adhäsivsystemen zeigte sich, dass OptiBond FL und Scotchbond Universal generell (sprich ungeachtet der vier experimentellen Bedingungen) die höchste Haftkraft erzielten. Von den anderen vier Adhäsivsystemen wurde Clearfil SE Bond am wenigsten durch erhöhte relative Luftfeuchtigkeit oder reduzierte Applikationszeit beeinflusst und zeigte zwar niedrigere Haftkraftwerte im Vergleich zu OptiBond FL und Scotchbond Universal dafür aber die konstanteste Haftkraft unter allen vier experimentellen Bedingungen. Schlussfolgerung: Die Dentinhaftkraft von zwei der sechs untersuchten Adhäsivsysteme (Clearfil SE Bond und Scotchbond Universal) wurde weder durch erhöhte relative Luftfeuchtigkeit noch durch reduzierte Applikationszeiten beeinflusst. Die Haftkraft der anderen vier Adhäsivsysteme wurde vor allem durch eine erhöhte relative Luftfeuchtigkeit negativ beeinflusst, grossmehrheitlich aber nicht durch eine reduzierte Applikationszeit. Klinisch ist daher die Kontrolle und Reduktion der relativen Luftfeuchtigkeit durch die Verwendung eines Kofferdams sehr zu empfehlen. Obwohl diese Studie gezeigt hat, dass reduzierte Applikationszeiten einen weniger starken, negativen Einfluss auf die Haftkraft haben, ist es trotzdem angezeigt, die Gebrauchsanleitungen der Adhäsivsysteme zu befolgen und sich an die Herstellerangaben zu halten.