58 resultados para TIPS-pentacene
Resumo:
Connective tissue growth factor (CTGF) is a profibrotic protein whose systemic levels are increased in liver cirrhosis. Here, association of CTGF with stages of liver injury and complications of cirrhotic liver disease has been analyzed in patients with different aetiologies of hepatic injury. CTGF is significantly increased in portal venous serum (PVS), hepatic venous serum (HVS) and systemic venous serum (SVS) of 46 patients with liver cirrhosis compared to eight liver-healthy controls. In patients´ blood samples CTGF in HVS is about 6% higher than PVS levels indicating that CTGF produced in the liver is released to the circulation. CTGF is not associated with stages of liver cirrhosis defined by CHILD-PUGH or MELD score nor with secondary complications of portal hypertension (varices, ascites, spontaneous bacterial peritonitis). Transforming growth factor β (TGFβ) induces CTGF synthesis in hepatocytes and a positive association of systemic TGFβ1 and SVS and HVS CTGF is found. Three months after placing transjugular intrahepatic portosystemic shunt (TIPS) hepatic venous pressure gradient is reduced whereas CHILD-PUGH score, TGFβ1 and CTGF are not altered in serum of 15 patients. Current data show that the cirrhotic liver releases little CTGF but SVS, HVS and PVS CTGF levels are not associated with residual liver function and complications of cirrhosis.
Resumo:
The mammalian kidney develops from the ureteric bud and the metanephric mesenchyme. In mice, the ureteric bud invades the metanephric mesenchyme at day E10.5 and begins to branch. The tips of the ureteric bud induce the metanephric mesenchyme to condense and form the cap mesenchyme. Some cells of this cap mesenchyme undergo a mesenchymal-to-epithelial transition and differentiate into renal vesicles, which further develop into nephrons. The developing kidney expresses Fibroblast growth factor (Fgf)1, 7, 8, 9, 10, 12 and 20 and Fgf receptors Fgfr1 and Fgfr2. Fgf7 and Fgf10, mainly secreted by the metanephric mesenchyme, bind to Fgfr2b of the ureteric bud and induce branching. Fgfr1 and Fgfr2c are required for formation of the metanephric mesenchyme, however the two receptors can substitute for one another. Fgf8, secreted by renal vesicles, binds to Fgfr1 and supports survival of cells in the nascent nephrons. Fgf9 and Fgf20, expressed in the metanephric mesenchyme, are necessary to maintain survival of progenitor cells in the cortical region of the kidney. FgfrL1 is a novel member of the Fgfr family that lacks the intracellular tyrosine kinase domain. It is expressed in the ureteric bud and all nephrogenic structures. Targeted deletion of FgfrL1 leads to severe kidney dysgenesis due to the lack of renal vesicles. FgfrL1 is known to interact mainly with Fgf8. It is therefore conceivable that FgfrL1 restricts signaling of Fgf8 to the precise location of the nascent nephrons. It might also promote tight adhesion of cells in the condensed metanephric mesenchyme as required for the mesenchymal-to-epithelial transition.
Resumo:
BACKGROUND: Ilioinguinal and iliohypogastric nerve blocks may be used in the diagnosis of chronic groin pain or for analgesia for hernia repair. This study describes a new ultrasound-guided approach to these nerves and determines its accuracy using anatomical dissection control. METHODS: After having tested the new method in a pilot cadaver, 10 additional embalmed cadavers were used to perform 37 ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve. After injection of 0.1 ml of dye the cadavers were dissected to evaluate needle position and colouring of the nerves. RESULTS: Thirty-three of the thirty-seven needle tips were located at the exact target point, in or directly at the ilioinguinal or iliohypogastric nerve. In all these cases the targeted nerve was coloured entirely. In two of the remaining four cases parts of the nerves were coloured. This corresponds to a simulated block success rate of 95%. In contrast to the standard 'blind' techniques of inguinal nerve blocks we visualized and targeted the nerves 5 cm cranial and posterior to the anterior superior iliac spine. The median diameters of the nerves measured by ultrasound were: ilioinguinal 3.0x1.6 mm, and iliohypogastric 2.9x1.6 mm. The median distance of the ilioinguinal nerve to the iliac bone was 6.0 mm and the distance between the two nerves was 10.4 mm. CONCLUSIONS: The anatomical dissections confirmed that our new ultrasound-guided approach to the ilioinguinal and iliohypogastric nerve is accurate. Ultrasound could become an attractive alternative to the 'blind' standard techniques of ilioinguinal and iliohypogastric nerve block in pain medicine and anaesthetic practice.
Resumo:
Cryoultramicrotomy allows the sectioning of vitrified biological samples. These biological samples are preserved at the atomic level and represent the real structure at the moment of freezing. Cryoultramicrotomy produces ultra-thin cryosections that are investigated in a cryoelectron microscope. The necessity of working during the whole preparation at temperatures less than −140°C results in some difficulties, including the cryosection transfer from the knife-edge to the electron microscropy grid; the grid handling in the cryochamber and the grid transfer into the cryoholder of the electron microscope. Furthermore, ice crystal contamination (from air humidity) can obscure the structures of interest in the sections. It is mainly know-how and experience that will prevent the contamination of ice crystals and the recrystallization of the sections during the manipulations. Here, we describe the tips, tricks, the tools, and methods that help to overcome these burdens and pave the path for successful cryoultramicrotomy.
Resumo:
The laser device DIAGNOdent developed for the detection of occlusal caries has limited value on approximal surfaces. The aim of this study was to develop and to test a new laser fluorescence (LF) device for the detection of approximal caries. Light with a wavelength of 655 nm was transported to the approximal surface using two different sapphire fibre tips. Seventy-five teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured, they were defrosted, cleaned and calculus was removed with a scaler. The molars were set in blocks simulating the contact area of adults. Bitewing radiographs were obtained using Kodak Insight films. After two independent assessments with the new LF device, the teeth were histologically prepared, and assessed for caries extension. Using the laser, specificity values for D1 threshold (outer half of enamel), D2 threshold (inner half of enamel), D3 threshold (dentine) ranged between 0.81 and 0.93, sensitivity between 0.84 and 0.92 with no difference between the two tips. Bitewing radiography showed an inferior performance compared to LF (p<0.05). Intraex aminer reproducibility was high (kappa>.74). The new LF system might be a useful additional tool in detecting approximal caries. Because of its good reproducibility, it could be used to monitor caries regression or progression on approximal surfaces.
Resumo:
The new device DIAGNOdent pen based on red laser light induced fluorescence was introduced for the detection of approximal and occlusal caries. The aim of this study was to test its performance on occlusal surfaces. The new device comes with two different sapphire fibre tips: a cylindrical tip and a conical tip. The two new sapphire fibre tips were used and compared with the tip currently available with DIAGNOdent (DD). METHODS: The teeth were selected from a pool of extracted permanent human molars, which were stored frozen at -20 degrees C, until use. Prior to being measured the teeth were defrosted and cleaned. One hundred and nineteen teeth were selected and measured with the old tip and with the two new tips of the new device by two independent assessments. The teeth were histologically prepared and assessed for caries extension. RESULTS: Specificity values for D(1), D(2) and D(3) ranged between 0.69 and 0.89, sensitivity between 0.78 and 0.96. There were no statistically significant differences obtained between the two tips of the new and the one tip of the old device (p>0.05). Intra-examiner reliability with kappa values of >0.83 was high. CONCLUSIONS: In this study, the new laser fluorescence device performed on occlusal surfaces as well as the available device.
Resumo:
A variety of chronic kidney diseases tend to progress towards end-stage kidney disease. Progression is largely due to factors unrelated to the initial disease, including systemic hypertension and proteinuria. Drugs that block the renin-angiotensin II-aldosterone system, either ACE inhibitors or angiotensin II receptor antagonists, reduce both BP and proteinuria and appear superior to a more conventional antihypertensive treatment regimen in preventing progression to end-stage kidney disease. The most recent recommendations state that the BP goal in children with chronic kidney disease is the corresponding 90th centile for body height, age, and gender.Since satisfactory BP control is often not achieved, the mnemonic acronym DELTAREPROSI was generated to recall the following tips for the practical management of hypertension and proteinuria in childhood chronic renal parenchymal disease: DEfinition of hypertension and Low blood pressure TArget in REnal disease (90th centile calculated by means of simple formulas), potential of drugs inhibiting the REnin-angiotensin II-aldosterone system in hypertension and PROteinuria, advantages of SImplified treatment regimens and escalating the doses every SIx weeks.
Resumo:
PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.
Resumo:
PURPOSE: To retrospectively evaluate the midterm patency rate of the nitinol (Viatorr, W.L. Gore and Associates, Flagstaff, Ariz) stent-graft for direct intrahepatic portacaval shunt (DIPS) creation. MATERIALS AND METHODS: Institutional Review Board approval for this retrospective HIPAA-compliant study was obtained with waiver of informed consent. DIPS was created in 18 men and one woman (median age, 54 years; range, 45-65 years) by using nitinol polytetrafluoroethylene (PTFE)-covered stent-grafts. The primary indications were intractable ascites (n = 14), acute variceal bleeding (n = 3), and hydrothorax (n = 2). Follow-up included Doppler ultrasonography at 1, 6, and 12 months and venography with manometry at 6-month intervals after the procedure. Shunt patency and cumulative survival were evaluated by using the Kaplan-Meier method and survival curves were plotted. Differences in mean portosystemic gradients (PSGs) were evaluated by using the Student t test. Multiple regression analysis for survival and DIPS patency were performed for the following parameters: Child-Pugh class, model of end-stage liver disease score, pre- and post-DIPS PSGs, pre-DIPS liver function tests, and pre-DIPS creatinine levels. RESULTS: DIPS creation was successful in all patients. Effective portal decompression and free antegrade shunt flow was achieved in all patients. Intraperitoneal bleeding occurred in one patient during the procedure and was controlled during the same procedure by placing a second nitinol stent-graft. The primary patency rate was 100% at all times during the follow-up period (range, 2 days to 30 months; mean, 256 days; median, 160 days). Flow restrictors were deployed in two (11%) of 19 patients. The 1-year mortality rate was 37% (seven of 19). CONCLUSION: Patency after DIPS creation with the nitinol PTFE-covered stent-graft was superior to that after TIPS with the nitinol stent-graft.
Resumo:
The aim of this study was to assess the influence of the zero value subtraction on the performance of laser fluorescence (LFpen) for approximal caries detection. Three areas (cuspal, middle and cervical) of both mesial and distal buccal surfaces of 78 permanent molars were assessed using both wedge-shaped (WDG) and tapered wedge-shaped (TWDG) tips. With the addition of the average, one cut-off value for each area was obtained and the performance was assessed. The areas under the receiver operating characteristics (ROC) curve, specificity, sensitivity and accuracy with and without the zero value subtraction were calculated. The McNemar test revealed a statistically significant difference for specificity at thresholds D(1), D(2) and D(3) (WDG) and D(1) and D(2) (TWDG) when the zero value subtraction was not performed. Influence of the zero value subtraction on the LFpen performance was observed for approximal caries detection. However, when modified cut-off values were used, the zero value subtraction could be eliminated.
Resumo:
A reproducible, standardized and simple sample preparation methodology is the key to successful two-dimensional gel electrophoresis (2-DE). This chapter describes step-by-step the sample preparation of culture medium from Madin-Darby canine kidney (MDCK) cells. Tips and tricks are given to circumvent possible pitfalls.
Resumo:
STUDY DESIGN: Case report and review of the literature. OBJECTIVE: We describe the first case of a synovial cyst arising from pseudarthrosis of a previous dens fracture. The literature is reviewed and etiological, diagnostic, and therapeutic options of atlantoaxial cysts are discussed. SUMMARY OF BACKGROUND DATA: Symptomatic synovial cysts of the atlantoaxial joint are rare. To the authors' knowledge only 24 cases have been reported.A 60-year-old patient presented with bilateral hand numbness, quadrihyperreflexia, and gait deterioration. Magnetic resonance imaging of the cervical spine disclosed a cystic mass located at the transverse ligament of dens axis causing bulbomedullary compression. METHODS: Surgery was performed via transoral image guided approach. The ventral atlas arch, dens, transverse ligament, tectorial membrane, and the compressing cyst were removed, followed by a C0-C3 fusion. RESULTS: Two months postsurgery the patient recovered completely from the cervical myelopathy with transient remnant dysparesthesia of the finger tips. CONCLUSION: Magnetic resonance imaging findings are not specific enough to establish a preoperative diagnosis. Radical resection via image-guided transoral route followed by posterior fusion allows complete resection of the cystic lesion and results in excellent long-term decompression.
Resumo:
The exposure of the preparation margin and the control of the hemorrhage in the gingival sulcus are prerequisites for precise impressions and thereby improving the quality of indirectly fabricated restorations. The purpose of this review article is to summarize available evidence with respect to current methods of gingival retraction and to provide the clinician with practical tips.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
This article describes the structure and utilization of a computerized databank system for WHO mortality data. This system makes available "at finger-tips" data which previously were published by WHO in its blue volumes. The data can be handled much more flexible. At the moment the system provides information on age-standardized rates (direct standardization), total number of cases, as well as cover per age-group and year for about a hundred countries. The time period covered is 1950-1985, with exceptions for data which are not available to WHO.