186 resultados para Swan Ganz catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A first case of coronary stent implantation through a 4 French diagnostic catheter is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of maximum urethral closure pressure (MUCP) are a part of urodynamic investigations preceding an incontinence surgery and a part of urethral function tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilio-femoral deep vein thrombosis (DVT) has a high rate of long-term morbidity in the form of the postthrombotic syndrome (PTS). Therefore, management of acute thrombosis should not only focus on the prevention of acute complications such as propagation or embolisation of the initial clot but also on preventing PTS and recurrent thrombosis. Contemporary catheter-based treatments of deep vein thrombosis have proven to be safe and effective in selected patients. Current guidelines recommend medical therapy with anticoagulation alone for all but the most severe, limb-threatening thrombosis. They additionally allow for consideration of catheter-based treatment in patients with acute DVT and low risk of bleeding complications to prevent PTS. Recent studies favoring interventional therapy have not been included in these guidelines. Data on long-term outcome is expected to be published soon, clarifying and very likely strengthening the role of catheter-based treatments in the management of acute ilio-femoral DVT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The tradition of yearly reports on cardiac catheter interventions in Europe has been initiated in 1992. This 11th report presents aggregated data on cardiac catheter procedures in 30 European countries in the year 2002. DESIGN AND SETTING: A detailed questionnaire addressing summary data of all cardiac interventions was mailed to presidents or delegates of the national societies of cardiology in Europe. The questionnaire was distributed to all institutions with cardiac catheterisation programs. All questionnaires were compiled in a national summary data sheet, then entered into a central database and subsequently analysed. MAIN OUTCOME MEASURES: Coronary angiography, PTCA, and stenting in absolute numbers and per million inhabitants in the participating countries and the whole of Europe. RESULTS: Overall, 1,901,932 coronary angiograms were reported. The population-adjusted rate of coronary angiograms amounted to an absolute mean of 3358 per 10(6) inhabitants, an increase of 7% compared with 2001. A total of 686,869 PTCA procedures were reported. The mean European number of PTCAs per 10(6) inhabitants increased by 10% from 1103 in 2001 to 1213 in 2002. Procedures with stenting increased by 17% from 508,999 to 593,906. The stenting rate was 86% compared with 82% in 2001. CONCLUSIONS: In pace with epidemiological demand and the need to catch-up from underuse in certain countries, a continuous and considerable growth of coronary interventions can be observed. It will take years to find out whether the announced change of paradigm in the treatment of multivessel disease in the wake of drug-eluting stents will come true.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central venous catheters are established as vascular access in hemodialysis therapy. Vascular catheter misdirection may occur and is a well known problem. We present a rare catheter malposition in a young dialysis patient with consequent dilatation of the azygos vein system, simulating the appearance of an azygos continuation syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early catheter-related infection is a serious complication in cancer treatment, although risk factors for its occurrence are not well established. The authors conducted a prospective study to identify the risk factors for developing early catheter-related infection. METHODS: All consecutive patients with cancer who underwent insertion of a central venous catheter were enrolled and were followed prospectively during 1 month. The study endpoint was occurrence of early catheter-related infection. RESULTS: Over 10,392 catheter-days of follow-up, 14 of 371 patients had early catheter-related infections (14 patients in 10,392 catheter-days or 1.34 per 1000 catheter-days). The causative pathogens were gram positive in 11 of 14 patients. In univariate analysis, the risk factors for early catheter-related infection were aged <10 years (P = .0001), difficulties during insertion (P < 10(-6)), blood product administration (P < 10(-3)), parenteral nutrition (P < 10(-4)), and use >2 days (P < 10(-6)). In multivariate analysis, 3 variables remained significantly associated with the risk of early catheter-related infection: age <10 years (odds ratio [OR], 18.4; 95% confidence interval [95% CI], 1.9-106.7), difficulties during insertion procedure (OR, 25.6; 95% CI, 4.2-106), and parenteral nutrition (OR, 28.5; 95% CI, 4.2-200). CONCLUSIONS: On the day of insertion, 2 variables were identified that were associated with a high risk of developing an early catheter-related infection: young age and difficulties during insertion. The results from this study may be used to identify patients who are at high risk of infection who may be candidates for preventive strategies.