315 resultados para Surgical Instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obturator anterior hip dislocation is very rare. Poor results are described in patients with additional large transchondral fractures and treatment of these injuries remains challenging. Appropriate treatment recommendations are missing in the literature. This case report introduces surgical hip dislocation for osteochondral autograft transplantation with graft harvest from the nonweightbearing area of the head-neck junction as a salvage procedure in a large femoral head defect. We report the treatment and outcome of a 48-year-old man who sustained an anterior dislocation of the left hip after a motorcycle accident. After initial closed reduction in the emergency room, imaging analysis revealed a large osteochondral defect of the femoral head within the weightbearing area (10 × 20 mm, depth: 5 mm). The hip was exposed with a surgical hip dislocation using a trochanteric osteotomy. An osteochondral autograft was harvested from a nonweightbearing area of the femoral head and transferred into the defect. The patient was prospectively examined clinically and radiologically. Two years postoperatively, the patient was free of pain and complaints. The function of the injured hip was comparable to that of the contralateral, healthy hip and showed satisfying radiologic results. Surgical hip dislocation with a trochanteric flip osteotomy is a simple, one-step technique that allows full inspection of the hip to treat osteochondral femoral defects by osteochondral transplantation. The presented technique, used as a salvage procedure in a large femoral head defect, yielded good clinical and satisfying radiologic outcomes at the midterm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Acetabular fractures still are among the most challenging fractures to treat because of complex anatomy, involved surgical access to fracture sites and the relatively low incidence of these lesions. Proper evaluation and surgical planning is necessary to achieve anatomic reduction of the articular surface and stable fixation of the pelvic ring. The goal of this study was to test the feasibility of preoperative surgical planning in acetabular fractures using a new prototype planning tool based on an interactive virtual reality-style environment. Methods 7 patients (5 male and 2 female; median age 53 y (25 to 92 y)) with an acetabular fracture were prospectively included. Exclusion criterions were simple wall fractures, cases with anticipated surgical dislocation of the femoral head for joint debridement and accurate fracture reduction. According to the Letournel classification 4 cases had two column fractures, 2 cases had anterior column fractures and 1 case had a T-shaped fracture including a posterior wall fracture. The workflow included following steps: (1) Formation of a patient-specific bone model from preoperative computed tomography scans, (2) interactive virtual fracture reduction with visuo-haptic feedback, (3) virtual fracture fixation using common osteosynthesis implants and (4) measurement of implant position relative to landmarks. The surgeon manually contoured osteosynthesis plates preoperatively according to the virtually defined deformation. Screenshots including all measurements for the OR were available. The tool was validated comparing the preoperative planning and postoperative results by 3D-superimposition. Results Preoperative planning was feasible in all cases. In 6 of 7 cases superimposition of preoperative planning and postoperative follow-up CT showed a good to excellent correlation. In one case part of the procedure had to be changed due to impossibility of fracture reduction from an ilioinguinal approach. In 3 cases with osteopenic bone patient-specific prebent fixation plates were helpful in guiding fracture reduction. Additionally, anatomical landmark based measurements were helpful for intraoperative navigation. Conclusion The presented prototype planning tool for pelvic surgery was successfully integrated in a clinical workflow to improve patient-specific preoperative planning, giving visual and haptic information about the injury and allowing a patient-specific adaptation of osteosynthesis implants to the virtually reduced pelvis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the relationship between nationality, gender and age and use of health services among patients visiting an urban university hospital emergency department (ED).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burnout is a pathologic reaction in response to long-term work-related stress. The aim of this study was 2-fold: first, to assess the prevalence and degree of burnout among surgical residents and surgeons in Switzerland and, second, to identify predictors of burnout in the surgical community. Four hundred five of 618 anonymous questionnaires (65.5%) were returned. Among respondents, 3.7% and 35.1% showed high and moderate degrees of burnout, respectively. Respondents with high and moderate degrees of burnout had higher summary scores of perceived stress (P < .001). In multiple logistic regression analysis, the strongest predictors of burnout were poor interaction with nurses, disturbances due to telephone consultations, and high overall workload. To reduce burnout, new work models should be sought, in addition to decreasing work intensity and workload rather than restricting work hours alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 50-hour workweek limitation for surgical residents in Switzerland has a major effect on surgical training, resident quality of life, and patient care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no standard treatment for patients with locally advanced esophageal carcinoma without systemic metastasis in whom surgery is no longer considered a reasonable option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To compare changes in the largest cross-sectional area (CSA) of the median nerve in wrists undergoing surgical decompression with changes in wrists undergoing non-surgical treatment of carpal tunnel syndrome (CTS). Methods This study was a prospective cohort study in 55 consecutive patients with 78 wrists with established CTS, including 60 wrists treated with surgical decompression and 18 wrists with non-surgical treatment. A sonographic examination was scheduled before and 4 months after initiation of treatment. We compared changes in CSA of the median nerve between wrists with surgical treatment and wrists with non-surgical treatment using linear regression models. Results Decreases in CSA of the median nerve were more pronounced in wrists with CTS release than in wrists undergoing nonsurgical treatment (difference in means, 1.0 mm2; 95% confidence interval, 0.3–1.8 mm2). Results were robust to the adjustment for age, gender, and neurological severity at baseline. Among wrists with CTS release, those with postoperative CSA of 10 mm2 or less tended to have better clinical outcomes than those with postoperative CSA of greater than 10 mm2 (p=.055). Postoperative sonographic workup in the 3 patients with unfavorable outcome or recurrence identified likely causes for treatment failure in 2 patients. Conclusions In this observational study, surgical decompression was associated with a greater decrease in median nerve CSA than was nonsurgical treatment. Smaller postoperative CSAs may be associated with better clinical outcomes. Additional randomized trials are necessary to determine the optimal treatment strategy in different subgroups of patients with CTS. Type of study/level of evidence Therapeutic III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.