43 resultados para Subtopic retrieval


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSES: To evaluate the safety of inferior vena cava (IVC) filter retrieval in therapeutically anticoagulated patients in comparison to prophylactically or not therapeutically anticoagulated patients with respect to retrieval-related hemorrhagic complications. MATERIALS AND METHODS: This was a retrospective study of 115 consecutive attempted IVC filter retrievals in 110 patients. Filter retrievals were stratified as performed in patients who were therapeutically anticoagulated (group 1), prophylactically anticoagulated (group 2), or not therapeutically anticoagulated (group 3). The collected data included anticoagulant and antiplatelet medications (type, form and duration of administration, dosage) at the time of retrieval. Phone interviews and chart review was performed for the international normalized ratio (INR), activated partial thromboplastin time, platelet count, infusion of blood products, and retrieval-related hemorrhagic complications. RESULTS: Group 1 included 65 attempted filter retrievals in 61 therapeutically anticoagulated patients by measured INR or dosing when receiving low-molecular-weight heparin (LMWH). Four retrievals were not successful. In patients receiving oral anticoagulation, the median INR was 2.35 (range, 2 to 8). Group 2 comprised 23 successful filter retrievals in 22 patients receiving a prophylactic dose of LMWH. Group 3 included 27 attempted filter retrievals in 27 patients not receiving therapeutic anticoagulation. Six retrievals were not successful. Five patients were receiving oral anticoagulation with a subtherapeutic INR (median, 1.49; range, 1.16 to 1.69). No anticoagulation medication was administered in 22 patients. In none of the groups were hemorrhagic complications related to the retrieval procedures identified. CONCLUSIONS: These results suggest that retrieval of vena cava filters in anticoagulated patients is safe. Interruption or reversal of anticoagulation for the retrieval of vena cava filters is not indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the incidence of venous thromboembolism (VTE) after removal of retrievable inferior vena cava (IVC) filters. MATERIALS AND METHODS: Retrospective study was conducted of 67 patients who underwent 72 consecutive filter retrievals at a single institution. Data collected included VTE status at the time of filter placement, anticoagulant medications at the time of filter retrieval and afterward, new or recurrent VTE after filter removal, and insertion of subsequent filters. Patient questionnaires were completed in 50 cases, chart review in all patients. RESULTS: At the time of filter placement, 30 patients had documented VTE, 19 had a history of treated VTE, and 23 were at risk for but had neither previous nor present VTE. Mean duration of follow-up after filter removal was 20.6 months +/- 10.9. A total of 52 patients (57 filters) received anticoagulation and/or antiplatelet medications after filter removal. There were two documented episodes of recurrent deep vein thrombosis (2.8% of filters removed), both in patients who had VTE at the time of filter placement and underwent therapeutic anticoagulation at the time of filter removal. One of these patients (1.4% of filters removed) also experienced pulmonary embolism. Of the 23 patients without VTE when the filter was placed, none developed VTE after filter removal. Four patients (5.5% of filters removed) required subsequent permanent filters, three for complications of anticoagulation, one for failure of anticoagulation. CONCLUSIONS: VTE was rare after removal of IVC filters, but was most likely to occur in patients who had VTE at the time of filter placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optional inferior vena cava (IVC) filter prototype was evaluated for safety and long-term retrievability as an initial feasibility study in an animal model. This filter has four centering struts that have the ability to disengage from the filtering cone portion, allowing the legs to slide out of endothelial growth. Retrieval of six filters in three animals was successful up to 27 weeks. There was no substantial filter tilt, migration, or IVC damage. In conclusion, this filter design may help overcome some of the shortcomings in currently approved optional IVC filters, including long-term retrieval difficulties, tilting, or migration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical profiles of stratospheric water vapour measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) with the full resolution mode between September 2002 and March 2004 and retrieved with the IMK/IAA scientific retrieval processor were compared to a number of independent measurements in order to estimate the bias and to validate the existing precision estimates of the MIPAS data. The estimated precision for MIPAS is 5 to 10% in the stratosphere, depending on altitude, latitude, and season. The independent instruments were: the Halogen Occultation Experiment (HALOE), the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Improved Limb Atmospheric Spectrometer-II (ILAS-II), the Polar Ozone and Aerosol Measurement (POAM III) instrument, the Middle Atmospheric Water Vapour Radiometer (MIAWARA), the Michelson Interferometer for Passive Atmospheric Sounding, balloon-borne version (MIPAS-B), the Airborne Microwave Stratospheric Observing System (AMSOS), the Fluorescent Stratospheric Hygrometer for Balloon (FLASH-B), the NOAA frostpoint hygrometer, and the Fast In Situ Hygrometer (FISH). For the in-situ measurements and the ground based, air- and balloon borne remote sensing instruments, the measurements are restricted to central and northern Europe. The comparisons to satellite-borne instruments are predominantly at mid- to high latitudes on both hemispheres. In the stratosphere there is no clear indication of a bias in MIPAS data, because the independent measurements in some cases are drier and in some cases are moister than the MIPAS measurements. Compared to the infrared measurements of MIPAS, measurements in the ultraviolet and visible have a tendency to be high, whereas microwave measurements have a tendency to be low. The results of χ2-based precision validation are somewhat controversial among the comparison estimates. However, for comparison instruments whose error budget also includes errors due to uncertainties in spectrally interfering species and where good coincidences were found, the χ2 values found are in the expected range or even below. This suggests that there is no evidence of systematically underestimated MIPAS random errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Web-scale knowledge retrieval can be enabled by distributed information retrieval, clustering Web clients to a large-scale computing infrastructure for knowledge discovery from Web documents. Based on this infrastructure, we propose to apply semiotic (i.e., sub-syntactical) and inductive (i.e., probabilistic) methods for inferring concept associations in human knowledge. These associations can be combined to form a fuzzy (i.e.,gradual) semantic net representing a map of the knowledge in the Web. Thus, we propose to provide interactive visualizations of these cognitive concept maps to end users, who can browse and search the Web in a human-oriented, visual, and associative interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces a novel vision for further enhanced Internet of Things services. Based on a variety of data (such as location data, ontology-backed search queries, in- and outdoor conditions) the Prometheus framework is intended to support users with helpful recommendations and information preceding a search for context-aware data. Adapted from artificial intelligence concepts, Prometheus proposes user-readjusted answers on umpteen conditions. A number of potential Prometheus framework applications are illustrated. Added value and possible future studies are discussed in the conclusion.