34 resultados para Screening method
Resumo:
BACKGROUND: In recent years, the assessment of the plasma aldosterone-to-renin ratio (ARR) has become an established screening method for the diagnosis of primary aldosteronism. Plasma renin activity (PRA) is usually measured to define ARR although, increasingly, renin concentration alone is often measured in clinical routine. OBJECTIVE: To determine the threshold of ARR using active renin concentration to screen for primary aldosteronism. DESIGN AND PARTICIPANTS: To determine the ARR threshold based on plasma immunoreactive renin concentration (irR), we measured plasma aldosterone concentration (PAC), irR and PRA in 36 hypertensive patients, nine thereof with adrenal adenoma, and compared ARRs calculated from irR and PRA, respectively. SETTING: Single-centre, hypertension clinic in a tertiary care hospital. RESULTS: PRA ranged from 0.41-14.9 ng/ml per h and irR from 1.1-72 ng/l. There was an excellent correlation between PRA and irR (r = 0.98, P < 0.0001) and between ARRPRA and ARRirR (r = 0.96, P < 0.0001). An ARRPRA > 750 pmol/l per ng/ml per h was previously found to be highly predictive of primary aldosteronism because 90% of the corresponding patients failed to suppress PAC upon saline infusion or fludrocortisone. The corresponding threshold value for ARRirR was 150 pmol/ng in our patients. Using these cut-offs, nine subjects had both increased ARRPRA and ARRirR while, in three patients, either ARRPRA or ARRirR were increased. The nine patients with increased ARRPRA and ARRirR also had PAC > 650 pmol/l. Only these patients had adrenal adenomas. CONCLUSIONS: The ARR threshold to screen for primary aldosteronism may be based on measurement of irR. An ARRirR > 150 pmol/ng may indicate primary aldosteronism.
Resumo:
OBJECTIVE: Smuggling dissolved drugs, especially cocaine, in bottled liquids is an ongoing problem at borders. Common fluoroscopy of packages at the border cannot detect contaminated liquids. The objective of our study was to develop an MDCT screening method to detect cocaine-containing vessels that are hidden between uncontaminated ones in a shipment. MATERIALS AND METHODS: Studies were performed on three wine bottles containing cocaine solutions that were confiscated at the Swiss border. Reference values were obtained by scans of different sorts of commercially available wine and aqueous solutions of dissolved sugar. All bottles were scanned using MDCT, and data evaluation was performed by measuring the mean peak of Hounsfield units. To verify the method, simulated testing was performed. RESULTS: Using measurements of the mean peak of Hounsfield units enables the detection of dissolved cocaine in wine bottles in a noninvasive and rapid fashion. Increasing opacity corresponds well with the concentration of dissolved cocaine. Simulated testing showed that it is possible to distinguish between cocaine-contaminated and uncontaminated wine bottles. CONCLUSION: The described method is an efficacious screening method to detect cocaine-contaminated bottles that are hidden between untreated bottles in cargo. The noninvasive examination of cargo allows a questionable delivery to be tracked without arousing the suspicion of the smugglers.
Resumo:
Traumatic lesions of the subcutaneous fatty tissue provide important clues for forensic reconstruction. The interpretation of these patterns requires a precise description and recording of the position and extent of each lesion. During conventional autopsy, this evaluation is performed by dissecting the skin and subcutaneous tissues in successive layers. In this way, depending on the force and type of impact (right angle or tangent), several morphologically distinct stages of fatty tissue damage can be differentiated: perilobular hemorrhage (I), contusion (II), or disintegration (III) of the fat lobuli, and disintegration with development of a subcutaneous cavity (IV). In examples of virtopsy cases showing blunt trauma to the skin and fatty tissue, we analyzed whether these lesions can also be recorded and classified using multislice computed tomography (MSCT) and magnetic resonance imaging (MRI). MSCT has proven to be a valuable screening method to detect the lesions, but MRI is necessary in order to properly differentiate and classify the grade of damage. These noninvasive radiological diagnostic tools can be further developed to play an important role in forensic examinations, in particular when it comes to evaluating living trauma victims.
Resumo:
We describe a microarray based broad-range screening technique for Escherichia coli virulence typing. Gene probes were amplified by PCR from a plasmid bank of characterised E. coli virulence genes and were spotted onto a glass slide to form an array of capture probes. Genomic DNA from E. coli strains which were to be tested for the presence of these virulence gene sequences was labelled with fluorescent cyanine dyes by random amplification and then hybridised against the array of probes. The hybridisation, washing and data analysis conditions were optimised for glass slides, and the applicability of the method for identifying the presence of the virulence genes was determined using reference strains and clinical isolates. It was found to be a sensitive screening method for detecting virulence genes, and a powerful tool for determining the pathotype of E. coli. It will be possible to expand and automate this microarray technique to make it suitable for rapid and reliable diagnostic screening of bacterial isolates.
Resumo:
Bovine mastitis, an inflammatory disease of the mammary gland, is one of the most costly diseases affecting the dairy industry. The treatment and prevention of this disease is linked heavily to the use of antibiotics in agriculture and early detection of the primary pathogen is essential to control the disease. Milk samples (n=67) from cows suffering from mastitis were analyzed for the presence of pathogens using PCR electrospray-ionization mass spectrometry (PCR/ESI-MS) and were compared with standard culture diagnostic methods. Concurrent identification of the primary mastitis pathogens was obtained for 64% of the tested milk samples, whereas divergent results were obtained for 27% of the samples. The PCR/ESI-MS failed to identify some of the primary pathogens in 18% of the samples, but identified other pathogens as well as microorganisms in samples that were negative by culture. The PCR/ESI-MS identified bacteria to the species level as well as yeasts and molds in samples that contained a mixed bacterial culture (9%). The sensitivity of the PCR/ESI-MS for the most common pathogens ranged from 57.1 to 100% and the specificity ranged from 69.8 to 100% using culture as gold standard. The PCR/ESI-MS also revealed the presence of the methicillin-resistant gene mecA in 16.2% of the milk samples, which correlated with the simultaneous detection of staphylococci including Staphylococcus aureus. We demonstrated that PCR/ESI-MS, a more rapid diagnostic platform compared with bacterial culture, has the significant potential to serve as an important screening method in the diagnosis of bovine clinical mastitis and has the capacity to be used in infection control programs for both subclinical and clinical disease.
Resumo:
Intussusceptive capillary growth represents a new principle for microvascular growth as described in the lungs of growing rats. According to this concept, the capillary network expands by the formation of slender transcapillary tissue pillars, which give rise to new vascular meshes. The process was first observed in Mercox casts of the lung microvasculature, which revealed the existence of multiple tiny holes with diameters around 1.5 microns. Consecutive transmission electron microscopic investigation of serial sections demonstrated that the holes corresponded to slender tissue pillars (Burri and Tarek, 1990). The corrosion cast technique thus appears to be an adequate screening method for intussusceptive growth. In the present investigation, Mercox casts of various vascular systems, namely, those of the eye, submandibular gland, heart, liver, stomach, small and large intestine, trachea, kidney, uterus and ovary were prepared from rats aged between 4 and 9 weeks in order to screen them for the existence of the typical tiny holes representing tissue pillars. In all organs investigated, these structures were observed in various locations to a variable degree. They were mainly encountered within dilated vascular segments or at triple or quadruple branching points of the circulation. Even in capillary networks with a three-dimensional arrangement could these pillars be detected. Intussusception thus appears to be a principle of growth appertaining to many vascular systems.
Resumo:
Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.
Resumo:
The major multidrug transporter P-glycoprotein (Pgp) contributes to the barrier function of several tissues and organs, including the brain. In a subpopulation of Collies and seven further dog breeds, a 4 base pair deletion has been described in the Pgp-encoding MDR1 gene. This deletion results in the absence of a functional form of Pgp and loss of its protective function. Severe intoxication with the Pgp substrate ivermectin has been attributed to the genetically determined lack of Pgp. An allele-specific polymerase chain reaction (PCR)-based screening method has been developed to detect the mutant allele and to determine if a dog is homozygous or heterozygous for the mutation. Based on this validation, the allele-specific PCR proved to be a robust, reproducible and specific tool, allowing rapid determination of the MDR1 genotype of dogs of at risk breeds using blood samples or buccal swabs.
Resumo:
A system for screening of nutritional risk is described. It is based on the concept that nutritional support is indicated in patients who are severely ill with increased nutritional requirements, or who are severely undernourished, or who have certain degrees of severity of disease in combination with certain degrees of undernutrition. Degrees of severity of disease and undernutrition were defined as absent, mild, moderate or severe from data sets in a selected number of randomized controlled trials (RCTs) and converted to a numeric score. After completion, the screening system was validated against all published RCTs known to us of nutritional support vs spontaneous intake to investigate whether the screening system could distinguish between trials with a positive outcome and trials with no effect on outcome.
Resumo:
This paper reports an LC-MS/MS method with positive electrospray ionization for the screening of commonly prescribed cardiovascular drugs in human plasma, including compounds with antihypertensive (57), antidiabetic (12), hypolipemiant (5), anticoagulant (2) and platelet anti-aggregation (2) effects. Sample treatment consisted of a simple protein precipitation with MeOH/0.1 M ZnSO₄ (4:1, v/v) solution after the addition of internal standard, followed by evaporation and reconstitution. Analytes separation was performed on a Polar-RP column (150 m x 2 mm, 4 μm) using a gradient elution of 15 min. The MS system was operated in MRM mode, monitoring one quantitation and one confirmation transition for each analyte. The recovery of the protein precipitation step ranged from 50 to 70% for most of the compounds, while some were considerably affected by matrix effects. Since several analytes fulfilled the linearity, accuracy and precision values required by the ICH guidelines, the method proved to be suitable for their quantitative analysis. The limits of quantitation varied from 0.38 to 9.1 μg/L and the limits of detection from 0.12 to 5.34 μg/L. The method showed to be suitable for the detection of plasma samples of patients under cardiovascular treatment with the studied drugs, and for 55 compounds reliable quantitative results could be obtained.
Resumo:
After the discovery of synthetic cannabimimetic substances in 'Spice'-like herbal mixtures marketed as 'incense' or 'plant fertilizer' the active compounds have been declared as controlled substances in several European countries. As expected, a monitoring of new herbal mixtures which continue to appear on the market revealed that shortly after control measures have been taken by legal authorities, other compounds were added to existing mixtures and to new products. Several compounds of the aminoalkylindole type have been detected so far in herbal mixtures but still their consumption cannot be detected by commonly used drug-screening procedures, encouraging drug users to substitute cannabis with those products. There is a increasing demand on the part of police authorities, hospitals and psychiatrists for detection and quantification of synthetic cannabinoids in biological samples originating from psychiatric inpatients, emergency units or assessment of fitness to drive. Therefore, a liquid chromatography-tandem mass spectrometry method after liquid-liquid extraction for the quantitation of JWH-015, JWH-018, JWH-073, JWH-081, JWH 200, JWH-250, WIN 55,212-2 and methanandamide and the detection of JWH-019 and JWH-020 in human serum has been developed and fully validated according to guidelines for forensic toxicological analyses. The method was successfully applied to 101 serum samples from 80 subjects provided by hospitals, detoxification and therapy centers, forensic psychiatric centers and police authorities. Fifty-seven samples or 56.4% were found positive for at least one aminoalkylindole. JWH-019, JWH-020, JWH-200, WIN 55,212-2 and methanandamide were not detected in any of the analyzed samples.
Resumo:
Qualitative assessment of spontaneous motor activity in early infancy is widely used in clinical practice. It enables the description of maturational changes of motor behavior in both healthy infants and infants who are at risk for later neurological impairment. These assessments are, however, time-consuming and are dependent upon professional experience. Therefore, a simple physiological method that describes the complex behavior of spontaneous movements (SMs) in infants would be helpful. In this methodological study, we aimed to determine whether time series of motor acceleration measurements at 40-44 weeks and 50-55 weeks gestational age in healthy infants exhibit fractal-like properties and if this self-affinity of the acceleration signal is sensitive to maturation. Healthy motor state was ensured by General Movement assessment. We assessed statistical persistence in the acceleration time series by calculating the scaling exponent α via detrended fluctuation analysis of the time series. In hand trajectories of SMs in infants we found a mean α value of 1.198 (95 % CI 1.167-1.230) at 40-44 weeks. Alpha changed significantly (p = 0.001) at 50-55 weeks to a mean of 1.102 (1.055-1.149). Complementary multilevel regression analysis confirmed a decreasing trend of α with increasing age. Statistical persistence of fluctuation in hand trajectories of SMs is sensitive to neurological maturation and can be characterized by a simple parameter α in an automated and observer-independent fashion. Future studies including children at risk for neurological impairment should evaluate whether this method could be used as an early clinical screening tool for later neurological compromise.
Resumo:
BACKGROUND: Opportunistic screening for genital chlamydia infection is being introduced in England, but evidence for the effectiveness of this approach is lacking. There are insufficient data about young peoples' use of primary care services to determine the potential coverage of opportunistic screening in comparison with a systematic population-based approach. AIM: To estimate use of primary care services by young men and women; to compare potential coverage of opportunistic chlamydia screening with a systematic postal approach. DESIGN OF STUDY: Population based cross-sectional study. SETTING: Twenty-seven general practices around Bristol and Birmingham. METHOD: A random sample of patients aged 16-24 years were posted a chlamydia screening pack. We collected details of face-to-face consultations from general practice records. Survival and person-time methods were used to estimate the cumulative probability of attending general practice in 1 year and the coverage achieved by opportunistic and systematic postal chlamydia screening. RESULTS: Of 12 973 eligible patients, an estimated 60.4% (95% confidence interval [CI] = 58.3 to 62.5%) of men and 75.3% (73.7 to 76.9%) of women aged 16-24 years attended their practice at least once in a 1-year period. During this period, an estimated 21.3% of patients would not attend their general practice but would be reached by postal screening, 9.2% would not receive a postal invitation but would attend their practice, and 11.8% would be missed by both methods. CONCLUSIONS: Opportunistic and population-based approaches to chlamydia screening would both fail to contact a substantial minority of the target group, if used alone. A pragmatic approach combining both strategies might achieve higher coverage.
Resumo:
BACKGROUND: Adequate assessment of symptoms of patients suffering from environmental illnesses requires appropriate procedures such as psychological and psychiatric diagnostics, medical screening and a thorough analysis of noxious environmental factors. The Basel pilot research project established a multi-methodological assessment procedure that meets these criteria. However, an exhaustive three-fold analysis is very costly in terms of both equipment and personnel, and hence the need for a heuristic approach and pre-screening persists. METHOD: The three-fold diagnostic approach was preceded by a structured psychodynamic interview; the findings were used to construct a new profile of the patient's interactional behaviour (IB) in conjunction with the interviewer's countertransference. The extent to which this new profile could predict the results of the multi-method assessment was then assessed. RESULTS: A low level of IB on the part of the patient significantly predicted the degree of stress and the extent of the psychiatric diagnosis, including personality disorders. A negative IB was associated with negative personality traits. Furthermore, a high level of IB implied more medical, but not more environmental, findings which could plausibly be related to the patient's complaints. CONCLUSIONS: Assessment of patients' IB in conjunction with one's own countertransference is very helpful as a preliminary heuristic approach and may lead to consequences for treatment and therapy. Therefore, the training provided for experts who deal with patients suffering from environment-related complaints should place more specific emphasis on assessing patients' behaviour and on incorporating information gathered from countertransference. Nevertheless, an interdisciplinary assessment including medical, psychological/psychiatric, and environmental expertise remains mandatory for adequate and satisfactory diagnosis of patients with environment-related complaints.
Resumo:
BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.