24 resultados para Schelling, Friedrich Wilhelm Joseph von


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 27-year-old Caucasian (gravida 2 para 1) presented in week 16 of her twin pregnancy with worsening of hyperandrogenic symptoms. In week 17, she developed an acute abdomen due to a twisted, incarcerated right ovary, which was surgically removed. Histological analysis revealed a diffuse steroid cell hyperplasia. Postsurgery testosterone levels fell temporarily within normal limits, diminishing the hyperandrogenic symptoms. Over time androgen levels rose again slowly above normal values with clinical worsening of hirsutism. In the 32nd week of gestation, a cesarean section of two healthy female infants was necessary due to the development of preeclampsia. An ovarian biopsy revealed again the picture of hyperreactio luteinalis. Postpartum peripheral hormone levels fell within normal limits and the hyperandrogenic symptoms subsided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: In humans and other animals, open, expansive postures (compared to contracted postures) are evolutionary developed expressions of power and have been shown to cause neuroendocrine and behavioral changes (Carney, Cuddy, & Yap, 2010). In the present study we aimed to investigate whether power postures have a bearing on the participant’s facial appearance and whether others are able to distinguish faces after “high power posing” from faces after “low power posing”. Methods: 16 models were photographed 4-5 minutes after having adopted high and low power postures. Two different high power and two different low power postures were held for 2 minutes each. Power-posing sessions were performed on two consecutive days. High and low power photographs of each model were paired and an independent sample of 100 participants were asked to pick the more dominant and the more likeable face of each pair. Results: Photographs that were taken after adopting high power postures were chosen significantly more often as being more dominant looking. There was no preference when asked to choose the more likeable photograph (chance level). A further independent sample rated each photograph for head tilt, making it unlikely that dominance ratings were caused merely by the posture of the head. Consistently, facial width-to-height ratio did not differ between faces after high and low power posing. Conclusions: Postures associated with high power affect facial appearance, leading to a more dominant looking face. This finding may have implications for everyday life, for instance when a dominant appearance is needed.