50 resultados para Safe


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ventral hernia repair is increasingly performed by laparoscopic means since the introduction of dual-layer meshes. This study aimed to compare the early complications and cost effectiveness of open hernia repair with those associated with laparoscopic repair. METHODS: Open ventral hernia repair was performed for 92 consecutive patients using a Vypro mesh, followed by laparoscopic repair for 49 consecutive patients using a Parietene composite mesh. RESULTS: The rate of surgical-site infections was significantly higher with open ventral hernia repair (13 vs 1; p = 0.03). The median length of hospital stay was significantly shorter with laparoscopic surgery (7 vs 6 days; p = 0.02). For laparoscopic repair, the direct operative costs were higher (2,314 vs 2,853 euros; p = 0.03), and the overall hospital costs were lower (9,787 vs 7,654 euros; p = 0.02). CONCLUSIONS: Laparoscopic ventral hernia repair leads to fewer surgical-site infections and a shorter hospital stay than open repair. Despite increased operative costs, overall hospital costs are lowered by laparoscopic ventral hernia repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Little is known on the performance of newly initiated carotid artery stenting (CAS) programs. The safety of the procedure is being questioned following the publication of the EVA-3S trial, a study criticized for the limited interventional experience required to enroll patients. METHODS: Within a newly started academic CAS program, patient data and outcomes were collected prospectively. The outcomes of the first 100 consecutive patients treated are reported. A CAS-fellowship-trained interventionalist was involved in all procedures. All patients underwent clinical assessment by a neurologist before and after the procedure, and serial ECG and cardiac enzymes were routinely obtained. Primary outcome measures included 30-day major adverse events (MAE), defined as death, stroke, or myocardial infarction, while on follow-up deaths and ipsilateral strokes were added. RESULTS: Between July 2003 and November 2006, 92 patients had a single internal carotid artery treated, while 7 underwent staged bilateral CAS. In one patient, the procedure was aborted prior to lesion treatment. The 30-day MAE rate per procedure was 1.9% (one major and one minor stroke). By a mean follow-up of 16 months (range 2-42 months), one patient had died of refractory heart failure, while one patient had a minor ipsilateral stroke and three had minor contralateral strokes, corresponding to total MAE per patient of 4%. The rate of any stroke or death was 7%. The rate of restenosis >or=50% per lesion by ultrasound was 3.8%. CONCLUSION: This single center experience suggests that it is safe to start a CAS program following dedicated fellowship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report our experience with the successful removal of visible tension-free vaginal tape (TVT) by standard transurethral electroresection, as intravesical tape erosion after TVT is a rare complication, and removal can be challenging, with few cases reported. PATIENTS AND METHODS: Five patients presenting with TVT erosion into the bladder were treated at our institutions from December 2004 to July 2007; all had standard transurethral electroresection. Their records were reviewed retrospectively to retrieve data on presenting symptoms, diagnostic tests, surgical procedures and outcomes. RESULTS: The median (range) interval between the TVT procedure and the onset of symptoms was 17 (1-32) months. The predominant symptoms were painful micturition, recurrent urinary tract infection (UTI), urgency and urge incontinence. There were no complications during surgery. The storage symptoms and UTI resolved completely after removing the eroded mesh in all but one patient. Cystoscopy at 1 month after surgery showed complete healing of the bladder mucosa. CONCLUSION: Although TVT erosion into the bladder is rare, persistent symptoms, particularly recurrent UTIs, must raise some suspicion for this condition. Standard transurethral electroresection seems to be a safe, simple, minimally invasive and successful treatment option for TVT removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strictures are a frequent complication of eosinophilic esophagitis. The efficacy and safety of topical corticosteroids and of dilation of eosinophilic esophagitis-associated strictures have not yet been thoroughly clarified. We present a retrospective analysis of 10 adult patients with eosinophilic esophagitis who had symptomatic esophageal stenosis that was unresponsive to topical corticosteroids, and who were treated using bougienage. Eight patients had one single stricture, one patient had two, and another had three strictures; mean stricture length was 2.1 cm (range 1 - 6 cm). Bougienage led to prompt symptom relief. Apart from transient postprocedural odynophagia, no severe complications occurred. During the follow-up (mean 6 months; range 2 - 11 months), all patients enjoyed sustained treatment response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Current guidelines for the management of acute coronary syndrome clearly recommend that clopidogrel should be started before diagnostic coronary angiography. If patients undergo coronary artery bypass grafting (CABG) early after clopidogrel loading or during continued exposure, it seems reasonable to expect an increase in bleeding complications. RECENT FINDINGS: Earlier studies may have overestimated the risk of bleeding in patient undergoing CABG with prior clopidogrel exposure (5-10-fold increase). Some conflicting results are reported in literature. As reexploration because of excessive bleeding is concerned, a two to three-fold increase must be expected, which is demonstrated in actual trials properly matched to confounding factors. Discontinuation of clopidogrel for 5-7 days prior to urgent CABG as recommended by guidelines is not well adopted in clinical practice for several reasons. SUMMARY: There is a moderately elevated risk of bleeding complications after CABG due to prior clopidogrel exposure alone. However, in clinical practice this risk is added often to patients who carry already elevated surgical risks (urgent procedures, worse coronary anatomy, history of previous myocardial infarction and prior percutaneous intervention), and after bleeding complications singular patients may suffer from consecutive adverse outcome. Cessation of clopidogrel in patients before CABG clearly prolongs hospitalization time and has an estimated 1% risk of coronary events during the waiting period. Risk and benefit have to be balanced in every individual case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Code executed in a fully reflective system switches back and forth between application and interpreter code. These two states can be seen as contexts in which an expression is evaluated. Current language implementations obtain reflective capabilities by exposing objects to the interpreter. However, in doing so these systems break the encapsulation of the application objects. In this paper we propose safe reflection through polymorphism, \ie by unifying the interface and ensuring the encapsulation of objects from both the interpreter and application context. We demonstrate a \emphhomogeneous system that defines the execution semantics in terms of itself, thus enforcing that encapsulation is not broken.